IMAGING OF THE SKIN WITH 20-MHZ US

被引:155
|
作者
FORNAGE, BD
MCGAVRAN, MH
DUVIC, M
WALDRON, CA
机构
[1] UNIV TEXAS,MD ANDERSON CANCER CTR,DEPT PATHOL,HOUSTON,TX 77030
[2] UNIV TEXAS,MD ANDERSON CANCER CTR,DEPT DERMATOL,HOUSTON,TX 77030
关键词
DERMATITIS; SKIN; DISEASES; NEOPLASMS; US;
D O I
10.1148/radiology.189.1.8372222
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: The authors clinically evaluated a new high-frequency ultrasound (US) scanner to determine the value of US for dermatologic applications. MATERIALS AND METHODS: A 20-MHz US scanner was used to visualize normal skin at eight sites in 10 healthy volunteers and to evaluate 200 skin lesions (45 malignant, 155 benign). RESULTS: In normal skin, the dermis was markedly echogenic and sharply demarcated from hypoechoic subcutaneous fat. The epidermis was not resolved except on the palm and sole. Only three superficial lesions were not identified with US; evaluation of another three was limited by shadowing. Thickness of the lesions visualized was 0.2-26.0 mm (mean, 1.9 mm +/- 2.6). Most lesions (77%) were hypoechoic, 9% were anechoic, 12% had mixed echogenicity, and 2% were isoechoic or hyperechoic. CONCLUSION: The diagnostic role of high-frequency US appears limited. It did not help differentiate benign from malignant lesions, but it did enable accurate delineation of deep margins of lesions and allowed noninvasive measurement of thickness. These features may help in the preoperative evaluation of skin tumors and in monitoring the response to therapy for certain inflammatory conditions.
引用
收藏
页码:69 / 76
页数:8
相关论文
共 50 条
  • [31] 68030 EVALUATION BOARD ZIPS THROUGH SOFTWARE AT A FAST 20-MHZ
    PHILLIPS, BW
    ELECTRONIC DESIGN, 1987, 35 (27) : 51 - 52
  • [32] Broadband pump-probe spectroscopy at 20-MHz modulation frequency
    Preda, Fabrizio
    Kumar, Vikas
    Crisafi, Francesco
    del Valle, Diana Gisell Figueroa
    Cerullo, Giulio
    Polli, Dario
    OPTICS LETTERS, 2016, 41 (13) : 2970 - 2973
  • [33] In vivo normal human dermis characterization by 20-MHz ultrasound backscatter
    Fournier, C
    Bridal, SL
    Berger, G
    Laugier, P
    2000 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2000, : 1303 - 1306
  • [34] A High Sensitivity 20-MHz Endoscopic Transducer With Integrated Miniature Amplifier
    Han, Zhile
    Xu, Jie
    Yang, Chen
    Wang, Ninghao
    Li, Zhangjian
    Cui, Yaoyao
    Jian, Xiaohua
    IEEE ACCESS, 2020, 8 : 109241 - 109248
  • [35] MALIGNANT-MELANOMA IN 20-MHZ B-SCAN SONOGRAPHY
    HOFFMANN, K
    JUNG, J
    ELGAMMAL, S
    ALTMEYER, P
    DERMATOLOGY, 1992, 185 (01) : 49 - 55
  • [36] A Digitally Modulated Polar CMOS Power Amplifier With a 20-MHz Channel Bandwidth
    Kavousian, Amirpouya
    Su, David K.
    Hekmat, Mohammad
    Shirvani, Alireza
    Wooley, Bruce A.
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2008, 43 (10) : 2251 - 2258
  • [37] LIGHTNING AMPLITUDE SPECTRA IN THE INTERVAL FROM 100-KHZ TO 20-MHZ
    WEIDMAN, CD
    KRIDER, EP
    UMAN, MA
    GEOPHYSICAL RESEARCH LETTERS, 1981, 8 (08) : 931 - 934
  • [38] Evaluation of 20-MHz high-frequency ultrasonography for the diagnosis of choroidal nevi
    Albrieux, Magali
    Pegourie, Pierre
    Aptel, Florent
    Satger, Dominique
    Bru, Marc
    Zaatar, Georges
    Chiquet, Christophe
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 259 (01) : 181 - 189
  • [39] Evaluation of Posterior Lens Capsule by 20-MHz Ultrasound Probe in Traumatic Cataract
    Tabatabaei, Au
    Kiarudi, Mohammad Yaser
    Ghassemi, Fariba
    Moghimi, Sasan
    Mansouri, Mohammadreza
    Mirshahi, Ahmad
    Kheirkhah, Ahmad
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 153 (01) : 51 - 54