MEASURING PASSIVE CERVICAL MOTION - A STUDY OF RELIABILITY

被引:0
|
作者
NILSSON, N [1 ]
机构
[1] NORDIC INST CHIROPRACT,ODENSE,DENMARK
关键词
CERVICAL VERTEBRAE; MOTION; RELIABILITY; VALIDITY;
D O I
暂无
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Purpose: To study the inter- and intraexaminer reliability of assessing passive cervical range of motion. Design: Blind, repeated measures of passive cervical range of motion by two different examiners. Setting: Ambulatory outpatient facility in an independent NHS funded chiropractic research institution. Participants: Fourteen asymptomatic volunteers, 7 men and 7 women, aged 23-45 years. Intervention: Measurement of passive cervical range of motion using a strap-on head goniometer by two blinded examiners. Each subject was measured three times with 20-min intervals between each measurment, using a mean-of-five-measurements protocol. Main Outcome Measure: Passive cervical range of motion in 6 separate directions of movement from ''neutral zero''-right and left lateral flexion, right and left rotation and flexion and extension. Results: The inter- and intraexaminer reliability was evaluated using a paired t test and Pearson's Correlation Coefficient (supplemented by a scatterplot). Intraexaminer reliability was found to be acceptable (Pearson's r = 0.61-0.86), whereas interexaminer reliability was less than acceptable (Pearson's r = 0.29-0.66). Conclusion: Passive cervical range of motion could be measured reliably on different occasions by the same examiner but not by different examiners. It is unclear whether low interexaminer reliability in the present study was because of inherent methodological problems or because of insufficient training of examiners before the study.
引用
收藏
页码:293 / 297
页数:5
相关论文
共 50 条
  • [21] Reproducibility of the measurement of active and passive cervical range of motion
    Hoppenbrouwers, Mirrin
    Eckhardt, Martine M. E. M.
    Verkerk, Karin
    Verhagen, Arianne
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2006, 29 (05) : 363 - 367
  • [22] Reliability of measuring half-cycle cervical range of motion may be increased using a spirit level for calibration
    Wilke, Jan
    Niederer, Daniel
    Vogt, Lutz
    Banzer, Winfried
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2018, 33 : 99 - 104
  • [23] Concurrent validity and reliability of measuring range of motion during the cervical flexion rotation test with a novel digital goniometer
    Kerstin Luedtke
    Thomas Schoettker-Königer
    Toby Hall
    Christine Reimer
    Maike Grassold
    Petra Hasselhoff-Styhler
    Christian Neulinger
    Max Obrocki
    Philipp Przyhoda
    Axel Schäfer
    BMC Musculoskeletal Disorders, 21
  • [24] Concurrent validity and reliability of measuring range of motion during the cervical flexion rotation test with a novel digital goniometer
    Luedtke, Kerstin
    Schoettker-Koeniger, Thomas
    Hall, Toby
    Enns, Christine
    Grassold, Maike
    Hasselhoff-Styhler, Petra
    Neulinger, Christian
    Obrocki, Max
    Przyhoda, Philipp
    Schaefer, Axel
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [25] MyotonPRO as a new valid tool for measuring cervical muscle tension. A reliability study
    de la Cierva, Sol Ferran
    Terrasa, David
    Garaycochea, Octavio
    del Rio, Beatriz
    Urdin, Mikel
    Fernandez, Secundino
    LOGOPEDICS PHONIATRICS VOCOLOGY, 2024,
  • [26] Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients
    Nussbaumer, Silvio
    Leunig, Michael
    Glatthorn, Julia F.
    Stauffacher, Simone
    Gerber, Hans
    Maffiuletti, Nicola A.
    BMC MUSCULOSKELETAL DISORDERS, 2010, 11
  • [27] Cervical Range of Motion Analysis Performed with an Accelerometer: A Study of Intersession Reliability for Dental Practice
    Nota, Alessandro
    Pittari, Laura
    Gamba, Laura
    Monticciolo, Francesco Manfredi
    Lannes, Alessia
    Carta, Carlotta
    Beraldi, Alessandro
    Baldini, Alberto
    Marzo, Giuseppe
    Tecco, Simona
    HEALTHCARE, 2023, 11 (10)
  • [28] Comparison of Methods of Measuring Active Cervical Range of Motion
    Whitcroft, Katherine L.
    Massouh, Laura
    Amirfeyz, Rouin
    Bannister, Gordon
    SPINE, 2010, 35 (19) : E976 - E980
  • [29] RELIABILITY AND USE OF THE INCLINOMETER FOR CERVICAL RANGE OF MOTION MEASUREMENTS
    BARBEE, JA
    SANDSTEDT, AE
    PANICHELLA, JL
    CRANDELL, CE
    PHYSICAL THERAPY, 1988, 68 (05): : 826 - 827
  • [30] INTRATESTER AND INTERTESTER RELIABILITY OF THE CERVICAL RANGE OF MOTION DEVICE
    CAPUANOPUCCI, D
    RHEAULT, W
    AUKAI, J
    BRACKE, M
    DAY, R
    PASTRICK, M
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1991, 72 (05): : 338 - 340