摘要
Accurate modelling of chlorine concentrations throughout a drinking water system needs sound mathematical descriptions of decay mechanisms in bulk water and at pipe walls. Wall-reaction rates along pipelines in three different systems were calculated from differences between field chlorine profiles and accurately modelled bulk decay. Lined pipes with sufficiently large diameters (>500 mm) and higher chlorine concentrations (>0.5 mg/L) had negligible wall-decay rates, compared with bulk decay rates. Further downstream, wall-reaction rate consistently increased (peaking around 0.15 mg/dm(2)/h) as chlorine concentration decreased, until mass-transport to the wall was controlling wall reaction. These results contradict wall-reaction models, including those incorporated in the EPANET software, which assume wall decay is of either zero-order (constant decay rate) or first-order (wall-decay rate reduces with chlorine concentration). Instead, results are consistent with facilitation of the wall reaction by biofilm activity, rather than surficial chemical reactions. A new model of wall reaction combines the effect of biofilm activity moderated by chlorine concentration and mass-transport limitation. This wall reaction model, with an accurate bulk chlorine decay model, is essential for sufficiently accurate prediction of chlorine residuals towards the end of distribution systems and therefore control of microbial contamination. Implementing this model in EPANET-MSX (or similar) software enables the accurate chlorine modelling required for improving disinfection strategies in drinking water networks. New insight into the effect of chlorine on biofilm can also assist in controlling biofilm to maintain chlorine residuals. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:427 / 437
页数:11
相关论文
共 50 条
  • [1] Validity of chlorine-wall reaction models for drinking water distribution systems
    Fisher, Ian
    Kastl, George
    Sathasivan, Arumugam
    URBAN WATER JOURNAL, 2023, 20 (09) : 1157 - 1168
  • [2] Pipe section reactor to evaluate chlorine-wall reaction
    Digiano, FA
    Zhang, WD
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2005, 97 (01): : 74 - 85
  • [3] Monitoring of chlorine concentration in drinking water distribution systems using an interval estimator
    Langowski, Rafal
    Brdys, Mietek A.
    INTERNATIONAL JOURNAL OF APPLIED MATHEMATICS AND COMPUTER SCIENCE, 2007, 17 (02) : 199 - 216
  • [4] Reaction of fleroxacin with chlorine and chlorine dioxide in drinking water distribution systems: Kinetics, transformation mechanisms and toxicity evaluations
    He, Guilin
    Zhang, Tuqiao
    Zheng, Feifei
    Li, Cong
    Zhang, Qingzhou
    Dong, Feilong
    Huang, Yuan
    CHEMICAL ENGINEERING JOURNAL, 2019, 374 : 1191 - 1203
  • [5] A comprehensive bulk chlorine decay model for simulating residuals in water distribution systems
    Fisher, Ian
    Kastl, George
    Sathasivan, Arumugam
    URBAN WATER JOURNAL, 2017, 14 (04) : 361 - 368
  • [6] Chlorine Concentration Modelling and Supervision in Water Distribution Systems
    Perez, Ramon
    Martinez-Torrents, Albert
    Martinez, Manuel
    Grau, Sergi
    Vinardell, Laura
    Tomas, Ricard
    Martinez-Llado, Xavier
    Jubany, Irene
    SENSORS, 2022, 22 (15)
  • [7] Kinetic models of chlorine decay in drinking water distribution systems
    Vasconcelos, JJ
    Boulos, PF
    Clark, RM
    COMPUTER METHODS AND WATER RESOURCES III, 1996, : 413 - 421
  • [8] Simulation of chlorine decay in drinking-water distribution systems
    Ozdemir, ON
    Ucak, A
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2002, 128 (01): : 31 - 39
  • [9] Biofilm Microbiome (Re)Growth Dynamics in Drinking Water Distribution Systems Are Impacted by Chlorine Concentration
    Fish, Katherine E.
    Boxall, Joby B.
    FRONTIERS IN MICROBIOLOGY, 2018, 9
  • [10] AN INTERVAL ESTIMATOR FOR CHLORINE MONITORING IN DRINKING WATER DISTRIBUTION SYSTEMS UNDER UNCERTAIN SYSTEM DYNAMICS, INPUTS AND CHLORINE CONCENTRATION MEASUREMENT ERRORS
    Langowski, Rafal
    Brdys, Mietek A.
    INTERNATIONAL JOURNAL OF APPLIED MATHEMATICS AND COMPUTER SCIENCE, 2017, 27 (02) : 309 - 322