IMPRINTING ZEOLITE-MODIFIED GLASSY CARBON AS A VOLTAMMETRIC SENSOR FOR URIC ACID

被引:7
|
作者
Khasanah, Miratul [1 ]
Harsini, Muji [1 ]
Widati, Alfa Akustia [1 ]
机构
[1] Airlangga Univ, Fac Sci & Technol, Dept Chem, Kampus C Unair, Surabaya 60115, Indonesia
关键词
sensor; uric acid; voltammetry; imprinting zeolite; glassy carbon;
D O I
10.22146/ijc.21292
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Development of the uric acid sensor through coating of glassy carbon ( GC) electrode with imprinting zeolite (IZ) was carried out. Zeolite was synthesized by mixing TEOS, TBOT, TPAOH, and water followed by hydrothermal process. Zeolite was molded together with uric acid to produce IZ. The deposition potential of IZ and uric acid to the GC surface was -0.6 V during 150 sec with addition of KNO3 0.02 M as supporting electrolyte. The method gives linearity of 0.9834 (concentration 5.6x10(-9)M - 2.8x10(-8) M), precision 1.89 - 7.65%, sensitivity 0.33 mu A/nM/cm(2), limit of detection 5.9x10(-9) M, and accuracy 96.26 +/- 0.55% (n = 5). The developed sensor showed a high selectivity toward uric acid. The presence of ascorbic acid, creatine, and creatinine with an equal concentration with uric acid did not interfere on the uric acid analysis.
引用
收藏
页码:108 / 113
页数:6
相关论文
共 50 条
  • [41] Voltammetric sensor for trichloroacetic acid using a glassy carbon electrode modified with Au@Ag nanorods and hemoglobin
    Dongping Qian
    Weibo Li
    Fangting Chen
    Ying Huang
    Ning Bao
    Haiying Gu
    Chunmei Yu
    [J]. Microchimica Acta, 2017, 184 : 1977 - 1985
  • [42] A New Voltammetric Sensor Based on a Glassy Carbon Electrode Modified with 8-Hydroxyquinoline-5-sulfonic Acid
    Brunetti, Barbara
    Desimoni, Elio
    [J]. ELECTROANALYSIS, 2011, 23 (05) : 1116 - 1122
  • [43] A zeolite modified carbon paste electrode as useful sensor for voltammetric determination of acetaminophen
    Ahmadpour-Mobarakeh, Leila
    Nezamzadeh-Ejhieh, Alireza
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 49 : 493 - 499
  • [44] Fabrication of a fast, simple and sensitive voltammetric sensor for the simultaneous determination of 4-aminohippuric acid and uric acid using a functionalized multi-walled carbon nanotube modified glassy carbon electrode
    Raoof, Jahan Bakhsh
    Ojani, Reza
    Baghayeri, Mehdi
    Ahmadi, Farzaneh
    [J]. ANALYTICAL METHODS, 2012, 4 (06) : 1825 - 1832
  • [45] Zeolite-modified carbon paste electrode for selective monitoring of dopamine
    New Mexico State Univ, Las Cruces, United States
    [J]. J Electroanal Chem, 1-2 (183-187):
  • [46] Zeolite-modified carbon paste electrode for selective monitoring of dopamine
    Wang, J
    Walcarius, A
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 407 (1-2): : 183 - 187
  • [47] EFFECTS OF SOLUTION PH ON THE VOLTAMMETRIC BEHAVIOR OF FERROUS FERRIC IONS AT ZEOLITE-MODIFIED ELECTRODES
    IWAKURA, C
    MIYAZAKI, S
    YONEYAMA, H
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 246 (01): : 63 - 72
  • [48] Voltammetric sensor for caffeine based on a glassy carbon electrode modified with Nafion and graphene oxide
    Fangyuan Zhao
    Fei Wang
    Weining Zhao
    Jing Zhou
    Yang Liu
    Lina Zou
    Baoxian Ye
    [J]. Microchimica Acta, 2011, 174 : 383 - 390
  • [49] A Sensitive Chlorpromazine Voltammetric Sensor Based on Graphene Oxide Modified Glassy Carbon Electrode
    Tajik, Somayeh
    Beitollahi, Hadi
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2019, 6 (01): : 171 - 182
  • [50] Voltammetric determination of ascorbic acid with zinc oxide modified glassy carbon electrode
    Nadia Ait Ahmed
    Houa Hammache
    Marielle Eyraud
    Carine Chassigneux
    Florence Vacandio
    Philippe Knauth
    Laid Makhloufi
    Nour-eddine Gabouze
    [J]. Journal of the Iranian Chemical Society, 2019, 16 : 1957 - 1963