ALGORITHM FOR CRYSTAL ALIGNMENT WITH A 2-AXIS GONIOMETER

被引:1
|
作者
MILSTEIN, JB
机构
[1] Department of Electrical Engineering, University of Lowell, Lowell, MA 01854, One University Avenue
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1990年 / 61卷 / 10期
关键词
D O I
10.1063/1.1141841
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An algorithm for determining the necessary angular corrections to bring a selected direction in a crystal into alignment using a two-axis goniometer is presented. The procedure requires the measurement of the specimen-to-film distance, the x and y (or polar) coordinates of the reflection of interest, and the recording of the values of the rotation and oscillation axis settings used to make the back-reflection photograph. A solution in closed form may then be calculated and checked for feasibility, given the physical oscillation limits of the goniometer.
引用
收藏
页码:2581 / 2584
页数:4
相关论文
共 50 条
  • [1] PRECISE SPECIMEN MANIPULATOR FOR A LEED CAMERA WITH A 2-AXIS GONIOMETER
    HOEHMAN, F
    LYNCH, DF
    VACUUM, 1972, 22 (03) : 107 - &
  • [2] RHEUMATOID-ARTHRITIS - A 2-AXIS GONIOMETER TO MEASURE METACARPOPHALANGEAL LAXITY
    HASSELKUS, BR
    KSHEPAKARAN, KK
    HOUGE, JC
    PLAUTZ, KA
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1981, 62 (03): : 137 - 139
  • [3] LOW-TEMPERATURE 2-AXIS GONIOMETER WITH ACCURATE TEMPERATURE CONTROL
    HERZOG, R
    EVETTS, JE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (11): : 3574 - 3576
  • [4] A 2-AXIS CRYSTAL NEUTRON SPECTROMETER
    CHIKOBAV.VS
    DOIDZHAS.GI
    ABESADZE, PD
    NAVASARD.SA
    SHARABID.TI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1966, (04): : 808 - &
  • [5] A 2-AXIS MICROPOSITIONER FOR OPTICAL-FIBER ALIGNMENT
    KNIGHT, JD
    WEST, JN
    HEWLETT-PACKARD JOURNAL, 1993, 44 (06): : 80 - 84
  • [6] CRYSTAL ALIGNMENT ON THE WEISSENBERG GONIOMETER
    DRAGSDORF, RD
    ACTA CRYSTALLOGRAPHICA, 1953, 6 (02): : 220 - 220
  • [7] Tilt compensation algorithm for 2-axis magnetic compass
    Cho, SY
    Park, CG
    ELECTRONICS LETTERS, 2003, 39 (22) : 1589 - 1590
  • [8] A LIQUID HE COOLED 2-AXIS GONIOMETER FOR CHANNELING MEASUREMENTS DOWN TO 5K
    KAUFMANN, R
    GEERK, J
    RATZEL, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 205 (1-2): : 293 - 297
  • [9] 2-AXIS GONIOMETER FOR REFLECTIVITY MEASUREMENTS OF X-RAY DIFFRACTORS USED IN FUSION-RESEARCH
    PEACOCK, NJ
    BARNSLEY, R
    PATEL, A
    OMULLANE, M
    SINGLETON, M
    ASHALL, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02): : 1175 - 1179
  • [10] CRYSTAL MOSAIC SPREAD MEASUREMENT BY MEANS OF A NEUTRON 2-AXIS SPECTROMETER
    RAUCH, H
    ATOMKERNENERGIE, 1967, 12 (11-1): : 395 - &