POSITRON EMISSION TOMOGRAPHIC MEASUREMENT OF CEREBRAL BLOOD-FLOW AND TEMPORAL LOBECTOMY

被引:42
|
作者
THEODORE, WH
GAILLARD, WD
SATO, S
KUFTA, C
LEIDERMAN, D
机构
[1] NINCDS,EPILEPSY RES BRANCH,BETHESDA,MD
[2] NINCDS,SURG NEUROL BRANCH,BETHESDA,MD
关键词
D O I
10.1002/ana.410360220
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We used positron emission tomography (PET) and bolus injection of (H2O)-O-15 to measure interictal cerebral blood flow (CBF) in 32 patients who had temporal lobectomy for uncontrolled complex partial seizures. Seizure focus localization was confirmed by ictal video-electroencephalographic (video-EEG) telemetry, and patients who had imaging findings suggesting the presence of a tumor were excluded. PET-CBF studies were interpreted using a standard template by raters blinded to EEG and clinical data, and were not used in surgical planning. After surgery, patients were followed for 32 +/- 18 months. Twenty-six patients were seizure free and 6 had persistent seizures. Mean lateral temporal hypoperfusion was 8 +/- 14% in patients who became seizure free and 9 +/- 6% in patients with persistent seizures. Fourteen patients had at least 15%, and 11 at least 20% hypoperfusion, but were not more likely to be seizure free. Three additional patients had 15 to 20% hypoperfusion in the temporal lobe contralateral to their EEG focus. PET measurement of CBF using bolus (H2O)-O-15 should not be used to help select patients for temporal lobectomy.
引用
收藏
页码:241 / 244
页数:4
相关论文
共 50 条
  • [21] MEASUREMENT OF ABSOLUTE BONE BLOOD-FLOW BY POSITRON EMISSION TOMOGRAPHY
    NAHMIAS, C
    COCKSHOTT, WP
    BELBECK, LW
    GARNETT, ES
    [J]. SKELETAL RADIOLOGY, 1986, 15 (03) : 198 - 200
  • [22] MEASUREMENT OF RENAL BLOOD-FLOW USING POSITRON EMISSION TOMOGRAPHY
    GREEN, JA
    MIRALDI, F
    LEISURE, GP
    NELSON, D
    BERRIDGE, M
    GRINBLATT, M
    [J]. PHARMACOTHERAPY, 1988, 8 (02): : 128 - 128
  • [23] CEREBRAL BLOOD-FLOW VELOCITY AS DETERMINED BY DOPPLER IS RELATED TO REGIONAL CEREBRAL BLOOD-FLOW AS DETERMINED BY POSITRON EMISSION TOMOGRAPHY
    PERLMAN, JM
    HERSCOVITCH, P
    CORRIVEAU, S
    RAICHLE, ME
    VOLPE, JJ
    [J]. ANNALS OF NEUROLOGY, 1985, 18 (03) : 407 - 407
  • [24] COMPUTED TOMOGRAPHIC MEASUREMENT OF LOCAL CEREBRAL BLOOD-FLOW BY XENON ENHANCEMENT
    SEGAWA, H
    WAKAI, S
    TAMURA, A
    YOSHIMASU, N
    NAKAMURA, O
    OHTA, M
    [J]. STROKE, 1983, 14 (03) : 356 - 362
  • [25] THE ASSESSMENT OF REGIONAL CEREBRAL BLOOD-FLOW IN THE NEWBORN WITH POSITRON EMISSION TOMOGRAPHY
    HERSCOVITCH, P
    PERLMAN, JM
    VOLPE, JJ
    RAICHLE, ME
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1983, 24 (05) : P22 - P22
  • [26] IMAGING OF CEREBRAL BLOOD-FLOW AND METABOLISM IN AMBLYOPIA BY POSITRON EMISSION TOMOGRAPHY
    DEMER, JL
    VONNOORDEN, GK
    VOLKOW, ND
    GOULD, KL
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1988, 105 (04) : 337 - 347
  • [27] POSITRON EMISSION TOMOGRAPHY IN THE ASSESSMENT OF REGIONAL CEREBRAL BLOOD-FLOW IN THE NEWBORN
    VOLPE, JJ
    PERLMAN, JM
    HERSCOVITCH, P
    RAICHLE, ME
    [J]. ANNALS OF NEUROLOGY, 1982, 12 (02) : 225 - 226
  • [29] CAFFEINE AND HUMAN CEREBRAL BLOOD-FLOW - A POSITRON EMISSION TOMOGRAPHY STUDY
    CAMERON, OG
    MODELL, JG
    HARIHARAN, M
    [J]. LIFE SCIENCES, 1990, 47 (13) : 1141 - 1146
  • [30] POTENTIALS OF POSITRON EMISSION TOMOGRAPHY FOR REGIONAL CEREBRAL BLOOD-FLOW EVALUATION
    DEPRESSEUX, JC
    [J]. JOURNAL DE BIOPHYSIQUE & MEDECINE NUCLEAIRE, 1982, 6 (04): : 167 - 171