Evaluation of the Elecsys Syphilis Immunoassay for Detection of Syphilis in Populations at Risk of Disease in the US and Argentina

被引:2
|
作者
Christenson, Robert H. [1 ]
Lessig, Marvin [2 ]
Miles, Gabrielle [3 ]
Luebcke, Silke [4 ]
Stillions, Cheryl [3 ]
Jones, Prentiss [5 ]
机构
[1] Univ Maryland, Sch Med, Dept Pathol, Baltimore, MD 21201 USA
[2] Nationwide Lab Serv, Plantation, FL USA
[3] Roche Diagnost Operat, Global Med & Sci Affairs CPS, Indianapolis, IN USA
[4] Roche Diagnost GmbH, R&D, Penzberg, Germany
[5] Western Michigan Univ, Dept Biomed Sci, Homer Stryker MD Sch Med, Kalamazoo, MI 49008 USA
来源
关键词
D O I
10.1373/jalm.2017.024943
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The Elecsys (R) syphilis immunoassay is an automated, qualitative immunoassay that uses a double-antigen sandwich format to detect antibodies to Treponema pallidum in human serum and plasma. We aimed to validate performance of the immunoassay in various populations at risk for syphilis infection in the US and Argentina. Methods: Samples were obtained for a number of study cohorts, including participants from routine syphilis testing at high or low risk for syphilis, HIV-positive patients, pregnant women, and patients in various stages of syphilis infection. The primary objective was to validate the Elecsys syphilis immunoassay by comparing it with a composite testing algorithm using US Food and Drug Administration (FDA)-approved tests, including the predicate IMMULITE 2000 syphilis screening assay, the rapid plasma reagin, and the T. pallidum particle agglutination assay. Results: Complete algorithm testing was performed on all 2660 collected samples. Acceptable precision was demonstrated in all samples. Comparison of the Elecsys syphilis immunoassay with the final syphilis status for all samples yielded a diagnostic sensitivity of 99.5% (95% CI, 98.21-99.94) and a diagnostic specificity of 99.2% (95% CI, 98.69 -99.49). Overall, the lower limit of the 95% Cls for sensitivity and specificity met the expected performance of >= 95%. Conclusion: This is the first study that confirms the high sensitivity and specificity of the Elecsys syphilis immunoassay in US and Argentinian cohorts and highlights the assay's usefulness as an alternative to current tests for the diagnosis of syphilis infection in a broad range of participant cohorts.
引用
收藏
页码:89 / 99
页数:11
相关论文
共 50 条
  • [21] EVALUATION OF THE DCL SYPHILIS-G ENZYME-IMMUNOASSAY TEST KIT FOR THE SEROLOGIC DIAGNOSIS OF SYPHILIS
    NAYAR, R
    CAMPOS, JM
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1993, 99 (03) : 282 - 285
  • [22] Evaluation of the Vitros Syphilis TPA Chemiluminescence Immunoassay as a First-Line Method for Reverse Syphilis Screening
    Gonzalez, Victoria
    Fernandez, Gema
    Dopico, Eva
    Margall, Nuria
    Esperalba, Juliana
    Munoz, Carme
    Castro, Elisabeth
    Sulleiro, Elena
    Matas, Lurdes
    JOURNAL OF CLINICAL MICROBIOLOGY, 2015, 53 (04) : 1361 - 1364
  • [23] SYPHILIS DETECTION IN CEREBROVASCULAR-DISEASE
    KELLEY, RE
    BELL, L
    KELLEY, SE
    LEE, SC
    STROKE, 1989, 20 (02) : 230 - 234
  • [25] Syphilis in a blood bank in Argentina: Prevalence trends and risk factors
    Rios Trevisan, Ana
    Fernandez, Carolina
    Puppo, Monica
    Remesar, Mirta Cristina
    Roel, Macarena
    Kuperman, Silvina
    TRANSFUSION MEDICINE, 2025,
  • [26] Evaluation of the utility of a rapid test for syphilis at a sexually transmitted disease clinic in Buenos Aires, Argentina
    Lucía Gallo Vaulet
    Nicolás Morando
    Ricardo Casco
    Asunta Melgar
    Silvia Nacher
    Marcelo Rodríguez Fermepin
    María A. Pando
    Scientific Reports, 8
  • [27] SYPHILIS AND THE US ARMY, NEW CONCERNS FOR AN OLD DISEASE
    Garges, Eric
    Clark, Leslie
    Jordan, Nikki
    Leamer, Nicole
    Gaydos, Joel
    SEXUALLY TRANSMITTED DISEASES, 2014, 41 : S66 - S67
  • [28] Evaluation of the utility of a rapid test for syphilis at a sexually transmitted disease clinic in Buenos Aires, Argentina
    Vaulet, Lucia Gallo
    Morando, Nicolas
    Casco, Ricardo
    Melgar, Asunta
    Nacher, Silvia
    Rodriguez Fermepin, Marcelo
    Pando, Maria A.
    SCIENTIFIC REPORTS, 2018, 8
  • [29] Evaluation of chemiluminescence immunoassay as a screening test for syphilis on blood donor samples
    Gupta, Cherry
    Mittal, Kshitija
    Kaur, Ravneet
    Kaur, Jasbinder
    Sood, Tanvi
    Kaur, Gagandeep
    Kaur, Paramjit
    TRANSFUSION AND APHERESIS SCIENCE, 2023, 62 (06)
  • [30] Vitros® 5600 Syphilis TPA assay: evaluation of an automated immunometric immunoassay for detection of Treponema pallidum antibodies
    Van den Bossche, D.
    Van Hoyweghen, C.
    Abdul, M.
    Meersman, K.
    Crucitti, T.
    Van Esbroeck, M.
    ACTA CLINICA BELGICA, 2014, 69 : 22 - 23