Evaluation of the Elecsys Syphilis Immunoassay for Detection of Syphilis in Populations at Risk of Disease in the US and Argentina

被引:2
|
作者
Christenson, Robert H. [1 ]
Lessig, Marvin [2 ]
Miles, Gabrielle [3 ]
Luebcke, Silke [4 ]
Stillions, Cheryl [3 ]
Jones, Prentiss [5 ]
机构
[1] Univ Maryland, Sch Med, Dept Pathol, Baltimore, MD 21201 USA
[2] Nationwide Lab Serv, Plantation, FL USA
[3] Roche Diagnost Operat, Global Med & Sci Affairs CPS, Indianapolis, IN USA
[4] Roche Diagnost GmbH, R&D, Penzberg, Germany
[5] Western Michigan Univ, Dept Biomed Sci, Homer Stryker MD Sch Med, Kalamazoo, MI 49008 USA
来源
关键词
D O I
10.1373/jalm.2017.024943
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The Elecsys (R) syphilis immunoassay is an automated, qualitative immunoassay that uses a double-antigen sandwich format to detect antibodies to Treponema pallidum in human serum and plasma. We aimed to validate performance of the immunoassay in various populations at risk for syphilis infection in the US and Argentina. Methods: Samples were obtained for a number of study cohorts, including participants from routine syphilis testing at high or low risk for syphilis, HIV-positive patients, pregnant women, and patients in various stages of syphilis infection. The primary objective was to validate the Elecsys syphilis immunoassay by comparing it with a composite testing algorithm using US Food and Drug Administration (FDA)-approved tests, including the predicate IMMULITE 2000 syphilis screening assay, the rapid plasma reagin, and the T. pallidum particle agglutination assay. Results: Complete algorithm testing was performed on all 2660 collected samples. Acceptable precision was demonstrated in all samples. Comparison of the Elecsys syphilis immunoassay with the final syphilis status for all samples yielded a diagnostic sensitivity of 99.5% (95% CI, 98.21-99.94) and a diagnostic specificity of 99.2% (95% CI, 98.69 -99.49). Overall, the lower limit of the 95% Cls for sensitivity and specificity met the expected performance of >= 95%. Conclusion: This is the first study that confirms the high sensitivity and specificity of the Elecsys syphilis immunoassay in US and Argentinian cohorts and highlights the assay's usefulness as an alternative to current tests for the diagnosis of syphilis infection in a broad range of participant cohorts.
引用
收藏
页码:89 / 99
页数:11
相关论文
共 50 条
  • [31] Evaluation of the Determine Syphilis TP assay for the detection of antibodies against Treponema pallidum for the serodiagnosis of syphilis
    Y.-H. Zhuang
    Y. Tian
    Y. Chen
    J. Tang
    J.-Q. Wang
    P. Li
    Q. Li
    Y.-Q. Jiang
    European Journal of Clinical Microbiology & Infectious Diseases, 2012, 31 : 929 - 935
  • [32] Evaluation of the Determine Syphilis TP assay for the detection of antibodies against Treponema pallidum for the serodiagnosis of syphilis
    Zhuang, Y-H
    Tian, Y.
    Chen, Y.
    Tang, J.
    Wang, J-Q
    Li, P.
    Li, Q.
    Jiang, Y-Q
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2012, 31 (06) : 929 - 935
  • [33] Performance Evaluation of a Fully Automated Immunoassay for the Detection of Human Growth Hormone on the Elecsys® Immunoassay System
    van Helden, Josef
    Hermsen, Derek
    von Ahsen, Nicholas
    Bidlingmaier, Martin
    CLINICAL LABORATORY, 2014, 60 (10) : 1641 - 1651
  • [34] Detection and follow up of infants at risk of congenital syphilis
    Sothinathan, U.
    Hannam, S.
    Fowler, A.
    Zuckerman, M.
    Reeves, I.
    Tenant-Flowers, M.
    ARCHIVES OF DISEASE IN CHILDHOOD, 2006, 91 (07) : 620 - 620
  • [35] SYPHILIS DIAGNOSTIC TEST OF STANDARD™ Q SYPHILIS AB USING FINGERPRICK WHOLE BLOOD AND SERUM ON HIGH RISK POPULATIONS
    Lubis, Rahma
    Sirait, Sondang
    Agustin, Triana
    Indriatmi, Wresti
    SEXUALLY TRANSMITTED INFECTIONS, 2019, 95 : A322 - A323
  • [36] Evaluation of the Boson Chemiluminescence Immunoassay as a First-Line Screening Test in the ECDC Algorithm for Syphilis Serodiagnosis in a Population with a High Prevalence of Syphilis
    Qiu, Xin-Hui
    Zhang, Ya-Feng
    Chen, Yu-Yan
    Zhang, Qiao
    Chen, Fu-Yi
    Liu, Long
    Fan, Jin-Yi
    Gao, Kun
    Zhu, Xiao-Zhen
    Zheng, Wei-Hong
    Zhang, Hui-Lin
    Lin, Li-Rong
    Liu, Li-Li
    Tong, Man-Li
    Zhang, Chang-Gong
    Niu, Jian-Jun
    Yang, Tian-Ci
    JOURNAL OF CLINICAL MICROBIOLOGY, 2015, 53 (04) : 1371 - 1374
  • [37] Evaluation and Treatment of Congenital Syphilis: A National Survey of US Pediatric Specialists
    Banks, David B.
    Flores, John M.
    Paredes, Jose Luis
    Parzen-Johnson, Simon L.
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (20)
  • [38] Evaluation of the Lumipulse G TP-N Chemiluminescent Immunoassay as a Syphilis Screening Test
    Ortiz, Daniel A.
    Loeffelholz, Michael J.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2017, 55 (11) : 3236 - 3241
  • [39] EVALUATION OF AN ENZYME-IMMUNOASSAY FOR IGM ANTIBODIES TO TREPONEMA-PALLIDUM IN SYPHILIS IN MAN
    MULLER, F
    MOSKOPHIDIS, M
    BRITISH JOURNAL OF VENEREAL DISEASES, 1984, 60 (05): : 288 - 292
  • [40] EVALUATION OF A TREPONEMA-PALLIDUM ENZYME-IMMUNOASSAY AS A SCREENING-TEST FOR SYPHILIS
    HOOPER, NE
    MALLOY, DC
    PASSEN, S
    CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 1994, 1 (04) : 477 - 481