A Si(Li)-detector has been calibrated for low and medium X-ray energies (E-nu less than or similar to 10 keV) using the method of variation of the X-ray incidence angle, of which the theory is briefly outlined. If the thickness of the Au-contact layer is assumed to be known, the thicknesses of the Si-dead layer and of the Be-window have been determined from a least-squares fit to the experimental data, which were obtained at different X-ray energies. A mathematical simulation of the Bremsstrahlung spectrum, recorded by the detector, confirmed that the obtained results can be regarded as realistic and reliable.
引用
收藏
页码:147 / 152
页数:6
相关论文
共 50 条
  • [1] An in-situ movable calibration source for cryogenic particle detectors
    Mast, N.
    Fritts, M.
    Sincavage, D. J.
    Cushman, P.
    Mandic, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 971
  • [2] Virtual in-situ calibration method in building systems
    Yu, Yuebin
    Li, Haorong
    AUTOMATION IN CONSTRUCTION, 2015, 59 : 59 - 67
  • [3] Development of an in-situ calibration device of firn properties for Askaryan neutrino detectors
    Beise, Jakob
    Glaser, Christian
    37TH INTERNATIONAL COSMIC RAY CONFERENCE, ICRC2021, 2022,
  • [4] Performance standard on the calibration of germanium detectors for in-situ gamma ray measurements.
    Shebell, P
    HEALTH PHYSICS, 2002, 82 (06): : S194 - S195
  • [5] THE IN-SITU CALIBRATION METHOD FOR AMBIENT DOSE EQUIVALENT DOSEMETERS
    Gao, Fei
    Wang, Feifei
    Xu, Yang
    Zhang, Xinyu
    RADIATION PROTECTION DOSIMETRY, 2021, 196 (1-2) : 85 - 94
  • [6] IN-SITU VACUUM GAUGE CALIBRATION BY REFERENCE TRANSFER METHOD
    BLADO, LD
    LILIENKA.RH
    JOURNAL OF ENVIRONMENTAL SCIENCES, 1972, 15 (01): : 24 - &
  • [7] A Technique for In-Situ Calibration of Semiconductor Strain Gauges Used in Hopkinson Bar Tests
    Miao, Y.
    Gou, X.
    Sheikh, M. Z.
    EXPERIMENTAL TECHNIQUES, 2018, 42 (06) : 623 - 629
  • [8] A Technique for In-Situ Calibration of Semiconductor Strain Gauges Used in Hopkinson Bar Tests
    Y. Miao
    X. Gou
    M.Z. Sheikh
    Experimental Techniques, 2018, 42 : 623 - 629
  • [9] Validation of analytical formulae for the efficiency calibration of gamma detectors used in laboratory and in-situ measurements
    Abbas, Mahmoud I.
    APPLIED RADIATION AND ISOTOPES, 2006, 64 (12) : 1661 - 1664
  • [10] A Method for In-situ Testing and Calibration of Moving-coil Geophones
    Zeng, Ran
    Zhao, Yujiang
    Lin, Jun
    THERMAL, POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 732-733 : 1188 - 1192