IMAGING OF THE SKIN WITH 20-MHZ US

被引:155
|
作者
FORNAGE, BD
MCGAVRAN, MH
DUVIC, M
WALDRON, CA
机构
[1] UNIV TEXAS,MD ANDERSON CANCER CTR,DEPT PATHOL,HOUSTON,TX 77030
[2] UNIV TEXAS,MD ANDERSON CANCER CTR,DEPT DERMATOL,HOUSTON,TX 77030
关键词
DERMATITIS; SKIN; DISEASES; NEOPLASMS; US;
D O I
10.1148/radiology.189.1.8372222
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: The authors clinically evaluated a new high-frequency ultrasound (US) scanner to determine the value of US for dermatologic applications. MATERIALS AND METHODS: A 20-MHz US scanner was used to visualize normal skin at eight sites in 10 healthy volunteers and to evaluate 200 skin lesions (45 malignant, 155 benign). RESULTS: In normal skin, the dermis was markedly echogenic and sharply demarcated from hypoechoic subcutaneous fat. The epidermis was not resolved except on the palm and sole. Only three superficial lesions were not identified with US; evaluation of another three was limited by shadowing. Thickness of the lesions visualized was 0.2-26.0 mm (mean, 1.9 mm +/- 2.6). Most lesions (77%) were hypoechoic, 9% were anechoic, 12% had mixed echogenicity, and 2% were isoechoic or hyperechoic. CONCLUSION: The diagnostic role of high-frequency US appears limited. It did not help differentiate benign from malignant lesions, but it did enable accurate delineation of deep margins of lesions and allowed noninvasive measurement of thickness. These features may help in the preoperative evaluation of skin tumors and in monitoring the response to therapy for certain inflammatory conditions.
引用
收藏
页码:69 / 76
页数:8
相关论文
共 50 条
  • [41] Nail thickness measurements using optical coherence tomography and 20-MHz ultrasonography
    Mogensen, M.
    Thomsen, J. B.
    Skovgaard, L. T.
    Jemec, G. B. E.
    BRITISH JOURNAL OF DERMATOLOGY, 2007, 157 (05) : 894 - 900
  • [42] Preoperative melanoma thickness determination by 20-MHz sonography and digital videomicroscopy in combination
    Pellacani, G
    Seidenari, S
    ARCHIVES OF DERMATOLOGY, 2003, 139 (03) : 293 - 298
  • [43] Improved detection of vitreous inhomogeneities using a 20-MHz, ultrasound annular array
    Ketterling, Jeffrey A.
    Gross, Daniel
    Mamou, Jonathan
    Hoang, Quan V.
    Silverman, Ronald H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [44] Evaluation of 20-MHz high-frequency ultrasonography for the diagnosis of choroidal nevi
    Magali Albrieux
    Pierre Pégourié
    Florent Aptel
    Dominique Satger
    Marc Bru
    Georges Zaatar
    Christophe Chiquet
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2021, 259 : 181 - 189
  • [45] Scanning Head with 128-Element 20-MHz PVDF Linear Array Transducer
    Carey, Stephen J.
    Brox-Nilsen, Christian
    Lewis, Hugh M.
    Gregory, Christopher M.
    Hatfield, John V.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (08) : 1769 - 1777
  • [46] EFFECTS OF 20-MHZ RADIOFREQUENCY RADIATION ON RAT HEMATOLOGY, SPLENIC FUNCTION, AND SERUM CHEMISTRY
    WONG, LS
    MERRITT, JH
    KIEL, JL
    RADIATION RESEARCH, 1985, 103 (02) : 186 - 195
  • [47] 20-MHZ ACOUSTIC-WAVES FROM PULSED THERMOELASTIC EXPANSIONS OF CONSTRAINED SURFACES
    GUTFELD, RJV
    MELCHER, RL
    APPLIED PHYSICS LETTERS, 1977, 30 (06) : 257 - 259
  • [48] 20-MHZ B-MODE ULTRASOUND IN MONITORING THE COURSE OF LOCALIZED SCLERODERMA (MORPHEA)
    HOFFMANN, K
    GERBAULET, U
    ELGAMMAL, S
    ALTMEYER, P
    ACTA DERMATO-VENEREOLOGICA, 1991, : 3 - 16
  • [49] Fabrication and Characterization of a 20-MHz Microlinear Phased-Array Transducer for Intervention Guidance
    Chiu, Chi Tat
    Kang, Bong Jin
    Eliahoo, Payam
    Abraham, Theodore
    Shung, K. Kirk
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (08) : 1261 - 1268
  • [50] A-D CONVERTER WITH 10 BITS-SAMPLE BY 20-MHZ SAMPLING RATE
    NINOMIYA, Y
    IEEE TRANSACTIONS ON COMMUNICATIONS, 1980, 28 (01) : 1 - 6