Patient exposure to X-ray radiation during abdominal aorta and lower limb digital subtraction angiography

被引:0
|
作者
Juszkat, Robert [1 ]
Blaszak, Madgalena A. [2 ]
Majewska, Natalia [1 ]
Majewski, Waclaw [3 ]
机构
[1] K Marcinkowski Med Univ, Dept Radiol, Poznan, Poland
[2] Adam Mickiewicz Univ, Fac Phys, Poznan, Poland
[3] K Marcinkowski Med Univ, Gen & Vasc Surg, Poznan, Poland
关键词
dosimetry; radiation; dose;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The main aim of this study was to find out what is the risk caused by ionizing radiation during digital subtraction angiography (DSA) for abdominal aorta and lower limb examinations. Material\Methods: The study is based on a large group of patient data subjected to a complex analysis of fluoroscopy time, exposure time, air kerma values, and dose-area product (DAP). Measurements were performed on 449 patients with intra-arterial (IA DSA) contrast administration. Results and Conclusions: Median DAP value for fluoroscopy was 5.4 Gy-cm(2) and for exposure 51.7 Gy-cm(2). On exposure the patients received 94% of the total DAP although this examination takes only 0.1% of the total examination time. For this reason, small changes in the exposure time may result in a considerable reduction in the radiation received by the patient. There was good correlation between DAP values and the fluoroscopy time (r=0.78), while the correlation between DAP and the exposure time was much poorer (r=0.39). It was also found that gender was a differentiating factor neither both fluoroscopy (F[1, 449]=0.01, p>0.05) nor exposure time (F[ 1, 449]=0.42, p>0.05).
引用
收藏
页码:21 / 24
页数:4
相关论文
共 50 条
  • [1] DIGITAL VIDEO SUBTRACTION ANGIOGRAPHY (DVSA) OF THE ABDOMINAL-AORTA AND THE PELVIC AND LOWER-LIMB ARTERIES
    HARDER, T
    JANSON, R
    LACKNER, K
    FRANKEN, T
    FISCHER, P
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1983, 138 (03): : 301 - 309
  • [2] X-RAY MONOCHROMATOR FOR DIGITAL SUBTRACTION ANGIOGRAPHY USING SYNCHROTRON RADIATION
    BARSUKOV, VP
    DOLBNYA, IP
    KOLOKOLNIKOV, YM
    KURYLO, SG
    MEZENTSEV, NA
    PINDYURIN, VF
    SHEROMOV, MA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 308 (1-2): : 419 - 422
  • [3] Digital variance angiography allows about 70% decrease of DSA-related radiation exposure in lower limb X-ray angiography
    Gyano, Marcell
    Berczeli, Marton
    Csobay-Novak, Csaba
    Szollosi, David
    Orias, Viktor, I
    Gog, Istvan
    Kiss, Janos P.
    Veres, Daniel S.
    Szigeti, Krisztian
    Osvath, Szabolcs
    Pataki, Akos
    Juhasz, Viktoria
    Olah, Zoltan
    Sotonyi, Peter
    Nemes, Balazs
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [4] Digital variance angiography allows about 70% decrease of DSA-related radiation exposure in lower limb X-ray angiography
    Marcell Gyánó
    Márton Berczeli
    Csaba Csobay-Novák
    Dávid Szöllősi
    Viktor I. Óriás
    István Góg
    János P. Kiss
    Dániel S. Veres
    Krisztián Szigeti
    Szabolcs Osváth
    Ákos Pataki
    Viktória Juhász
    Zoltán Oláh
    Péter Sótonyi
    Balázs Nemes
    Scientific Reports, 11
  • [5] RADIATION EXPOSURE OF PERSONNEL DURING DIGITAL SUBTRACTION ANGIOGRAPHY
    BRITTON, CA
    WHOLEY, MH
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1988, 11 (02) : 108 - 110
  • [6] EXPOSURE OF PERSONNEL TO RADIATION DURING DIGITAL SUBTRACTION ANGIOGRAPHY
    BRITTON, CA
    WHOLEY, MH
    INVESTIGATIVE RADIOLOGY, 1986, 21 (09) : S42 - S42
  • [7] The application of ICA to the X-ray digital subtraction angiography
    Tang, Songyuan
    Wang, Yongtian
    Chen, Yen-wei
    ADVANCES IN NEURAL NETWORKS - ISNN 2007, PT 2, PROCEEDINGS, 2007, 4492 : 979 - +
  • [8] DOSE-AREA PRODUCT OF PATIENTS UNDERGOING DIGITAL SUBTRACTION ANGIOGRAPHY (DSA): ABDOMINAL AORTA AND LOWER LIMB EXAMINATIONS
    Juszkat, R.
    Blaszak, M. A.
    Majewska, N.
    Majewski, W.
    HEALTH PHYSICS, 2009, 96 (01): : 13 - 18
  • [9] Comparison of two-dimensional MR digital subtraction angiography of the lower extremity with x-ray angiography
    Winchester, PA
    Lee, HM
    Khilnani, NM
    Wang, Y
    Trost, DW
    Bush, HL
    Sos, TA
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 9 (06) : 891 - 899
  • [10] NONINVASIVE DIGITAL ENERGY SUBTRACTION ANGIOGRAPHY WITH A CHANNELING-RADIATION X-RAY SOURCE
    GARY, CK
    PIESTRUP, MA
    BOYERS, DG
    PINCUS, CI
    PANTELL, RH
    ROTHBART, GB
    MEDICAL PHYSICS, 1993, 20 (05) : 1527 - 1535