Intraarterial CT Angiography Using Ultra Low Volume of Iodine Contrast - Own Experiences

被引:3
|
作者
Garcarek, Jerzy [1 ]
Kurcz, Jacek [1 ]
Guzinski, Maciej [1 ]
Banasik, Miroslaw [2 ]
Mis, Marcin [1 ]
Golebiowski, Tomasz [2 ]
机构
[1] Wroclaw Med Univ, Dept Gen Radiol Intervent Radiol Ang Neuroradiol, Wroclaw, Poland
[2] Wroclaw Med Univ, Dept Nephrol & Transplantat Med, Wroclaw, Poland
关键词
Angiography; Digital Subtraction; Contrast Media; Gastrointestinal Hemorrhage; Infusions; Intra-Arterial; Kidney Transplantation; Multidetector Computed Tomography;
D O I
10.12659/PJR.894050
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: High volume of intravenous contrast in CT-angiography may result in contrast-induced nephropathy. Intraarterial ultra-low volume of contrast medium results in its satisfactory blood concentration with potentially good image quality. The first main purpose was to assess the influence of the method on function of transplanted kidney in patients with impaired graft function. The second main purpose of the study was to evaluate the usefulness of this method for detection of gastrointestinal and head-and-neck haemorrhages. Material/Methods: Between 2010 and 2013 intraarterial CT-angiography was performed in 56 patients, including 28 with chronic kidney disease (CKD). There were three main subgroups: 18 patients after kidney transplantation, 10 patients with gastrointestinal hemorrhage, 8 patients with head-and-neck hemorrhage. Contralateral or ipsilateral inguinal arterial approach was performed. The 4-French vascular sheaths and 4F-catheters were introduced under fluoroscopy. Intraarterial CT was performed using 64-slice scanner. The scanning protocol was as follows: slice thickness 0.625 mm, pitch 1.3, gantry rotation 0.6 sec., scanning delay 1-2 sec. The extent of the study was established on the basis of scout image. In patients with CKD 6-8 mL of Iodixanol (320 mg/mL) diluted with saline to 18-24 mL was administered at a speed of 4-5 mL/s. Results: Vasculature was properly visualized in all patients. In patients with impaired renal function creatinine/eGFR levels remained stable in all but one case. Traditional arteriography failed and CT-angiography demonstrated the site of bleeding in 3 of 10 patients with symptoms of gastrointestinal bleeding (30%). In 8 patients with head-and-neck bleeding CT-angiography did not prove beneficial when compared to traditional arteriography. Conclusions: 1. Ultra-low contrast intraarterial CT-angiography does not deteriorate the function of transplanted kidneys in patients with impaired graft function. 2. 3D reconstructions allow for excellent visualization of vascular anatomy of renal transplants. 3. Intraarterial CT-angiography is useful for detection of the bleeding site.
引用
收藏
页码:344 / 349
页数:6
相关论文
共 50 条
  • [1] CONTRAST MATERIALS WITH LOW IODINE CONCENTRATION AND INTRAARTERIAL DIGITAL SUBTRACTION ANGIOGRAPHY
    CARELLA, A
    RESTA, M
    DAPRILE, P
    JOURNAL OF NEURORADIOLOGY, 1990, 17 (03) : 201 - 211
  • [2] Feasibility of low contrast media volume in CT angiography of the aorta
    Seehofnerova, Anna
    Kok, Madeleine
    Mihl, Casper
    Douwes, Dave
    Sailer, Anni
    Nijssen, Estelle
    Michiel, J. W. de Haan
    Wildberger, Joachim E.
    Das, Marco
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2015, 2 : 58 - 65
  • [3] Carotid and cerebral CT angiography using low volume of iodinated contrast material and low tube voltage
    Kayan, M.
    Demirtas, H.
    Turker, Y.
    Kayan, F.
    Cetinkaya, G.
    Kara, M.
    Celik, A. Orhan
    Umul, A.
    Yilmaz, O.
    Aktas, A. Recep
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2016, 97 (11) : 1173 - 1179
  • [4] Low tube voltage and low contrast material volume cerebral CT angiography
    Song Luo
    Long Jiang Zhang
    Felix G. Meinel
    Chang Sheng Zhou
    Li Qi
    Andrew D. McQuiston
    U. Joseph Schoepf
    Guang Ming Lu
    European Radiology, 2014, 24 : 1677 - 1685
  • [5] Low tube voltage and low contrast material volume cerebral CT angiography
    Luo, Song
    Zhang, Long Jiang
    Meinel, Felix G.
    Zhou, Chang Sheng
    Qi, Li
    McQuiston, Andrew D.
    Schoepf, U. Joseph
    Lu, Guang Ming
    EUROPEAN RADIOLOGY, 2014, 24 (07) : 1677 - 1685
  • [6] CT Angiography in the Lower Extremity Peripheral Artery Disease Feasibility of an Ultra-Low Volume Contrast Media Protocol
    Barbora Horehledova
    Casper Mihl
    Gianluca Milanese
    Rutger Brans
    Nienke G. Eijsvoogel
    Babs M. F. Hendriks
    Joachim E. Wildberger
    Marco Das
    CardioVascular and Interventional Radiology, 2018, 41 : 1751 - 1764
  • [7] Feasibility of low contrast volume and low injection flow rate in CT pulmonary angiography
    Lee, Wan Chin
    Poon, Jun Kai
    Siah, Jacqueline Jin Hui
    Chong, Mei Choo
    Lai, Christopher
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2025, 56 (01)
  • [8] CT Angiography in the Lower Extremity Peripheral Artery Disease Feasibility of an Ultra-Low Volume Contrast Media Protocol
    Horehledova, Barbora
    Mihl, Casper
    Milanese, Gianluca
    Brans, Rutger
    Eijsvoogel, Nienke G.
    Hendriks, Babs M. F.
    Wildberger, Joachim E.
    Das, Marco
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2018, 41 (11) : 1751 - 1764
  • [9] Intra-arterial Ultra Low Iodine CT Angiography of Renal Transplant Arteries
    Christian E. Althoff
    Rolf W. Günther
    Bernd Hamm
    Matthias Rief
    CardioVascular and Interventional Radiology, 2014, 37 : 1062 - 1067
  • [10] Optimizing low contrast volume thoracic CT angiography: From the basics to the advanced
    Kaproth-Joslin, Katherine
    Hobbs, Susan
    Rajiah, Prabhakar
    Chaturvedi, Apeksha
    Chaturvedi, Abhishek
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2022, 12