Intraarterial CT Angiography Using Ultra Low Volume of Iodine Contrast - Own Experiences

被引:3
|
作者
Garcarek, Jerzy [1 ]
Kurcz, Jacek [1 ]
Guzinski, Maciej [1 ]
Banasik, Miroslaw [2 ]
Mis, Marcin [1 ]
Golebiowski, Tomasz [2 ]
机构
[1] Wroclaw Med Univ, Dept Gen Radiol Intervent Radiol Ang Neuroradiol, Wroclaw, Poland
[2] Wroclaw Med Univ, Dept Nephrol & Transplantat Med, Wroclaw, Poland
关键词
Angiography; Digital Subtraction; Contrast Media; Gastrointestinal Hemorrhage; Infusions; Intra-Arterial; Kidney Transplantation; Multidetector Computed Tomography;
D O I
10.12659/PJR.894050
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: High volume of intravenous contrast in CT-angiography may result in contrast-induced nephropathy. Intraarterial ultra-low volume of contrast medium results in its satisfactory blood concentration with potentially good image quality. The first main purpose was to assess the influence of the method on function of transplanted kidney in patients with impaired graft function. The second main purpose of the study was to evaluate the usefulness of this method for detection of gastrointestinal and head-and-neck haemorrhages. Material/Methods: Between 2010 and 2013 intraarterial CT-angiography was performed in 56 patients, including 28 with chronic kidney disease (CKD). There were three main subgroups: 18 patients after kidney transplantation, 10 patients with gastrointestinal hemorrhage, 8 patients with head-and-neck hemorrhage. Contralateral or ipsilateral inguinal arterial approach was performed. The 4-French vascular sheaths and 4F-catheters were introduced under fluoroscopy. Intraarterial CT was performed using 64-slice scanner. The scanning protocol was as follows: slice thickness 0.625 mm, pitch 1.3, gantry rotation 0.6 sec., scanning delay 1-2 sec. The extent of the study was established on the basis of scout image. In patients with CKD 6-8 mL of Iodixanol (320 mg/mL) diluted with saline to 18-24 mL was administered at a speed of 4-5 mL/s. Results: Vasculature was properly visualized in all patients. In patients with impaired renal function creatinine/eGFR levels remained stable in all but one case. Traditional arteriography failed and CT-angiography demonstrated the site of bleeding in 3 of 10 patients with symptoms of gastrointestinal bleeding (30%). In 8 patients with head-and-neck bleeding CT-angiography did not prove beneficial when compared to traditional arteriography. Conclusions: 1. Ultra-low contrast intraarterial CT-angiography does not deteriorate the function of transplanted kidneys in patients with impaired graft function. 2. 3D reconstructions allow for excellent visualization of vascular anatomy of renal transplants. 3. Intraarterial CT-angiography is useful for detection of the bleeding site.
引用
收藏
页码:344 / 349
页数:6
相关论文
共 50 条
  • [21] Ultra-low-dose CT coronary angiography using 128-slice dual source CT with low concentration contrast agent: initial experience
    Lei Zhao
    Aishi Liu
    Youmin Guo
    Japanese Journal of Radiology, 2017, 35 : 724 - 732
  • [22] Optimized contrast volume for dynamic CT angiography in renal transplant patients using a multiphase CT protocol
    Helck, A.
    Bamberg, F.
    Sommer, W. H.
    Wessely, M.
    Becker, C.
    Clevert, D. A.
    Notohamiprodjo, M.
    Reiser, M.
    Nikolaou, K.
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (03) : 692 - 698
  • [23] CT Angiography of the Aorta Using Photon-counting Detector CT with Reduced Contrast Media Volume
    Higashigaito, Kai
    Mergen, Victor
    Eberhard, Matthias
    Jungblut, Lisa
    Hebeisen, Monika
    Ratzer, Susan
    Zanini, Bettina
    Kobe, Adrian
    Martini, Katharina
    Euler, Andre
    Alkadhi, Hatem
    RADIOLOGY-CARDIOTHORACIC IMAGING, 2023, 5 (01):
  • [24] Evaluation of Low-kVp Low-Volume Iodinated Contrast Protocol for Coronary CT Angiography Using Retrospective ECG Gating
    Kapoor, Atul
    Mahajan, Goldaa
    Kapoor, Aprajita
    INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2021, 31 (04): : 910 - 916
  • [25] Low or high iodine content of contrast medium for cardiac angiography?
    Waser, M
    Kaufmann, U
    Luescher, T
    Meier, B
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 1998, 11 (02) : 113 - 116
  • [26] CT Angiography of the Aorta: Prospective Evaluation of Individualized Low-Volume Contrast Media Protocols
    Higashigaito, Kai
    Schmid, Tabea
    Puippe, Gilbert
    Morsbach, Fabian
    Lachat, Mario
    Seifert, Burkhardt
    Pfammatter, Thomas
    Alkadhi, Hatem
    Husarik, Daniela B.
    RADIOLOGY, 2016, 280 (03) : 960 - 968
  • [27] Improved enhancement in CT angiography with reduced contrast media iodine concentrations at constant iodine dose
    Van Cauteren, Toon
    Van Gompel, Gert
    Nieboer, Koenraad H.
    Willekens, Inneke
    Evans, Paul
    Macholl, Sven
    Droogmans, Steven
    de Mey, Johan
    Buls, Nico
    SCIENTIFIC REPORTS, 2018, 8
  • [28] Improved enhancement in CT angiography with reduced contrast media iodine concentrations at constant iodine dose
    Toon Van Cauteren
    Gert Van Gompel
    Koenraad H. Nieboer
    Inneke Willekens
    Paul Evans
    Sven Macholl
    Steven Droogmans
    Johan de Mey
    Nico Buls
    Scientific Reports, 8
  • [29] IMPACT OF USING LOW DOSE CONTRAST IN CT ANGIOGRAPHY FOR THE DIAGNOSIS OF PULMONARY EMBOLISM
    Htun, Zin Mar
    Buddharaju, Venkata
    Chowdhuri, Nilarun
    Shahzad, Muhammad
    Krukowski, Adrian
    Salazar, Carlos
    Kc, Arati
    Azim, Ali
    CHEST, 2019, 156 (04) : 1019A - 1020A
  • [30] Multiple Adversarial Learning Based Angiography Reconstruction for Ultra-Low-Dose Contrast Medium CT
    Zhang, Weiwei
    Zhou, Zhen
    Gao, Zhifan
    Yang, Guang
    Xu, Lei
    Wu, Weiwen
    Zhang, Heye
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2023, 27 (01) : 409 - 420