IMPRINTING ZEOLITE-MODIFIED GLASSY CARBON AS A VOLTAMMETRIC SENSOR FOR URIC ACID

被引:7
|
作者
Khasanah, Miratul [1 ]
Harsini, Muji [1 ]
Widati, Alfa Akustia [1 ]
机构
[1] Airlangga Univ, Fac Sci & Technol, Dept Chem, Kampus C Unair, Surabaya 60115, Indonesia
关键词
sensor; uric acid; voltammetry; imprinting zeolite; glassy carbon;
D O I
10.22146/ijc.21292
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Development of the uric acid sensor through coating of glassy carbon ( GC) electrode with imprinting zeolite (IZ) was carried out. Zeolite was synthesized by mixing TEOS, TBOT, TPAOH, and water followed by hydrothermal process. Zeolite was molded together with uric acid to produce IZ. The deposition potential of IZ and uric acid to the GC surface was -0.6 V during 150 sec with addition of KNO3 0.02 M as supporting electrolyte. The method gives linearity of 0.9834 (concentration 5.6x10(-9)M - 2.8x10(-8) M), precision 1.89 - 7.65%, sensitivity 0.33 mu A/nM/cm(2), limit of detection 5.9x10(-9) M, and accuracy 96.26 +/- 0.55% (n = 5). The developed sensor showed a high selectivity toward uric acid. The presence of ascorbic acid, creatine, and creatinine with an equal concentration with uric acid did not interfere on the uric acid analysis.
引用
收藏
页码:108 / 113
页数:6
相关论文
共 50 条
  • [21] Zeolite-modified solid carbon paste electrodes
    Alain Walcarius
    Pascal Mariaulle
    Luc Lamberts
    [J]. Journal of Solid State Electrochemistry, 2003, 7 : 671 - 677
  • [22] Differential pulse voltammetric determination of uric acid on carbon-coated iron nanoparticle modified glassy carbon electrodes
    Wang, Shengfu
    Xu, Qiao
    Liu, Guodong
    [J]. ELECTROANALYSIS, 2008, 20 (10) : 1116 - 1120
  • [23] Voltammetric response of the hexammino-ruthenium complex incorporated in zeolite-modified carbon paste electrode
    Walcarius, A
    Lamberts, L
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 422 (1-2) : 77 - 89
  • [24] Zeolite-modified solid carbon paste electrodes
    Walcarius, A
    Mariaulle, P
    Lamberts, L
    [J]. JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2003, 7 (10) : 671 - 677
  • [25] Zinc Oxide Modified Carbon Paste Electrode Sensor for Uric Acid: A Cyclic Voltammetric Study
    Kumar, Mohan
    Swamy, Bahaddurghatta E. Kumara
    Sathisha, Tammanekar V.
    Deepa, Ramachandra
    [J]. ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2015, 7 (05): : 610 - 622
  • [26] Multiwall carbon nanotube modified glassy carbon electrode as voltammetric sensor for the simultaneous determination of ascorbic acid and caffeine
    Gupta, Vinod Kumar
    Jain, Ajay Kumar
    Shoora, Sudhir Kumar
    [J]. ELECTROCHIMICA ACTA, 2013, 93 : 248 - 253
  • [27] Simultaneous Voltammetric Measurement of Ascorbic Acid, Epinephrine, Uric Acid and Tyrosine at a Glassy Carbon Electrode Modified with Nanozeolite-Multiwall Carbon Nanotube
    Noroozifar, M.
    Khorasani-Motlagh, M.
    Akbari, R.
    Parizi, M. Bemanadi
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2014, 1 (01): : 62 - 72
  • [28] Electrodeposition of quercetin at a multi-walled carbon nanotubes modified glassy carbon electrode as a novel and efficient voltammetric sensor for simultaneous determination of levodopa, uric acid and tyramine
    Raoof, Jahan Bakhsh
    Ojani, Reza
    Amiri-Aref, Mohaddeseh
    Baghayeri, Mehdi
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2012, 166 : 508 - 518
  • [29] Screen-printed zeolite-modified carbon electrodes
    Walcarius, A
    Rozanska, S
    Bessière, J
    Wang, J
    [J]. ANALYST, 1999, 124 (08) : 1185 - 1190
  • [30] A poly(3-acetylthiophene) modified glassy carbon electrode for selective voltammetric measurement of uric acid in urine sample
    Aslanoglu, Mehmet
    Kutluay, Aysegul
    Abbasoglu, Sultan
    Karabulut, Serpil
    [J]. CHEMICAL & PHARMACEUTICAL BULLETIN, 2008, 56 (03) : 282 - 286