Patient exposure to X-ray radiation during abdominal aorta and lower limb digital subtraction angiography

被引:0
|
作者
Juszkat, Robert [1 ]
Blaszak, Madgalena A. [2 ]
Majewska, Natalia [1 ]
Majewski, Waclaw [3 ]
机构
[1] K Marcinkowski Med Univ, Dept Radiol, Poznan, Poland
[2] Adam Mickiewicz Univ, Fac Phys, Poznan, Poland
[3] K Marcinkowski Med Univ, Gen & Vasc Surg, Poznan, Poland
关键词
dosimetry; radiation; dose;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The main aim of this study was to find out what is the risk caused by ionizing radiation during digital subtraction angiography (DSA) for abdominal aorta and lower limb examinations. Material\Methods: The study is based on a large group of patient data subjected to a complex analysis of fluoroscopy time, exposure time, air kerma values, and dose-area product (DAP). Measurements were performed on 449 patients with intra-arterial (IA DSA) contrast administration. Results and Conclusions: Median DAP value for fluoroscopy was 5.4 Gy-cm(2) and for exposure 51.7 Gy-cm(2). On exposure the patients received 94% of the total DAP although this examination takes only 0.1% of the total examination time. For this reason, small changes in the exposure time may result in a considerable reduction in the radiation received by the patient. There was good correlation between DAP values and the fluoroscopy time (r=0.78), while the correlation between DAP and the exposure time was much poorer (r=0.39). It was also found that gender was a differentiating factor neither both fluoroscopy (F[1, 449]=0.01, p>0.05) nor exposure time (F[ 1, 449]=0.42, p>0.05).
引用
收藏
页码:21 / 24
页数:4
相关论文
共 50 条
  • [21] IMPLEMENTATION OF DIGITAL SUBTRACTION ANGIOGRAPHY WITH A SYNCHROTRON X-RAY BEAM.
    Zeman, H.D.
    Hughes, E.B.
    Campbell, L.E.
    Hofstadter, R.
    Kirk, R.L.
    Krolicki, T.J.
    Rolfe, J.
    Stone, J.P.
    Wilson, S.
    Rubenstein, E.
    Tompson, A.C.
    Walton, J.T.
    IEEE Transactions on Nuclear Science, 1981, NS-29 (01) : 442 - 446
  • [22] Digital subtraction angiography of the abdominal aorta and lower extremities:: Carbon dioxide versus iodinated contrast material
    Oliva, VL
    Denbow, N
    Thérasse, É
    Common, AA
    Harel, C
    Giroux, MF
    Soulez, G
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1999, 10 (06) : 723 - 731
  • [23] Radiation Exposure Reduction by Digital Variance Angiography in Lower Limb Angiography: A Randomized Controlled Trial
    Sotonyi, Peter
    Berczeli, Marton
    Gyano, Marcell
    Legeza, Peter
    Mihaly, Zsuzsanna
    Csobay-Novak, Csaba
    Pataki, Akos
    Juhasz, Viktoria
    Gog, Istvan
    Szigeti, Krisztian
    Osvath, Szabolcs
    Kiss, Janos P.
    Nemes, Balazs
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2023, 10 (05)
  • [24] Staff and patient exposure to X-ray radiation during cardiac procedures
    Jankowski, J.
    Papierz, S.
    Domienik, J.
    Kacprzyk, J.
    Tybor-Czerwinska, Maja
    Werduch, A.
    POLISH JOURNAL OF RADIOLOGY, 2008, 73 (01) : 40 - 43
  • [25] Radiation exposure of the patient during x-ray examination with the ProScan chest x-ray survey unit
    Gurzhiev A.N.
    Gurzhiev S.N.
    Korablev V.M.
    Kostritskii A.V.
    Alekseev A.G.
    Pikalov V.A.
    Biomedical Engineering, 2008, 42 (5) : 226 - 232
  • [26] PULSED X-RAY SOURCE FOR NON-INVASIVE DIGITAL SUBTRACTION ANGIOGRAPHY
    WIEDEMANN, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (05) : 3308 - 3310
  • [27] Conventional digital subtraction x-ray angiography versus magnetic resonance angiography in the evaluation of carotid disease: patient satisfaction and preferences
    Hoggard, N
    CLINICAL RADIOLOGY, 2004, 59 (04) : 356 - 357
  • [28] Radiation exposure to interventional radiologists during manual-injection digital subtraction angiography
    Nobushige Hayashi
    Toyohiko Sakai
    Manabu Kitagawa
    Rika Inagaki
    Toru Yamamoto
    Tetsuya Fukushima
    Yasushi Ishii
    CardioVascular and Interventional Radiology, 1998, 21 : 240 - 243
  • [29] Radiation exposure to interventional radiologists during manual-injection digital subtraction angiography
    Hayashi, N
    Sakai, T
    Kitagawa, M
    Inagaki, R
    Yamamoto, F
    Fukushima, T
    Ishii, Y
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 21 (03) : 240 - 243
  • [30] PATIENT X-RAY EXPOSURE DURING FLUOROSCOPY
    ARDRAN, GM
    PHYSICS IN MEDICINE AND BIOLOGY, 1968, 13 (03): : 469 - &