RADON PROGENY REDUCTION BY MEANS OF AN AIR CLEANER OF THE POLARIZED MEDIA TYPE

被引:2
|
作者
BIGU, J
机构
[1] Elliot Lake Laboratory, CANMET, Energy, Mines and Resources Canada, Elliot Lake
来源
ANNALS OF OCCUPATIONAL HYGIENE | 1993年 / 37卷 / 05期
关键词
D O I
10.1093/annhyg/37.5.481
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The performance of an 'air-cleaner' for the control of radon (Rn-222) progeny in dwellings and in laboratory spaces has been investigated in a walk-in Radon/Thoron Test Facility (RTTF). The air cleaner consists of a fan and a special filter material sandwiched between two metal screens to which an electric field is applied. The filter is the polarized fibre-glass media type. The fan and filter system are housed in a metal case. Air is drawn from the back of the case by means of the fan and passed through the 'electrical' filter where removal of Rn-222 progeny occurs. Radon-222 progeny 'depleted' air is discharged at the top of the device. Experiments were carried out in Rn-222/Rn-222 progeny atmospheres when the air cleaner was operating and when it was turned off. A very significant decrease in the Potential Alpha Energy Concentration (PAEC) and aerosol concentration, among other effects, were observed during the operation of the air cleaner. The device has potential in industrial applications, which should be explored.
引用
收藏
页码:481 / 495
页数:15
相关论文
共 50 条
  • [1] THORON (RN-220) PROGENY REDUCTION BY AN AIR CLEANER OF THE POLARIZED MEDIA FILTER TYPE
    BIGU, J
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 325 (1-2): : 357 - 364
  • [2] Radon mitigation using an air cleaner
    Y. Yasuoka
    T. Ishikawa
    S. Tokonami
    H. Takahashi
    A. Sorimachi
    M. Shinogi
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2009, 279 : 885 - 891
  • [3] Radon mitigation using an air cleaner
    Yasuoka, Y.
    Ishikawa, T.
    Tokonami, S.
    Takahashi, H.
    Sorimachi, A.
    Shinogi, M.
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2009, 279 (03) : 885 - 891
  • [4] MEASUREMENT OF RADON PROGENY CONCENTRATIONS IN AIR
    KERR, GD
    [J]. TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1973, 17 (NOV): : 542 - 543
  • [5] INTEGRATING RADON PROGENY AIR SAMPLER
    SCHIAGER, KJ
    [J]. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1974, 35 (03): : 165 - 174
  • [6] EVALUATION OF ROOM AIR CLEANERS FOR THE REDUCTION OF EXPOSURE AND DOSE TO INDOOR RADON PROGENY
    HOPKE, PK
    JENSEN, B
    MONTASSIER, N
    WASIOLEK, P
    [J]. RADIATION PROTECTION DOSIMETRY, 1994, 56 (1-4) : 55 - 60
  • [7] Studies of radon and radon progeny in air conditioned rooms in hospitals
    Marley, F
    Denman, AR
    Phillips, PS
    [J]. RADIATION PROTECTION DOSIMETRY, 1998, 76 (04) : 273 - 276
  • [8] THE CONTROL OF RADON PROGENY BY AIR TREATMENT DEVICES
    RAJALA, M
    JANKA, K
    LEHTIMAKI, M
    KULMALA, V
    GRAEFFE, G
    KESKINEN, J
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 1985, 45 (OCT) : 493 - 498
  • [9] Radon exhalation and ultrafine fraction of radon progeny in closed room air
    El-Hussein, A
    Mohammed, A
    Ahmed, AA
    [J]. ATMOSPHERIC ENVIRONMENT, 1999, 33 (02) : 183 - 190
  • [10] Mitigation effects of radon decay products by air cleaner
    Iwaoka, Kazuki
    Tokonami, Shinji
    Ishikawa, Tetsuo
    Yonehara, Hidenori
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 295 (01) : 639 - 642