Effect of pipe corrosion scales on chlorine dioxide consumption in drinking water distribution systems

被引:83
|
作者
Zhang, Zhe [1 ]
Stout, Janet E. [1 ]
Yu, Victor L. [2 ]
Vidic, Radisav [1 ]
机构
[1] Univ Pittsburgh, Sch Engn, Dept Civil & Environm Engn, Pittsburgh, PA 15261 USA
[2] Univ Pittsburgh, Sch Med, Dept Med, Pittsburgh, PA USA
关键词
chlorine dioxide; corrosion scale; magnetite; cuprite;
D O I
10.1016/j.watres.2007.07.054
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Previous studies showed that temperature and total organic carbon in drinking water would cause chlorine dioxide (ClO2) loss in a water distribution system and affect the efficiency of ClO2 for Legionella control. However, among the various causes Of ClO2 loss in a drinking water distribution system, the loss of disinfectant due to the reaction with corrosion scales has not been studied in detail. In this study, the corrosion scales from a galvanized iron pipe and a copper pipe that have been in service for more than 10 years were characterized by energy dispersive spectroscopy (EDS) and X-ray diffraction (XRD). The impact of these corrosion scale materials on ClO2 decay was investigated in de-ionized water at 2S and 45 degrees C in a batch reactor with floating glass cover. ClO2 decay was also investigated in a specially designed reactor made from the iron and copper pipes to obtain more realistic reaction rate data. Goethite (alpha-FeOOH) and magnetite (Fe3O4) were identified as the main components of iron corrosion scale. Cuprite (Cu2O) was identified as the major component of copper corrosion scale. The reaction rate of ClO2 with both iron and copper oxides followed a first-order kinetics. First-order decay rate constants for ClO2 reactions with iron corrosion scales obtained from the used service pipe and in the iron pipe reactor itself ranged from 0.025 to 0.083 min(-1). The decay rate constant for ClO2 with Cu2O powder and in the copper pipe reactor was much smaller and it ranged from 0.0052 to 0.0062 min(-1). Based on these results, it can be concluded that the corrosion scale will cause much more significant ClO2 loss in corroded iron pipes of the distribution system than the total organic carbon that may be present in finished water. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:129 / 136
页数:8
相关论文
共 50 条
  • [1] Effect of chlorine on corrosion in drinking water systems
    Cantor, AF
    Park, JK
    Vaiyavatjamai, P
    [J]. JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2003, 95 (05): : 112 - 123
  • [2] Free chlorine consumption induced by cast iron corrosion in drinking water distribution systems
    Frateur, I
    Deslouis, C
    Kiene, L
    Levi, Y
    Tribollet, B
    [J]. WATER RESEARCH, 1999, 33 (08) : 1781 - 1790
  • [3] Chlorine consumption due to corrosion in water distribution systems
    Deslouis, C
    Frateur, I
    Tribollet, B
    Kiene, L
    Levi, Y
    [J]. ENERGY AND ELECTROCHEMICAL PROCESSING FOR A CLEANER ENVIRONMENT, 1998, 97 (28): : 481 - 493
  • [4] Characteristics of iron corrosion scales and water quality variations in drinking water distribution systems of different pipe materials
    Li, Manjie
    Liu, Zhaowei
    Chen, Yongcan
    Hai, Yang
    [J]. WATER RESEARCH, 2016, 106 : 593 - 603
  • [5] Chlorine decay in drinking-water transmission and distribution systems: Pipe service age effect
    Al-Jasser, A. O.
    [J]. WATER RESEARCH, 2007, 41 (02) : 387 - 396
  • [6] Pipe Service Age Effect on Chlorine Decay in Drinking-Water Transmission and Distribution Systems
    Al-Jasser, A. O.
    [J]. CLEAN-SOIL AIR WATER, 2011, 39 (09) : 827 - 832
  • [7] Characterization of the bacterial communities and iron corrosion scales in drinking groundwater distribution systems with chlorine/chloramine
    Li, Xiaoxiao
    Wang, Haibo
    Zhang, Yu
    Hu, Chun
    Yang, Min
    [J]. INTERNATIONAL BIODETERIORATION & BIODEGRADATION, 2014, 96 : 71 - 79
  • [8] Effect of biofilm on cast iron pipe corrosion in drinking water distribution system: Corrosion scales characterization and microbial community structure investigation
    Teng, F.
    Guan, Y. T.
    Zhu, W. P.
    [J]. CORROSION SCIENCE, 2008, 50 (10) : 2816 - 2823
  • [9] Pipe Scales and Biofilms in Drinking-Water Distribution Systems: Undermining Finished Water Quality
    Makris, Konstantinos C.
    Andra, Syam S.
    Botsaris, George
    [J]. CRITICAL REVIEWS IN ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2014, 44 (13) : 1477 - 1523
  • [10] Speciation of iron and development of iron corrosion scales in drinking water distribution systems
    Tan, Haoqiang
    He, Wenjie
    Han, Hongda
    Lu, Yingchen
    Zhang, Nan
    [J]. DESALINATION AND WATER TREATMENT, 2015, 56 (03) : 646 - 654