RADON PROGENY REDUCTION BY MEANS OF AN AIR CLEANER OF THE POLARIZED MEDIA TYPE

被引:2
|
作者
BIGU, J
机构
[1] Elliot Lake Laboratory, CANMET, Energy, Mines and Resources Canada, Elliot Lake
来源
ANNALS OF OCCUPATIONAL HYGIENE | 1993年 / 37卷 / 05期
关键词
D O I
10.1093/annhyg/37.5.481
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The performance of an 'air-cleaner' for the control of radon (Rn-222) progeny in dwellings and in laboratory spaces has been investigated in a walk-in Radon/Thoron Test Facility (RTTF). The air cleaner consists of a fan and a special filter material sandwiched between two metal screens to which an electric field is applied. The filter is the polarized fibre-glass media type. The fan and filter system are housed in a metal case. Air is drawn from the back of the case by means of the fan and passed through the 'electrical' filter where removal of Rn-222 progeny occurs. Radon-222 progeny 'depleted' air is discharged at the top of the device. Experiments were carried out in Rn-222/Rn-222 progeny atmospheres when the air cleaner was operating and when it was turned off. A very significant decrease in the Potential Alpha Energy Concentration (PAEC) and aerosol concentration, among other effects, were observed during the operation of the air cleaner. The device has potential in industrial applications, which should be explored.
引用
收藏
页码:481 / 495
页数:15
相关论文
共 50 条
  • [41] Radon and thoron progeny levels in air samples at Udagamandalam region of Nilgiris in India
    N. M. Manikandan
    S. Selvasekarapandian
    R. Sivakumar
    V.M. Raghunath
    V.M. Sundaram
    S. Santhanam
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2002, 252 : 249 - 254
  • [42] Influence of aerosol concentration and multivariate processing on the indication of radon progeny concentration in air
    Machaj, B
    Urbanski, P
    [J]. NUKLEONIKA, 2004, 49 (03) : 123 - 129
  • [43] Invariants of the Jacobi-Porstendrfer room model for radon progeny in indoor air
    Thomas, Josef
    Jilek, Karel
    [J]. RADIATION PROTECTION DOSIMETRY, 2012, 150 (02) : 142 - 149
  • [44] Activity size distributions of short-lived radon progeny in indoor air
    Mohammed, A
    [J]. RADIATION PROTECTION DOSIMETRY, 1999, 86 (02) : 139 - 145
  • [45] Radon and thoron progeny levels in air samples at Udagamandalam region of Nilgiris in India
    Manikandan, NM
    Selvasekarapandian, S
    Sivakumar, R
    Raghunath, VM
    Sundaram, VM
    Santhanam, S
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2002, 252 (02) : 249 - 254
  • [46] PROTECTION AGAINST RADON PROGENY INHALATION USING FILTER TYPE RESPIRATORS
    MARTZ, DE
    SCHIAGER, KJ
    [J]. HEALTH PHYSICS, 1969, 17 (02): : 219 - +
  • [47] 2-STAGE CHARGED MEDIA ELECTRONIC AIR CLEANER
    BOSWORTH, CM
    MCIVER, SH
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1972, 14 (09): : 64 - &
  • [48] On the simultaneous indoor measurement of the exhalation rates of radon gas from open soil and the concentration of radon progeny in the surrounding air
    Nishimura, K
    Mochizuki, S
    Tanji, T
    [J]. IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 2, 1996, : B35 - B37
  • [49] Looping variation of correlation between radon progeny concentration and dose rate in outdoor air
    Fujinami, N
    Watanabe, T
    Tsutsui, I
    [J]. Natural Radiation Environment VII, 2005, 7 : 284 - 289
  • [50] Unattached fraction and size distribution of aerosol-attached radon progeny in the open air
    ElHussein, A
    Ahmed, AA
    [J]. APPLIED RADIATION AND ISOTOPES, 1995, 46 (12) : 1393 - 1399