A series of continuous real-time radon and radon progeny measurements together with passive etched track detector measurements were performed in hospital premises during 1996. In one small room: derailed measurements over several weeks showed that both the radon concentration and the Equilibrium Factor depended on the intermittent operation of a filtered positive pressure displacement air-conditioning system, which was designed to conform to operating theatre standards. The average radon level measured while the air-conditioning was off was almost four times higher than that recorded whilst it was on. The progeny level was over five times higher than that whilst it was on. Thus, the Equilibrium Factor (F), was significantly lower when the air-conditioning was on. Measurements in similar rooms in two hospitals, confirmed that the reduction in radon level was a general finding. Thus staff working in such environments receive significantly lower radiation dose from radon than staff working in nearby normally ventilated rooms.
引用
收藏
页码:273 / 276
页数:4
相关论文
共 50 条
  • [1] Study on radon and radon progeny in some living rooms
    Mohamed, A
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 117 (04) : 402 - 407
  • [2] CONCENTRATIONS OF RADON AND ITS PROGENY IN THE ROOMS OF POLISH SPAS
    CHRUSCIELEWSKI, W
    DOMANSKI, T
    ORZECHOWSKI, W
    [J]. HEALTH PHYSICS, 1983, 45 (02): : 421 - 424
  • [3] MEASUREMENT OF RADON PROGENY CONCENTRATIONS IN AIR
    KERR, GD
    [J]. TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1973, 17 (NOV): : 542 - 543
  • [4] INTEGRATING RADON PROGENY AIR SAMPLER
    SCHIAGER, KJ
    [J]. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1974, 35 (03): : 165 - 174
  • [5] MEASUREMENT OF RADON AND RADON PROGENY
    BERNHARDT, DE
    [J]. HEALTH PHYSICS, 1983, 45 (01): : 246 - 246
  • [6] RADON AND RADON PROGENY MEASUREMENTS
    HOPKE, PK
    WASIOLEK, P
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1991, 10 (08) : 243 - 249
  • [7] Radon exhalation and ultrafine fraction of radon progeny in closed room air
    El-Hussein, A
    Mohammed, A
    Ahmed, AA
    [J]. ATMOSPHERIC ENVIRONMENT, 1999, 33 (02) : 183 - 190
  • [8] Characteristics of radon and its progeny concentrations in air-conditioned office buildings in Tokyo
    Tokonami, S
    Furukawa, M
    Shicchi, Y
    Sanada, T
    Yamada, Y
    [J]. RADIATION PROTECTION DOSIMETRY, 2003, 106 (01) : 71 - 76
  • [9] A study on radon and radon progeny in surface air of El-Minia, Egypt
    El-Hussein, A
    Mohammed, A
    Ahmed, AA
    [J]. RADIATION PROTECTION DOSIMETRY, 1998, 78 (02) : 139 - 145
  • [10] Radon and radon progeny in the Carlsbad Caverns
    Cheng, YS
    Chen, TR
    Wasiolek, PT
    VanEngen, A
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 1997, 26 (01) : 74 - 92