Performance of co-current and counter-current parallel flow three-fluid heat exchanger due to perturbations in flow

被引:0
|
作者
Singh, Sanjay Kumar [1 ]
Mishra, Manish [1 ]
Jha, P. K. [1 ]
机构
[1] Indian Inst Technol Roorkee, Dept Mech & Ind Engn, Roorkee 247667, Uttarakhand, India
关键词
finite difference; flow perturbation; parallel flow; three-fluid heat exchangers; transient behaviour;
D O I
10.1504/IJGEI.2016.076342
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Transient behaviour of co-current and countercurrent parallel flow three-fluid heat exchanger with all the three fluids unmixed, has been numerically investigated for perturbations provided in flow. Results are presented for step change in flow rate of all the three fluids. It has been found that the mean exit temperature is greatly affected due to variation in the flow rate and thereby affecting the rate of heat transfer among the three fluids.
引用
收藏
页码:144 / 156
页数:13
相关论文
共 50 条
  • [21] Semiglobal Exponential Stability of a Counter-Current and Co-Current Guidance Scheme
    Caharija, Walter
    Grotli, Esten I.
    Pettersen, Kristin Y.
    IFAC PAPERSONLINE, 2018, 51 (29): : 274 - 280
  • [22] Co-current and counter-current spraying of odour-neutralizing products
    Bouzin-Turpin, Aurelie
    Couvert, Annabelle
    Laplanche, Alain
    Paillier, Anne
    ENVIRONMENTAL TECHNOLOGY, 2009, 30 (14) : 1511 - 1517
  • [23] Co-current and counter-current fixed bed combustion of biofuel - a comparison
    Thunman, H
    Leckner, B
    FUEL, 2003, 82 (03) : 275 - 283
  • [24] Wall effects on the velocities of a single sphere settling in a stagnant and counter-current fluid and rising in a co-current fluid
    Arsenijevic, Z. Lj
    Grbavcic, Z. B.
    Garic-Grulovic, R. V.
    Bakovic-Vragolovic, N. M.
    POWDER TECHNOLOGY, 2010, 203 (02) : 237 - 242
  • [25] On the conditional superiority of counter-current over co-current extraction in microchannels
    Picardo, J. R.
    Pushpavanam, S.
    MICROFLUIDICS AND NANOFLUIDICS, 2013, 15 (05) : 701 - 713
  • [26] Direct-contact condensation of pure steam on co-current and counter-current stratified liquid flow in a circular pipe
    Park, Hyun-Sik
    Choi, Sung-Won
    No, Hee Cheon
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (5-6) : 1112 - 1122
  • [27] Thermal effectiveness of heat exchanger with counter-current cross-flow configuration and alternate flow direction in tubes
    Bes, T
    HEAT TRANSFER 1998, VOL 6: GENERAL PAPERS, 1998, : 261 - 266
  • [28] Evaluation of dual flow counter-current chromatography and intermittent counter-current extraction
    Ignatova, Svetlana
    Hewitson, Peter
    Mathews, Ben
    Sutherland, Ian
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (36) : 6102 - 6106
  • [29] Effect of ambient heat-in-leak on the performance of three-fluid cross-flow heat exchanger
    Jyothiprakash, K. H.
    Krishnegowda, Y. T.
    Venkataram, Krishna
    Seetharamu, K. N.
    INTERNATIONAL JOURNAL OF NUMERICAL METHODS FOR HEAT & FLUID FLOW, 2018, 28 (09) : 2012 - 2035
  • [30] Entropy generation analysis of parallel and counter-flow three-fluid heat exchangers with three thermal communications
    Ruan Deng-Fang
    Yuan Xiao-Feng
    Li, You-Rong
    Wu, Shuang-Ying
    JOURNAL OF NON-EQUILIBRIUM THERMODYNAMICS, 2011, 36 (02) : 141 - 154