Studies of radon and radon progeny in air conditioned rooms in hospitals

被引:18
|
作者
Marley, F [1 ]
Denman, AR
Phillips, PS
机构
[1] Northampton Gen Hosp, Dept Med Phys, Northampton NN1 5BD, England
[2] Nene Coll, Sch Environm Sci, Northampton NN2 7AL, England
关键词
D O I
10.1093/oxfordjournals.rpd.a032274
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A series of continuous real-time radon and radon progeny measurements together with passive etched track detector measurements were performed in hospital premises during 1996. In one small room: derailed measurements over several weeks showed that both the radon concentration and the Equilibrium Factor depended on the intermittent operation of a filtered positive pressure displacement air-conditioning system, which was designed to conform to operating theatre standards. The average radon level measured while the air-conditioning was off was almost four times higher than that recorded whilst it was on. The progeny level was over five times higher than that whilst it was on. Thus, the Equilibrium Factor (F), was significantly lower when the air-conditioning was on. Measurements in similar rooms in two hospitals, confirmed that the reduction in radon level was a general finding. Thus staff working in such environments receive significantly lower radiation dose from radon than staff working in nearby normally ventilated rooms.
引用
收藏
页码:273 / 276
页数:4
相关论文
共 50 条
  • [21] Investigation of the air pressure characteristics influencing the variability of radon gas and radon progeny in domestic vernacular buildings
    Marley, F
    [J]. HEALTH PHYSICS, 2001, 81 (01): : 57 - 69
  • [22] Effectiveness of airborne radon progeny assessment for atmospheric studies
    Crova, F.
    Valli, G.
    Bernardoni, V
    Forello, A. C.
    Valentini, S.
    Vecchi, R.
    [J]. ATMOSPHERIC RESEARCH, 2021, 250
  • [23] Dosimetry of radon progeny deposited on skin in air and thermal water
    Sakoda, Akihiro
    Ishimori, Yuu
    Kanzaki, Norie
    Tanaka, Hiroshi
    Kataoka, Takahiro
    Mitsunobu, Fumihiro
    Yamaoka, Kiyonori
    [J]. JOURNAL OF RADIATION RESEARCH, 2021, 62 (04) : 634 - 644
  • [24] EVALUATION OF SEVERAL AIR CLEANERS FOR REDUCING INDOOR RADON PROGENY
    HOPKE, PK
    JENSEN, B
    MONTASSIER, N
    [J]. JOURNAL OF AEROSOL SCIENCE, 1994, 25 (02) : 395 - 405
  • [25] EXTERNAL GAMMA-EXPOSURE TO RADON PROGENY IN INDOOR AIR
    FUJIMOTO, K
    [J]. JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1985, 22 (12) : 1001 - 1010
  • [26] Continuous measurements of radon and radon progeny as a basis for management of radon as a hazard in a tourist cave
    W. Zahorowski
    S. Whittlestone
    J. M. James
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 1998, 236 : 219 - 225
  • [27] Corrections to Kusnetz method for measurements of radon progeny concentrations in air
    Nusair, O.
    [J]. JOURNAL OF INSTRUMENTATION, 2021, 16 (12)
  • [28] Hourly measurement method for radon progeny volumetric activity in air
    Jasaitis, Dainius
    Girgzdys, Aloyzas
    [J]. JOURNAL OF ENVIRONMENTAL ENGINEERING AND LANDSCAPE MANAGEMENT, 2007, 15 (03) : 158 - 165
  • [29] Analysis of radon and thoron progeny measurements based on air filtration
    Stajic, J. M.
    Nikezic, D.
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 163 (03) : 333 - 340
  • [30] Size distribution of radon progeny aerosols in indoor and outdoor air
    Shimo, M
    Saito, H
    [J]. JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2000, 51 (01) : 49 - 57