MEASURING PASSIVE CERVICAL MOTION - A STUDY OF RELIABILITY

被引:0
|
作者
NILSSON, N [1 ]
机构
[1] NORDIC INST CHIROPRACT,ODENSE,DENMARK
关键词
CERVICAL VERTEBRAE; MOTION; RELIABILITY; VALIDITY;
D O I
暂无
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Purpose: To study the inter- and intraexaminer reliability of assessing passive cervical range of motion. Design: Blind, repeated measures of passive cervical range of motion by two different examiners. Setting: Ambulatory outpatient facility in an independent NHS funded chiropractic research institution. Participants: Fourteen asymptomatic volunteers, 7 men and 7 women, aged 23-45 years. Intervention: Measurement of passive cervical range of motion using a strap-on head goniometer by two blinded examiners. Each subject was measured three times with 20-min intervals between each measurment, using a mean-of-five-measurements protocol. Main Outcome Measure: Passive cervical range of motion in 6 separate directions of movement from ''neutral zero''-right and left lateral flexion, right and left rotation and flexion and extension. Results: The inter- and intraexaminer reliability was evaluated using a paired t test and Pearson's Correlation Coefficient (supplemented by a scatterplot). Intraexaminer reliability was found to be acceptable (Pearson's r = 0.61-0.86), whereas interexaminer reliability was less than acceptable (Pearson's r = 0.29-0.66). Conclusion: Passive cervical range of motion could be measured reliably on different occasions by the same examiner but not by different examiners. It is unclear whether low interexaminer reliability in the present study was because of inherent methodological problems or because of insufficient training of examiners before the study.
引用
收藏
页码:293 / 297
页数:5
相关论文
共 50 条
  • [41] Reliability and Validity of Cervical Range of Motion and Muscle Strength Testing
    Kubas, Christian
    Chen, Yi-Wen
    Echeverri, Silvana
    McCann, Stephanie L.
    Denhoed, Marcia J.
    Walker, Catherine J.
    Kennedy, Carol N.
    Reid, W. Darlene
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2017, 31 (04) : 1087 - 1096
  • [42] Development and testing of a new application for measuring motion at the cervical spine
    Koji Fujita
    Kana Matsuo
    Takafumi Koyama
    Kurando Utagawa
    Shingo Morishita
    Yuta Sugiura
    BMC Medical Imaging, 22
  • [43] Development and testing of a new application for measuring motion at the cervical spine
    Fujita, Koji
    Matsuo, Kana
    Koyama, Takafumi
    Utagawa, Kurando
    Morishita, Shingo
    Sugiura, Yuta
    BMC MEDICAL IMAGING, 2022, 22 (01)
  • [44] Passive range of motion in patients with adhesive shoulder capsulitis, an intertester reliability study over eight weeks
    Sharma, Satya Pal
    Baerheim, Anders
    Kvale, Alice
    BMC MUSCULOSKELETAL DISORDERS, 2015, 16
  • [45] Reliability and Precision of Measuring Humeral Rotation Range of Motion with a Goniometer
    Wassinger, Craig A.
    Myers, Joseph B.
    Oyama, Saki
    Ricci, Robert D.
    Jolly, John T.
    Lephart, Scott M.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2006, 38 (05): : S13 - S13
  • [46] Passive range of motion in patients with adhesive shoulder capsulitis, an intertester reliability study over eight weeks
    Satya Pal Sharma
    Anders Bærheim
    Alice Kvåle
    BMC Musculoskeletal Disorders, 16
  • [47] MEASURING PATIENT INTENSITY - A RELIABILITY STUDY
    PRESCOTT, PA
    SOEKEN, KL
    RYAN, JW
    EVALUATION & THE HEALTH PROFESSIONS, 1989, 12 (03) : 255 - 269
  • [48] MEASURING SEVERITY OF ILLNESS - A RELIABILITY STUDY
    HORN, SD
    CHACHICH, B
    CLOPTON, C
    MEDICAL CARE, 1983, 21 (07) : 705 - 714
  • [49] MEASURING FEAR OF DEATH - RELIABILITY STUDY
    LARRABEE, MJ
    JOURNAL OF PSYCHOLOGY, 1978, 100 (01): : 33 - 37
  • [50] Between-week reliability of the cervical range of motion (CROM) device for upper cervical rotation
    Gugliotti, Mark
    Tau, Jessica
    Gallo, Kelly
    Sagliocca, Natalina
    Horan, Michael
    Sussman, Nicole
    Wisnewski, Robert
    JOURNAL OF MANUAL & MANIPULATIVE THERAPY, 2021, 29 (03) : 176 - 180