POSITRON EMISSION TOMOGRAPHIC MEASUREMENT OF CEREBRAL BLOOD-FLOW AND TEMPORAL LOBECTOMY

被引:42
|
作者
THEODORE, WH
GAILLARD, WD
SATO, S
KUFTA, C
LEIDERMAN, D
机构
[1] NINCDS,EPILEPSY RES BRANCH,BETHESDA,MD
[2] NINCDS,SURG NEUROL BRANCH,BETHESDA,MD
关键词
D O I
10.1002/ana.410360220
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We used positron emission tomography (PET) and bolus injection of (H2O)-O-15 to measure interictal cerebral blood flow (CBF) in 32 patients who had temporal lobectomy for uncontrolled complex partial seizures. Seizure focus localization was confirmed by ictal video-electroencephalographic (video-EEG) telemetry, and patients who had imaging findings suggesting the presence of a tumor were excluded. PET-CBF studies were interpreted using a standard template by raters blinded to EEG and clinical data, and were not used in surgical planning. After surgery, patients were followed for 32 +/- 18 months. Twenty-six patients were seizure free and 6 had persistent seizures. Mean lateral temporal hypoperfusion was 8 +/- 14% in patients who became seizure free and 9 +/- 6% in patients with persistent seizures. Fourteen patients had at least 15%, and 11 at least 20% hypoperfusion, but were not more likely to be seizure free. Three additional patients had 15 to 20% hypoperfusion in the temporal lobe contralateral to their EEG focus. PET measurement of CBF using bolus (H2O)-O-15 should not be used to help select patients for temporal lobectomy.
引用
收藏
页码:241 / 244
页数:4
相关论文
共 50 条
  • [31] MEASUREMENT OF CEREBRAL BLOOD-FLOW AND VOLUME WITH POSITRON EMISSION TOMOGRAPHY DURING ISOFLURANE ADMINISTRATION IN THE HYPOCAPNIC BABOON
    ARCHER, DP
    LABRECQUE, P
    TYLER, JL
    MEYER, E
    EVANS, AC
    VILLEMURE, JG
    CASEY, WF
    DIKSIC, M
    HAKIM, AM
    TROP, D
    [J]. ANESTHESIOLOGY, 1990, 72 (06) : 1031 - 1037
  • [32] MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW DURING VOLITIONAL BREATHING USING POSITRON EMISSION TOMOGRAPHY IN MAN
    COLEBATCH, JG
    ADAMS, L
    MURPHY, K
    MARTIN, AJ
    LAMMERTSMA, AA
    TOCHONDANGUY, HJ
    CLARK, JC
    FRISTON, KJ
    GUZ, A
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1991, 438 : P24 - P24
  • [34] QUANTITATIVE MEASUREMENT OF REGIONAL PULMONARY BLOOD-FLOW WITH POSITRON EMISSION TOMOGRAPHY
    MINTUN, MA
    TERPOGOSSIAN, MM
    GREEN, MA
    LICH, LL
    SCHUSTER, DP
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1986, 60 (01) : 317 - 326
  • [35] TOMOGRAPHIC CEREBRAL BLOOD-FLOW CALCULATION - REPLY
    STOKELY, EM
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1985, 5 (04): : 618 - 619
  • [36] MEASUREMENT OF CEREBRAL BLOOD-FLOW
    HARPER, AM
    GLASS, HI
    [J]. LANCET, 1963, 1 (729): : 1262 - &
  • [37] MEASUREMENT OF CEREBRAL BLOOD-FLOW
    VEALL, N
    MALLETT, BL
    [J]. LANCET, 1963, 2 (729): : 91 - +
  • [38] POSITRON EMISSION TOMOGRAPHIC MEASUREMENT OF BONE-MARROW BLOOD-FLOW TO THE PELVIS AND LUMBAR VERTEBRAE IN YOUNG NORMAL ADULTS
    KAHN, D
    WEINER, GJ
    BENHAIM, S
    PONTO, LLB
    MADSEN, MT
    BUSHNELL, DL
    WATKINS, GL
    ARGENYI, EA
    HICHWA, RD
    [J]. BLOOD, 1994, 83 (04) : 958 - 963
  • [39] CEREBRAL BLOOD-FLOW RESPONSE TO STROBOSCOPIC LIGHT MEASURED WITH POSITRON EMISSION TOMOGRAPHY
    VOLKOW, ND
    MULLANI, N
    GOULD, L
    BOLOMEY, L
    TEWSON, T
    BERRIDGE, M
    REILLY, E
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1985, 11 (2-3): : A5 - A5
  • [40] REDUCTION IN CEREBRAL BLOOD-FLOW DURING HYPERVENTILATION - AN EVALUATION BY POSITRON EMISSION TOMOGRAPHY
    BEDNARCZYK, EM
    PANACEK, EA
    LEISURE, G
    MUNGER, MA
    GREEN, JA
    MIRALDI, F
    RUTHERFORD, WF
    [J]. PHARMACOTHERAPY, 1988, 8 (02): : 134 - 134