New model of chlorine-wall reaction for simulating chlorine concentration in drinking water distribution systems

被引:56
|
作者
Fisher, Ian [1 ]
Kastl, George [2 ]
Sathasivan, Arumugam [2 ]
机构
[1] Watervale Syst, POB 318, Potts Point, NSW 1335, Australia
[2] Western Sydney Univ, Sch Comp Engn & Math, Locked Bag 1797, Penrith, NSW 2791, Australia
关键词
Chlorine decay model; Wall-reaction rate; Bulk decay; System model; Biofilm; Mass-transport; BULK DECAY; PIPE WALL; TEMPERATURE; PROFILES;
D O I
10.1016/j.watres.2017.08.066
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Accurate modelling of chlorine concentrations throughout a drinking water system needs sound mathematical descriptions of decay mechanisms in bulk water and at pipe walls. Wall-reaction rates along pipelines in three different systems were calculated from differences between field chlorine profiles and accurately modelled bulk decay. Lined pipes with sufficiently large diameters (>500 mm) and higher chlorine concentrations (>0.5 mg/L) had negligible wall-decay rates, compared with bulk decay rates. Further downstream, wall-reaction rate consistently increased (peaking around 0.15 mg/dm(2)/h) as chlorine concentration decreased, until mass-transport to the wall was controlling wall reaction. These results contradict wall-reaction models, including those incorporated in the EPANET software, which assume wall decay is of either zero-order (constant decay rate) or first-order (wall-decay rate reduces with chlorine concentration). Instead, results are consistent with facilitation of the wall reaction by biofilm activity, rather than surficial chemical reactions. A new model of wall reaction combines the effect of biofilm activity moderated by chlorine concentration and mass-transport limitation. This wall reaction model, with an accurate bulk chlorine decay model, is essential for sufficiently accurate prediction of chlorine residuals towards the end of distribution systems and therefore control of microbial contamination. Implementing this model in EPANET-MSX (or similar) software enables the accurate chlorine modelling required for improving disinfection strategies in drinking water networks. New insight into the effect of chlorine on biofilm can also assist in controlling biofilm to maintain chlorine residuals. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:427 / 437
页数:11
相关论文
共 50 条
  • [31] Disinfection of hot drinking water systems by Chlorine dioxide
    Juretzek, T.
    Porta, M. Armengol
    Baer, W.
    INTERNATIONAL JOURNAL OF MEDICAL MICROBIOLOGY, 2008, 298 : 33 - 33
  • [32] Comparative analysis of chlorine dioxide, free chlorine and chloramines on bacterial water quality in model distribution systems
    Gagnon, GA
    O'Leary, KC
    Volk, CJ
    Chauret, C
    Stover, L
    Andrews, RC
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2004, 130 (11) : 1269 - 1279
  • [33] Mixed chlorine/chloramines in disinfected water and drinking water distribution systems (DWDSs): A critical review
    Pan, Renjie
    Zhang, Tian-Yang
    He, Huan
    Zheng, Zheng-Xiong
    Dong, Zheng-Yu
    Zhao, Heng-Xuan
    Xu, Meng-Yuan
    Luo, Zhen-Ning
    Hu, Chen-Yan
    Tang, Yu-Lin
    El-Din, Mohamed Gamal
    Xu, Bin
    WATER RESEARCH, 2023, 247
  • [34] Bulk and pipe wall chlorine degradation kinetics in three water distribution systems
    McGrath, John
    Maleki, Mahnoush
    Bouchard, Christian
    Pelletier, Genevieve
    Rodriguez, Manuel J.
    URBAN WATER JOURNAL, 2021, 18 (07) : 512 - 521
  • [35] Analysis of Free Residual Chlorine in Drinking Water Distribution Systems in Ore Processing Industry
    Susanto, Arif
    Amrina, Uli
    Purwanto, Purwanto
    Putro, Edi
    Yochu, Wiliam
    Wilmot, John
    POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2020, 29 (06): : 4321 - 4330
  • [36] Modeling Residual Chlorine Response to a Microbial Contamination Event in Drinking Water Distribution Systems
    Helbling, Damian E.
    VanBriesen, Jeanne M.
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2009, 135 (10): : 918 - 927
  • [37] Effect of pipe corrosion scales on chlorine dioxide consumption in drinking water distribution systems
    Zhang, Zhe
    Stout, Janet E.
    Yu, Victor L.
    Vidic, Radisav
    WATER RESEARCH, 2008, 42 (1-2) : 129 - 136
  • [38] Effect of free chlorine application on microbial quality of drinking water in chloraminated distribution systems
    Rosenfeldt, Erik J.
    Baeza, Carolina
    Knappe, Detlef R. U.
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2009, 101 (10): : 60 - 70
  • [39] Free chlorine consumption induced by cast iron corrosion in drinking water distribution systems
    Frateur, I
    Deslouis, C
    Kiene, L
    Levi, Y
    Tribollet, B
    WATER RESEARCH, 1999, 33 (08) : 1781 - 1790
  • [40] EFFECTIVITY OF CHLORINE DIOXIDE TO CONTROL AEROMONAS IN DRINKING-WATER DISTRIBUTION-SYSTEMS
    MEDEMA, GJ
    WONDERGEM, E
    VANDIJKLOOYAARD, AM
    HAVELAAR, AH
    WATER SCIENCE AND TECHNOLOGY, 1991, 24 (02) : 325 - 326