Establishing minimum free chlorine residual concentration for microbial control in a municipal drinking water distribution system

被引:3
|
作者
Rand, Jennie L. [1 ]
Gagnon, Graham A. [2 ]
Knowles, Alisha [3 ]
机构
[1] Acad Univ, Ivan Curry Sch Engn, Wolfville, NS B4P 2R6, Canada
[2] Dalhousie Univ, Dept Civil & Resource Engn, Halifax, NS B3H 4R2, Canada
[3] Halifax Water, Water Qual, Halifax, NS B3K 5M1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Chlorine; Disinfection Residual; Distribution System; Heterotrophic Bacteria; Municipal Water Supply; Regulations;
D O I
10.2166/wpt.2014.055
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
Distribution system data from a Nova Scotia municipal drinking water supply was collected over four years, including free chlorine residual concentration, heterotrophic plate count (HPC) bacteria, and temperature. These data were analyzed for occurrences of HPC bacteria greater than 500 colony forming units (CFU)/mL. The municipality was interested in determining if secondary chlorination practices were sufficient in maintaining microbial health in their distribution system. Coliform data were non-detect (total coliforms and Escherichia coli) in the distribution system over this period and thus heterotrophic bacteria were used to assess microbial health. Results were compared to similar data collected from pilot-scale studies that had been carried out using the same municipal water as the source. Analysis showed that a similar trend was observed between pilot-and full-scale samples. Full-scale data analysis revealed that the minimum disinfection requirement of 0.2 mg/L did not consistently control occurrences of heterotrophic bacteria from being greater than 500 CFU/mL. By comparison, maintaining a concentration of 0.3 mg/L or above, particularly in warm-weather systems, maintained the number of heterotrophic bacteria at below 500 CFU/mL. Fortunately the majority of samples collected in the full-scale distribution system (> 89%) had a free chlorine residual concentration of greater than 0.30 mg/L. While it is recognized that this system had 100% compliance for E. coli, the goal of this work will help utilities understand how to utilize microbial data to inform operational disinfection targets for their distribution system.
引用
收藏
页码:491 / 501
页数:11
相关论文
共 50 条
  • [21] Analyser system for monitoring free chlorine in drinking water
    不详
    FILTRATION & SEPARATION, 2008, 45 (07): : 10 - 10
  • [22] Modelling the behaviour of chlorine within a drinking water distribution system following a microbial contamination event
    Macedo, Dhiogo Okumoto
    Janzen, Johannes Gerson
    URBAN WATER JOURNAL, 2022, 19 (05) : 531 - 537
  • [23] Spatial diversity of chlorine residual in a drinking water distribution system: application of an integrated fuzzy logic technique
    Termini, Donatella
    Viviani, Gaspare
    JOURNAL OF HYDROINFORMATICS, 2015, 17 (02) : 293 - 306
  • [24] Numeric Modelling of the Residual Chlorine Concentration Evolution in a Water Distribution Network
    Perju, Sorin
    Stanescu, Ioana
    REVISTA DE CHIMIE, 2015, 66 (06): : 886 - 890
  • [25] Robust Prediction of Residual Chlorine Decay in a Drinking Water Distribution System Integrating Water Quality Sensing and Predictive Tools
    Jafari, Iman
    Luo, Rongmo
    Ng, Emily
    Corral Jr, Felipe
    Chua, Yixiong
    Ng, Szu Hui
    Hu, Jiangyong
    ACS ES&T WATER, 2024, 4 (12): : 5506 - 5521
  • [26] Fate of free chlorine in drinking water during distribution in premise plumbing
    Zheng, Muzi
    He, Chunguang
    He, Qiang
    ECOTOXICOLOGY, 2015, 24 (10) : 2151 - 2155
  • [27] Fate of free chlorine in drinking water during distribution in premise plumbing
    Muzi Zheng
    Chunguang He
    Qiang He
    Ecotoxicology, 2015, 24 : 2151 - 2155
  • [28] Numerical calculation of chlorine dioxide concentration in drinking water supply system
    Goricanec, D
    Krope, J
    WATER RESOURCES MANAGEMENT II, 2003, 8 : 55 - 64
  • [29] Monitoring of chlorine concentration in drinking water distribution systems using an interval estimator
    Langowski, Rafal
    Brdys, Mietek A.
    INTERNATIONAL JOURNAL OF APPLIED MATHEMATICS AND COMPUTER SCIENCE, 2007, 17 (02) : 199 - 216
  • [30] New model of chlorine-wall reaction for simulating chlorine concentration in drinking water distribution systems
    Fisher, Ian
    Kastl, George
    Sathasivan, Arumugam
    WATER RESEARCH, 2017, 125 : 427 - 437