A COMPARISON OF THE DIMENSIONS OF A TRUNCATED CONE MEASURED WITH VARIOUS TECHNIQUES - THE CONE MEASUREMENT PROJECT

被引:0
|
作者
MACKAY, ME [1 ]
DICK, GK [1 ]
机构
[1] UNIV QUEENSLAND,DEPT ENGN MECH,METROL LAB,BRISBANE,QLD 4072,AUSTRALIA
关键词
D O I
10.1122/1.550650
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
A mock truncated cone was manufactured and sent to 12 participants throughout the world for measurement of appropriate dimensions. The results indicated that the error in measuring the cone diameter was trivial while the cone angle and truncation height had errors of ±4.79% and ± 12.4%, respectively, based on the standard deviation of all measurements. Two groups had reported values of the cone angle which were statistically high and when these values were ignored the error in the cone angle was reduced to ± 1.38%. These errors are lower than previously quoted accuracies in the literature. Since the measurement techniques used for the five most accurate measurements are not new, it is concluded that care of the person performing the measurement is critical. The effect of errors on the geometric variables’ values on the shear rate, shear stress, and first normal stress difference are discussed. © 1995, The Society of Rheology. All rights reserved.
引用
收藏
页码:673 / 677
页数:5
相关论文
共 50 条
  • [1] Comparison of barreling in unlubricated truncated cone billets during cold upset forging of various metals
    Narayanasamy, R.
    Abu Thaheer, A. Syed
    Baskaran, K.
    INDIAN JOURNAL OF ENGINEERING AND MATERIALS SCIENCES, 2006, 13 (03) : 202 - 208
  • [2] Comparison of barreling in lubricated truncated cone billets during cold upset forging of various metals
    Abu Thaheer, A. Syed
    Narayanasamy, R.
    MATERIALS & DESIGN, 2008, 29 (05) : 1027 - 1035
  • [3] Condensing efficiency of the truncated cone condenser and its comparison with the Winston cone condenser in terahertz region
    Aoki, Makoto
    Hiromoto, Norihisa
    INFRARED PHYSICS & TECHNOLOGY, 2015, 68 : 15 - 18
  • [4] Charge distribution measurement on a truncated cone spacer under dc voltage
    Kumada, A
    Okabe, S
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2004, 11 (06) : 929 - 938
  • [5] Measurement of cone density in the human retina by undersampling techniques
    Pons, A. M.
    Lorente, A.
    Malo, J.
    Artigas, J. M.
    PERCEPTION, 1996, 25 : 112 - 112
  • [6] COMPARISON OF MEASURED AND BACK ESTIMATED CONE PENETRATION RESISTANCE OF SAND
    Gui, Meen-Wah
    Jeng, Dong-Sheng
    PROCEEDINGS OF THE 27TH INTERNATIONAL CONFERENCE ON OFFSHORE MECHANICS AND ARCHTIC ENGINEERING - 2008, VOL 4, 2008, : 371 - 378
  • [7] Comparison of two single-cone obturation techniques
    Araquam, Karolline Rodrigues
    Borges Britto, Maria Leticia
    Nabeshima, Cleber Keiti
    ENDO-ENDODONTIC PRACTICE TODAY, 2011, 5 (02): : 133 - 137
  • [8] Comparison of cone directionality determined by psychophysical and reflectometric techniques
    He, JC
    Marcos, S
    Burns, SA
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1999, 16 (10): : 2363 - 2369
  • [9] Analysis on Measurement Errors of Critical Dimensions of HSK Cone and Its Application
    Chen, W. H.
    Wang, S. L.
    You, R. H.
    MEASUREMENT TECHNOLOGY AND ITS APPLICATION, PTS 1 AND 2, 2013, 239-240 : 611 - 616
  • [10] Comparison of spherical and truncated cone geometries for single abrasive-grain cutting
    Anderson, D.
    Warkentin, A.
    Bauer, R.
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2012, 212 (09) : 1946 - 1953