COMPARISON OF INFRARED AND HELIUM-NEON LASERS IN THE MEASUREMENT OF BLOOD-FLOW IN HUMAN SKIN BY THE LASER-DOPPLER TECHNIQUE

被引:0
|
作者
COULSON, ML [1 ]
HAYES, NA [1 ]
FOREMAN, JC [1 ]
机构
[1] UNIV LONDON UNIV COLL,DEPT PHARMACOL,GOWER ST,LONDON WC1E 6BT,ENGLAND
来源
SKIN PHARMACOLOGY | 1992年 / 5卷 / 02期
关键词
LASER-DOPPLER; BLOOD FLOW; HUMAN SKIN; HISTAMINE;
D O I
暂无
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Histamine-induced changes in blood flow in normal human skin were assessed by laser-Doppler velocimetry using 2 lasers of different wavelengths: 780 nm infrared and 633 nm helium-neon. The visible flare response in skin was also measured by planimetry. Laser-Doppler velocimetry was shown to detect both the magnitude of the change in blood flow caused by histamine and also the extent of the changes in the skin. Both parameters were related to the dose of histamine, which ranged between 25 and 750 pmol/site. There was good correlation between the magnitude of the histamine-induced blood flow change and the extent of the response. The flare induced by histamine and measured by planimetry was similar in extent to the blood flow change, recorded by laser-Doppler velocimetry. No difference in either the magnitude or the extent of blood flow changes in response to histamine, as measured by laser-Doppler velocimetry, were found when lasers of different wavelengths were used.
引用
收藏
页码:81 / 86
页数:6
相关论文
共 50 条
  • [41] LASER DOPPLER SKIN BLOOD-FLOW IN PREGNANCY
    ORBO, A
    ACTA PHYSIOLOGICA SCANDINAVICA, 1985, 124 : 426 - 426
  • [42] Reliability of Skin Blood Flow Measures by Laser-Doppler Flowmetry
    Herron, Robert
    Carter, Stephen
    Collins, Ann
    Leatherwood, Matthew
    FASEB JOURNAL, 2015, 29
  • [43] MONITORING OF CORTICAL BLOOD-FLOW IN HUMAN EPILEPTIC FOCI USING LASER-DOPPLER FLOWMETRY
    RONNEENGSTROM, E
    CARLSON, H
    BLOM, S
    FLINK, R
    GAZELIUS, B
    SPANNARE, B
    HILLERED, L
    JOURNAL OF EPILEPSY, 1993, 6 (03): : 145 - 151
  • [44] COMPARISON OF SKIN BLOOD-FLOW IN MAN MEASURED BY NEAR-INFRARED LASER DOPPLER FLOWMETER AND BY PLETHYSMOGRAPHY
    BICKERSTAFF, M
    WARD, J
    JOURNAL OF PHYSIOLOGY-LONDON, 1992, 446 : P579 - P579
  • [45] MEASUREMENT OF VELOCITY PROFILES IN SIMULATED BLOOD BY LASER-DOPPLER TECHNIQUE
    KREID, DK
    GOLDSTEI.RJ
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1970, 15 (11): : 1539 - &
  • [46] CONTINUOUS MEASUREMENT OF CEREBRAL CORTICAL BLOOD-FLOW BY LASER-DOPPLER FLOWMETRY IN A RAT STROKE MODEL
    DIRNAGL, U
    KAPLAN, B
    JACEWICZ, M
    PULSINELLI, W
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1989, 9 (05): : 589 - 596
  • [47] MEASUREMENT OF SKELETAL-MUSCLE BLOOD-FLOW IN BULLET WOUNDING WITH A NEW LASER-DOPPLER FLOWMETER
    OBERG, PA
    NILSSON, GE
    TENLAND, T
    HOLMSTROM, A
    LEWIS, DH
    MICROVASCULAR RESEARCH, 1979, 18 (02) : 298 - 298
  • [48] LASER-DOPPLER MEASUREMENT OF DIGITAL BLOOD-FLOW REGULATION IN NORMALS AND IN PATIENTS WITH RAYNAUDS-PHENOMENON
    KRISTENSEN, JK
    ENGELHART, M
    NIELSEN, T
    ACTA DERMATO-VENEREOLOGICA, 1983, 63 (01) : 43 - 47
  • [49] LASER DOPPLER MEASUREMENT OF CUTANEOUS BLOOD-FLOW
    HOLLOWAY, GA
    WATKINS, DW
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1977, 69 (03) : 306 - 309
  • [50] LASER-DOPPLER FLOWMETRY FOR ESTIMATION OF BONE BLOOD-FLOW - STUDIES OF REPRODUCIBILITY AND CORRELATION WITH MICROSPHERE TECHNIQUE
    LAUSTEN, GS
    KIAER, T
    DAHL, B
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1993, 11 (04) : 573 - 580