ALGORITHM FOR CRYSTAL ALIGNMENT WITH A 2-AXIS GONIOMETER

被引:1
|
作者
MILSTEIN, JB
机构
[1] Department of Electrical Engineering, University of Lowell, Lowell, MA 01854, One University Avenue
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1990年 / 61卷 / 10期
关键词
D O I
10.1063/1.1141841
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An algorithm for determining the necessary angular corrections to bring a selected direction in a crystal into alignment using a two-axis goniometer is presented. The procedure requires the measurement of the specimen-to-film distance, the x and y (or polar) coordinates of the reflection of interest, and the recording of the values of the rotation and oscillation axis settings used to make the back-reflection photograph. A solution in closed form may then be calculated and checked for feasibility, given the physical oscillation limits of the goniometer.
引用
收藏
页码:2581 / 2584
页数:4
相关论文
共 50 条
  • [41] Thermal dynamics of 2-axis electrothermal MEMS micromirrors
    Donnachie, Mark
    Uttamchandani, Deepak
    Bauer, Ralf
    2019 INTERNATIONAL CONFERENCE ON OPTICAL MEMS AND NANOPHOTONICS (OMN), 2019, : 228 - 229
  • [42] Scanning OCT endoscope with 2-axis magnetic micromirror
    Bernstein, Jonathan J.
    Lee, Tom W.
    Rogomentich, Fran J.
    Bancu, Mirela G.
    Kim, Ki H.
    Maguluri, Gopi
    Bouma, Brett E.
    DeBoer, Johannes F.
    ENDOSCOPIC MICROSCOPY II, 2007, 6432
  • [43] FLUIDIC 2-AXIS TIME MODULATED POSITION SENSOR
    DECOTIIS, CJ
    WEBER, RE
    AUTOMATICA, 1970, 6 (04) : 505 - &
  • [44] HUMAN PERFORMANCE IN SINGLE AND 2-AXIS TRACKING SYSTEMS
    TODOSIEV, EP
    ROSE, RE
    SUMMERS, LG
    IEEE TRANSACTIONS ON HUMAN FACTORS IN ELECTRONICS, 1967, HFE8 (02): : 125 - &
  • [45] STABILITY OF SYNCHRONOUS MACHINES WITH 2-AXIS EXCITATION SYSTEMS
    MURTHI, MR
    WILLIAMS, D
    HOGG, BW
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1970, 117 (09): : 1799 - &
  • [46] 2-axis detection resonant accelerometer based on rigidity change
    Tabata, O
    Yamamoto, T
    MICROMACHINED DEVICES AND COMPONENTS IV, 1998, 3514 : 210 - 216
  • [47] Extraction and optimisation of cutting conditions for 2 1/2-axis milling
    Yan, X
    Shirase, K
    Hirao, M
    Yasui, T
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2000, 16 (10): : 695 - 699
  • [48] INVESTIGATION OF SPHERICAL HYDROSTATIC GAS BEARING FOR 2-AXIS GYROS
    ROOD, L
    JOURNAL OF LUBRICATION TECHNOLOGY, 1971, 93 (01): : 79 - &
  • [49] INVESTIGATION OF ORIENTATED CONDITIONS OF GENERATION OF THE STATIONARY 2-AXIS DYNAMO
    KROPACHEV, EP
    GORSHKOV, SN
    GEOMAGNETIZM I AERONOMIYA, 1982, 22 (06): : 1032 - 1033
  • [50] ANALYSIS OF PRECOGNITIVE DYNAMICS IN A 2-AXIS PURSUIT TRACKING TASK
    AOKI, T
    YAJIMA, K
    AOKI, K
    TANAKA, H
    KINOSHITA, S
    YAMANOI, N
    FURUKAWA, T
    ERGONOMICS, 1982, 25 (06) : 491 - 491