Calibration of Cylindrical NaI(Tl) Detector Using Different Perpendicular Radioactive Cylindrical Sources

被引:0
|
作者
Badawi, Mohamed. S. [1 ]
机构
[1] Alexandria Univ, Fac Sci, Phys Dept, Alexandria 21511, Egypt
来源
关键词
Full-energy peak efficiency; Scintillation detector; Efficiency transfer;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Environmental samples containing some contaminated samples of a wide variety of characteristics are routinely analyzed using gamma-ray detectors. In this work the full energy peak efficiency of NaI(Tl) scintillation detectors 2"x2" and 3"x3" inches have been calculated experimentally by using perpendicular radioactive cylindrical sources and theoretically by applying an analytical efficiency transfer expression. This expression was based on including the ratio of the sourceto- detector effective solid angle. Measurements were made using the perpendicular cylindrical vials filled with 152Eu solution. The Calibration process covers a wide energy range starting from 121 up to 1408 keV. In addition, the self-attenuation factor was estimated by using the linear attenuation factor of the assayed source material and the geometrical configuration of the assay set-up at low source-detector distance. A remarkable agreement between measured and calculated efficiency values was observed.
引用
收藏
页码:67 / 75
页数:9
相关论文
共 50 条
  • [41] Effects of gamma irradiation on some chemicals using an NaI (Tl) detector
    Bhosale, R. R.
    Gaikwad, D. K.
    Pawar, P. P.
    Rode, M. N.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2016, 171 (5-6): : 398 - 407
  • [42] A New Approach for NaI(Tl) Detector Efficiency Calibration Using 41Ar Radionuclide for Air Exhaust Systems
    Farasat, Mahsa
    Zagni, Federico
    Pompignoli, Lorenzo
    Cirrone, G. A. Pablo
    Scherer, Ulrich W.
    Strigari, Lidia
    Mostacci, Domiziano
    NUCLEAR SCIENCE AND ENGINEERING, 2023, 197 (09) : 2317 - 2326
  • [43] Energy calibration of the NaI(Tl) calorimeter of the SND detector using e+e-→e+e- events
    Achasov, MN
    Bukin, DA
    Dimova, TV
    Druzhinin, VP
    Golubev, VB
    Ivanchenko, VN
    Korol, AA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 411 (2-3): : 337 - 342
  • [44] Development and calibration of on-line monitoring sensor for Marine radioactivity based on NaI(Tl) detector
    Liu Dongyan
    Zhang Yingying
    Zou Bo
    Yuan Da
    2018 CHINESE AUTOMATION CONGRESS (CAC), 2018, : 1973 - 1976
  • [45] An empirical formula for the efficiency detection of Ge detectors for cylindrical radioactive sources
    Alfassi, Z. B.
    Groppi, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 574 (02): : 280 - 284
  • [46] Development of a radioactive waste measurement system using arrayed NaI(Tl) detectors
    Yang, Guang
    Shi, Rui
    Wang, Zhou
    Tuo, Xianguo
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2024, 85 (11) : 883 - 889
  • [47] CALCULATED EFFICIENCIES OF NAI (T1) SCINTILLATION CRYSTALS FOR AQUEOUS CYLINDRICAL SOURCES
    VERHEIJKE, ML
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1964, 15 (09): : 559 - &
  • [48] Calibration of a time-resolved hard-x-ray detector using radioactive sources
    Stoeckl, C.
    Theobald, W.
    Regan, S. P.
    Romanofsky, M. H.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [49] EXPERIMENTAL DETERMINATION OF THE PHOTOFRACTION OF A CYLINDRICAL 4X6 NAI(TI) SCINTILLATION DETECTOR
    WEITKAMP, C
    NUCLEAR INSTRUMENTS & METHODS, 1963, 23 (01): : 10 - 12
  • [50] Estimation of NaI(Tl) detector reflector thickness and Geant4-based full-energy-peak efficiency calibration for extended sources
    Mansoor, Shahid
    Satti, Khizar Hayat
    Malik, Azhar Hussain
    Ahmad, Asrar
    Siddique, Muhammad Tariq
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2025,