Patient exposure to X-ray radiation during abdominal aorta and lower limb digital subtraction angiography

被引:0
|
作者
Juszkat, Robert [1 ]
Blaszak, Madgalena A. [2 ]
Majewska, Natalia [1 ]
Majewski, Waclaw [3 ]
机构
[1] K Marcinkowski Med Univ, Dept Radiol, Poznan, Poland
[2] Adam Mickiewicz Univ, Fac Phys, Poznan, Poland
[3] K Marcinkowski Med Univ, Gen & Vasc Surg, Poznan, Poland
关键词
dosimetry; radiation; dose;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The main aim of this study was to find out what is the risk caused by ionizing radiation during digital subtraction angiography (DSA) for abdominal aorta and lower limb examinations. Material\Methods: The study is based on a large group of patient data subjected to a complex analysis of fluoroscopy time, exposure time, air kerma values, and dose-area product (DAP). Measurements were performed on 449 patients with intra-arterial (IA DSA) contrast administration. Results and Conclusions: Median DAP value for fluoroscopy was 5.4 Gy-cm(2) and for exposure 51.7 Gy-cm(2). On exposure the patients received 94% of the total DAP although this examination takes only 0.1% of the total examination time. For this reason, small changes in the exposure time may result in a considerable reduction in the radiation received by the patient. There was good correlation between DAP values and the fluoroscopy time (r=0.78), while the correlation between DAP and the exposure time was much poorer (r=0.39). It was also found that gender was a differentiating factor neither both fluoroscopy (F[1, 449]=0.01, p>0.05) nor exposure time (F[ 1, 449]=0.42, p>0.05).
引用
收藏
页码:21 / 24
页数:4
相关论文
共 50 条
  • [41] Interleaved x-ray imaging: A method for simultaneous acquisition of quantitative and diagnostic digital subtraction angiography
    Whitehead, Joseph F.
    Hoffman, Carson A.
    Wagner, Martin G.
    Minesinger, Grace M.
    Nikolau, Ethan P.
    Laeseke, Paul F.
    Speidel, Michael A.
    MEDICAL PHYSICS, 2024, 51 (04) : 2468 - 2478
  • [42] A high-precision contrast injector for small animal X-ray digital subtraction angiography
    De Lin, Ming
    Ning, Lutao
    Badea, Cristian T.
    Mistry, Nilesh N.
    Qi, Yi
    Johnson, G. Allan
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (03) : 1082 - 1091
  • [43] Digital Subtraction Angiography of Cerebral Arteries: Influence of Cranial Dimensions on X-ray Tube Performance
    Modlinska, Sandra
    Czogalik, Lukasz
    Rojek, Marcin
    Dudek, Piotr
    Janik, Michal
    Mielcarska, Sylwia
    Kufel, Jakub
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (10)
  • [44] Inverse Compton radiation: a novel x-ray source for K-edge subtraction angiography?
    Paterno, G.
    Cardarelli, P.
    Gambaccini, M.
    Serafini, L.
    Petrillo, V
    Drebot, I
    Taibi, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (18):
  • [45] Patient radiation dose from computed tomography angiography and digital subtraction angiography of the brain
    Netwong, Y.
    Krisanachinda, A.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [46] X-ray digital subtraction angiography to magnetic resonance-digital subtraction angiography using three-dimensional TRICKS - Historical perspective and computer simulations: A review
    Mistretta, CA
    Grist, TM
    INVESTIGATIVE RADIOLOGY, 1998, 33 (09) : 496 - 505
  • [47] X-RAY EXPOSURE AND RADIATION PROTECTION IN X-RAY DIAGNOSTICS
    SCHMIDT, T
    ATOMKERNENERGIE, 1973, 22 (02): : 129 - 133
  • [48] RADIATION EXPOSURE DURING DIGITAL INTRAVENOUS ANGIOGRAPHY
    SEEGER, JF
    WESTERMAN, BR
    CARMODY, RF
    SMITH, JRL
    OVITT, TW
    POST, J
    RADIOLOGY, 1982, 144 (04) : 947 - 947
  • [49] 3D gadolinium-enhanced subtraction MR imaging angiography of the lower limb arteries compared to X-ray angiography for evaluation of vascular occlusive disease
    Bendib, K
    Vaudoux, M
    Croisille, P
    Berthezene, Y
    Douek, P
    RADIOLOGY, 1997, 205 : 1361 - 1361
  • [50] The evaluation of lower limb arteriopathy by multidetector computed tomography compared with digital subtraction angiography
    Ferrer, Ma D.
    Revert, A. J.
    Pallardo, Y.
    Esteban, E.
    Jornet, J.
    Molla, E.
    RADIOLOGIA, 2006, 48 (06): : 369 - 374