Calibration of Cylindrical NaI(Tl) Detector Using Different Perpendicular Radioactive Cylindrical Sources

被引:0
|
作者
Badawi, Mohamed. S. [1 ]
机构
[1] Alexandria Univ, Fac Sci, Phys Dept, Alexandria 21511, Egypt
来源
关键词
Full-energy peak efficiency; Scintillation detector; Efficiency transfer;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Environmental samples containing some contaminated samples of a wide variety of characteristics are routinely analyzed using gamma-ray detectors. In this work the full energy peak efficiency of NaI(Tl) scintillation detectors 2"x2" and 3"x3" inches have been calculated experimentally by using perpendicular radioactive cylindrical sources and theoretically by applying an analytical efficiency transfer expression. This expression was based on including the ratio of the sourceto- detector effective solid angle. Measurements were made using the perpendicular cylindrical vials filled with 152Eu solution. The Calibration process covers a wide energy range starting from 121 up to 1408 keV. In addition, the self-attenuation factor was estimated by using the linear attenuation factor of the assayed source material and the geometrical configuration of the assay set-up at low source-detector distance. A remarkable agreement between measured and calculated efficiency values was observed.
引用
收藏
页码:67 / 75
页数:9
相关论文
共 50 条
  • [21] A method to calculate the gamma ray detection efficiency of a cylindrical NaI (Tl) crystal
    Ahmadi, S.
    Ashrafi, S.
    Yazdansetad, F.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [22] An analytical calculation of the peak efficiency for cylindrical sources perpendicular to the detector axis in gamma-ray spectrometry
    Aguiar, Julio C.
    APPLIED RADIATION AND ISOTOPES, 2008, 66 (08) : 1123 - 1127
  • [23] Efficiency calibration and coincidence summing correction for a 4πNaI(Tl detector array
    Byun, SH
    Prestwich, WV
    Chin, K
    McNeill, FE
    Chettle, DR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 535 (03): : 674 - 685
  • [24] Radioactive source strength effect on gamma radiation monitoring with a NaI (Tl) scintillation detector
    Yeboah, E.
    Yakovlev, G. A.
    Smirnov, S. V.
    Yakovleva, V. S.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (05)
  • [25] EVALUATION OF TOTAL ABSOLUTE EFFICIENCIES FOR NAI(TL) CYLINDRICAL AND WELL-TYPE CRYSTALS
    IONESCU, C
    REVUE ROUMAINE DE PHYSIQUE, 1969, 14 (10): : 1135 - &
  • [26] New numerical evaluation of parallelepiped NaI(Tl) detector geometrical and total efficiencies using extended sources
    Noureddeen, S. F.
    Abbas, M. I.
    RADIOPROTECTION, 2017, 52 (04) : 265 - 271
  • [27] Direct mathematical calculation of the photopeak efficiency for gamma rays in cylindrical NaI(Tl) detectors
    Abbas, MI
    Bassiouni, M
    EXPERIMENTAL NUCLEAR PHYSICS IN EUROPE: ENPE 99: FACING THE NEXT MILLENNIUM, 1999, 495 : 268 - 272
  • [28] Analytical-numerical formula for estimating the characteristics of a cylindrical NaI(Tl) gamma-ray detector with a side-through hole
    Thabet, Abouzeid A.
    Badawi, Mohamed S.
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (10) : 3795 - 3802
  • [29] The project of using the SND NaI(Tl) calorimeter as an antineutron detector
    Bukin, A. D.
    Bukin, D. A.
    Golublev, V. B.
    Serednyakov, S. I.
    Skovpen, K. Yu.
    Usov, Yu. V.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 598 (01): : 264 - 265
  • [30] THE CALIBRATION OF A NAI(TL) SCINTILLATION SPECTROMETER USING A PHOTON MONOCHROMATOR
    HAGUE, JF
    RAND, RE
    NUCLEAR INSTRUMENTS & METHODS, 1964, 31 (01): : 157 - 168