Establishing minimum free chlorine residual concentration for microbial control in a municipal drinking water distribution system

被引:3
|
作者
Rand, Jennie L. [1 ]
Gagnon, Graham A. [2 ]
Knowles, Alisha [3 ]
机构
[1] Acad Univ, Ivan Curry Sch Engn, Wolfville, NS B4P 2R6, Canada
[2] Dalhousie Univ, Dept Civil & Resource Engn, Halifax, NS B3H 4R2, Canada
[3] Halifax Water, Water Qual, Halifax, NS B3K 5M1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Chlorine; Disinfection Residual; Distribution System; Heterotrophic Bacteria; Municipal Water Supply; Regulations;
D O I
10.2166/wpt.2014.055
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
Distribution system data from a Nova Scotia municipal drinking water supply was collected over four years, including free chlorine residual concentration, heterotrophic plate count (HPC) bacteria, and temperature. These data were analyzed for occurrences of HPC bacteria greater than 500 colony forming units (CFU)/mL. The municipality was interested in determining if secondary chlorination practices were sufficient in maintaining microbial health in their distribution system. Coliform data were non-detect (total coliforms and Escherichia coli) in the distribution system over this period and thus heterotrophic bacteria were used to assess microbial health. Results were compared to similar data collected from pilot-scale studies that had been carried out using the same municipal water as the source. Analysis showed that a similar trend was observed between pilot-and full-scale samples. Full-scale data analysis revealed that the minimum disinfection requirement of 0.2 mg/L did not consistently control occurrences of heterotrophic bacteria from being greater than 500 CFU/mL. By comparison, maintaining a concentration of 0.3 mg/L or above, particularly in warm-weather systems, maintained the number of heterotrophic bacteria at below 500 CFU/mL. Fortunately the majority of samples collected in the full-scale distribution system (> 89%) had a free chlorine residual concentration of greater than 0.30 mg/L. While it is recognized that this system had 100% compliance for E. coli, the goal of this work will help utilities understand how to utilize microbial data to inform operational disinfection targets for their distribution system.
引用
收藏
页码:491 / 501
页数:11
相关论文
共 50 条
  • [41] Effect of Residual Chlorine Concentration on Water Pipe Corrosion and Corrosion Control Plan
    Han, Keum-Seok
    Park, Ju-Hyun
    Park, Young-Bok
    Kim, Seong-Jae
    Kim, Hyen-Don
    Choi, Young-June
    Choi, In-Cheol
    Hong, Seong-Ho
    CORROSION SCIENCE AND TECHNOLOGY-KOREA, 2018, 17 (01): : 12 - 19
  • [42] Microbial characteristics of a distribution system fed with nanofiltered drinking water
    Sibille, I
    Mathieu, L
    Paquin, JL
    Gatel, D
    Block, JC
    WATER RESEARCH, 1997, 31 (09) : 2318 - 2326
  • [43] Effect of sequential UV/free chlorine disinfection on opportunistic pathogens and microbial community structure in simulated drinking water distribution systems
    Liu, Lizhong
    Xing, Xueci
    Hu, Chun
    Wang, Haibo
    Lyu, Lai
    CHEMOSPHERE, 2019, 219 : 971 - 980
  • [44] Residual chlorine behavior in a distribution network of a small water supply system
    Araya, Andres
    Sanchez, Luis D.
    JOURNAL OF WATER SANITATION AND HYGIENE FOR DEVELOPMENT, 2018, 8 (02) : 349 - 358
  • [45] The stress response mechanisms and resistance change of chlorine-resistant microbial community at multi-phase interface under residual antibiotics in drinking water distribution system
    Zhou, Ziyi
    Ma, Wencheng
    Zhong, Dan
    JOURNAL OF CLEANER PRODUCTION, 2024, 438
  • [46] Poor efficacy of residual chlorine disinfectant in drinking water to inactivate waterborne pathogens in distribution systems
    Payment, P
    CANADIAN JOURNAL OF MICROBIOLOGY, 1999, 45 (08) : 709 - 715
  • [48] Optimal Design of Water Distribution Systems Considering Topological Characteristics and Residual Chlorine Concentration
    Ko, Mun Jin
    Choi, Young Hwan
    MATHEMATICS, 2022, 10 (24)
  • [49] Application of Artificial Neural Network for Reducing of Chlorine Residual Concentration in Water Distribution Network
    Koo, Jayong
    Inakazu, Toyono
    Koizumi, Akira
    Arai, Yasuhiro
    Kim, Kyoungpil
    Ahn, Jaechan
    WATER PRACTICE AND TECHNOLOGY, 2008, 3 (02):
  • [50] Migration and Transformation of Ofloxacin by Free Chlorine in Water Distribution System
    Bi, Weiwei
    Jin, Yi
    Wang, Hongyu
    WATER, 2019, 11 (04):