The application of ICA to the X-ray digital subtraction angiography

被引:0
|
作者
Tang, Songyuan [1 ,2 ]
Wang, Yongtian [1 ]
Chen, Yen-wei [2 ]
机构
[1] Beijing Inst Technol, Dept Optoelect Engn, Beijing 100081, Peoples R China
[2] Ritsumeikan Univ, Coll Informat Sci & Engn, Kusatsu, Japan
关键词
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The traditional enhancement of X-ray digital subtraction angiography (DSA) is to subtract the mask image and living image so as to remove the back-ground such as ribs, spine, cathers, organs and etc, and obtain the enhanced vessel trees. However, the DSA have serious motion artifacts, poor local contrast and noises, when subtraction technique is used, some tiny vessels are broken, and even disappeared when visualized. To attack the problem, we use independent component analysis instead of subtraction technique. This technique is proved to be very efficient to enhance vessels. Experimental results of simulated data and several clinical data show that the proposed method is robust and can obtain good vessel trees.
引用
收藏
页码:979 / +
页数:2
相关论文
共 50 条
  • [1] Application of ICA to X-ray coronary digital subtraction angiography
    Tang, Songyuan
    Wang, Yongtian
    Chen, Yen-Wei
    NEUROCOMPUTING, 2012, 79 : 168 - 172
  • [2] Automation system of X-ray filter in digital subtraction angiography
    Akaishi, T
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1998, 57 (1-2) : 111 - 114
  • [3] The use of gadolinium chelates for x-ray digital subtraction angiography
    Wagner, HJ
    Kalinowski, M
    Klose, KJ
    Alfke, H
    INVESTIGATIVE RADIOLOGY, 2001, 36 (05) : 257 - 265
  • [4] X-RAY MONOCHROMATOR FOR DIGITAL SUBTRACTION ANGIOGRAPHY USING SYNCHROTRON RADIATION
    BARSUKOV, VP
    DOLBNYA, IP
    KOLOKOLNIKOV, YM
    KURYLO, SG
    MEZENTSEV, NA
    PINDYURIN, VF
    SHEROMOV, MA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 308 (1-2): : 419 - 422
  • [5] Blur invariant phase correlation in X-ray digital subtraction angiography
    Tang, Songyaan
    Wang, Yongtian
    Chen, Yen-Wei
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 1715 - +
  • [6] IMPLEMENTATION OF DIGITAL SUBTRACTION ANGIOGRAPHY WITH A SYNCHROTRON X-RAY BEAM.
    Zeman, H.D.
    Hughes, E.B.
    Campbell, L.E.
    Hofstadter, R.
    Kirk, R.L.
    Krolicki, T.J.
    Rolfe, J.
    Stone, J.P.
    Wilson, S.
    Rubenstein, E.
    Tompson, A.C.
    Walton, J.T.
    IEEE Transactions on Nuclear Science, 1981, NS-29 (01) : 442 - 446
  • [8] Comparison of two-dimensional MR digital subtraction angiography of the lower extremity with x-ray angiography
    Winchester, PA
    Lee, HM
    Khilnani, NM
    Wang, Y
    Trost, DW
    Bush, HL
    Sos, TA
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 9 (06) : 891 - 899
  • [9] NONINVASIVE DIGITAL ENERGY SUBTRACTION ANGIOGRAPHY WITH A CHANNELING-RADIATION X-RAY SOURCE
    GARY, CK
    PIESTRUP, MA
    BOYERS, DG
    PINCUS, CI
    PANTELL, RH
    ROTHBART, GB
    MEDICAL PHYSICS, 1993, 20 (05) : 1527 - 1535
  • [10] A shape-based segmentation algorithm for X-ray digital subtraction angiography images
    Franchi, Danilo
    Gallo, Pasquale
    Marsili, Luca
    Placidi, Giuseppe
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2009, 94 (03) : 267 - 278