A New Approach for NaI(Tl) Detector Efficiency Calibration Using 41Ar Radionuclide for Air Exhaust Systems

被引:0
|
作者
Farasat, Mahsa [1 ,2 ,3 ,4 ]
Zagni, Federico [5 ]
Pompignoli, Lorenzo [1 ]
Cirrone, G. A. Pablo [2 ,3 ]
Scherer, Ulrich W. [4 ]
Strigari, Lidia [5 ]
Mostacci, Domiziano [6 ]
机构
[1] Tema Sinergie SpA, Faenza, Italy
[2] Natl Inst Nucl Phys INFN LNS, Catania, Italy
[3] UniCT, DFA, Catania, Italy
[4] Hsch Mannheim Univ Appl Sci, Inst Phys Chem & Radiochem, Mannheim, Germany
[5] IRCCS Azienda Osped Univ Bologna, Dept Med Phys, Bologna, Italy
[6] Univ Bologna, Montecuccolino Nucl Enginering Lab, DIN, Bologna, Italy
关键词
Waste management system; positron emission tomography; full peak efficiency calibration; Monte Carlo simulation; air activation in cyclotron bunkers; MONTE-CARLO;
D O I
10.1080/00295639.2022.2164148
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Argon-41 is an essential gaseous radionuclide that must be monitored in gaseous effluents from nuclear facilities. Therefore, a precise evaluation of Ar-41 activity is highly desired. Gamma spectroscopy with a NaI(Tl) scintillation detector coupled with a multichannel analyzer (MCA) is one of the widely used techniques for the identification and activity measurements of radioisotopes. However, the efficiency calibration of these kinds of monitoring systems highly depends on the source-detector geometry, and a large amount of uncertainty may complicate the calibration. This paper presents the evaluation of the full peak efficiency of a 2 x 2-in. NaI(Tl) scintillation detector coupled with a stable MCA for a Ar-41 source with 1293.5 keV energy in two different source-detector geometries, duct and Marinelli beaker, using the FLUKA code. A new experimental technique is considered to produce Ar-41 in a controlled geometry, like a Marinelli beaker, through neutron irradiation of natural argon inside a cyclotron bunker. The simulation data were compared with the experimental results for Marinelli beaker geometry, and the ratio was evaluated as 0.99 +/- 0.07. The ratio was considered a scaling factor for the final efficiency calibration of duct geometry.
引用
收藏
页码:2317 / 2326
页数:10
相关论文
共 7 条
  • [1] Calibration for 41Ar of radiation detectors for air exhaust systems
    Zagni, F.
    Vichi, S.
    Pantalone, G.
    Cabitza, V.
    Sabba, N.
    Moretti, E.
    D'Arienzo, M.
    Fanti, S.
    Strigari, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S163 - S163
  • [2] Activity determination of 41Ar using efficiency extrapolation method and 4πβ(PS)-4πγ(NaI) coincidence system
    Xie, Feng
    Li, Xuesong
    Dai, Yihua
    Jiang, Wengang
    He, Xiaobing
    Yu, Gongshuo
    Ni, Jianzhong
    APPLIED RADIATION AND ISOTOPES, 2015, 97 : 8 - 11
  • [3] Calibration of a single hexagonal NaI(Tl) detector using a new numerical method based on the efficiency transfer method
    Abbas, Mahmoud I.
    Badawi, M. S.
    Ruskov, I. N.
    El-Khatib, A. M.
    Grozdanov, D. N.
    Thabet, A. A.
    Kopatch, Yu. N.
    Gouda, M. M.
    Skoy, V. R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 771 : 110 - 114
  • [4] A new experimental procedure for determination of photoelectric efficiency of a NaI(Tl) detector used for nuclear medicine liquid waste monitoring with traceability to a reference standard radionuclide calibrator
    Ceccatelli, A.
    Campanella, F.
    Ciofetta, G.
    Marracino, F. M.
    Cannata, V.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (02) : 275 - 279
  • [5] New analytical approach to calculate the detector efficiencies of NaI(Tl) using coaxial and off-axis rectangular and parallelepiped sources
    Hamzawy, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 768 : 164 - 169
  • [6] A New Approach for the Determination of Dose Rate and Radioactivity for Detected Gamma Nuclides Using an Environmental Radiation Monitor Based on an NaI(Tl) Detector
    Ji, Young-Yong
    Kim, Chang-Jong
    Lim, Kyo-Sun
    Lee, Wanno
    Chang, Hyon-Sock
    Chung, Kun Ho
    HEALTH PHYSICS, 2017, 113 (04): : 304 - 314
  • [7] A new NaI(Tl) four-detector layout for field contamination assessment using artificial neural networks and the Monte Carlo method for system calibration
    Moreira, M. C. F.
    Conti, C. C.
    Schirru, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 621 (1-3): : 302 - 309