Performance of co-current and counter-current parallel flow three-fluid heat exchanger due to perturbations in flow

被引:0
|
作者
Singh, Sanjay Kumar [1 ]
Mishra, Manish [1 ]
Jha, P. K. [1 ]
机构
[1] Indian Inst Technol Roorkee, Dept Mech & Ind Engn, Roorkee 247667, Uttarakhand, India
关键词
finite difference; flow perturbation; parallel flow; three-fluid heat exchangers; transient behaviour;
D O I
10.1504/IJGEI.2016.076342
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Transient behaviour of co-current and countercurrent parallel flow three-fluid heat exchanger with all the three fluids unmixed, has been numerically investigated for perturbations provided in flow. Results are presented for step change in flow rate of all the three fluids. It has been found that the mean exit temperature is greatly affected due to variation in the flow rate and thereby affecting the rate of heat transfer among the three fluids.
引用
收藏
页码:144 / 156
页数:13
相关论文
共 50 条
  • [31] A novel method for combined entropy generation and economic optimization of counter-current and co-current heat exchangers
    Genic, Srbislav
    Jacimovic, Branislav
    Petrovic, Andrija
    APPLIED THERMAL ENGINEERING, 2018, 136 : 327 - 334
  • [32] An analytical method for determining transient temperature field in a parallel-flow three-fluid heat exchanger
    Bielski, S
    Malinowski, L
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2005, 32 (08) : 1034 - 1044
  • [34] Co-current and counter-current modes for water gas shift membrane reactor
    Basile, A
    Paturzo, L
    Gallucci, F
    CATALYSIS TODAY, 2003, 82 (1-4) : 275 - 281
  • [35] Co-current and counter-current modes for methanol steam reforming membrane reactor
    Gallucci, Fausto
    Basile, Angelo
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2006, 31 (15) : 2243 - 2249
  • [36] Limit Solutions for a Lumped Parameter Model of Heat Transfer in a Diluted and Indirectly Heated Co-Current/Counter-Current Moving Bed Heat Exchanger with Heat Loss to Surroundings
    Bertoli, Savio L.
    de Souza, Carolina K.
    Goncalves, Marcel Jefferson
    Padoin, Natan
    Soares, Cintia
    APPLIED THERMAL ENGINEERING, 2024, 236
  • [37] Analysis on a Counter-Current Flow Hemodialyzer
    Loney, Norman W.
    CHEMICAL PRODUCT AND PROCESS MODELING, 2009, 4 (05):
  • [38] Hydrogen removal from aluminium in co-current and counter-current bubble columns
    Syvertsen, M
    Frisvold, F
    Engh, TA
    Voss, DS
    LIGHT METALS 1999, 1999, : 663 - 670
  • [39] A Comparison of Co-current and Counter-current Modes of Operation in Urea Prilling Tower
    Rahamnian, Nejat
    Homayoonfard, Marjan
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON PROCESS ENGINEERING AND ADVANCED MATERIALS 2012-ICPEAM 2012, 2014, 917 : 199 - 208
  • [40] Modeling of co-current and counter-current bubble columns with an extended EMMS approach
    Guan, Xiaoping
    Yang, Ning
    PARTICUOLOGY, 2019, 44 : 126 - 135