Feasibility of low contrast volume and low injection flow rate in CT pulmonary angiography

被引:0
|
作者
Lee, Wan Chin [1 ]
Poon, Jun Kai [2 ]
Siah, Jacqueline Jin Hui [2 ]
Chong, Mei Choo [1 ]
Lai, Christopher [2 ]
机构
[1] Changi Gen Hosp, Radiog, Singapore, Singapore
[2] Singapore Inst Technol, Hlth & Social Sci Cluster, Singapore, Singapore
关键词
Computed tomography pulmonary angiography; Radiation dose; Contrast; Injection rate; COMPUTED-TOMOGRAPHY; EMBOLISM; OPTIMIZATION;
D O I
10.1016/j.jmir.2023.11.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Computed Tomography Pulmonary Angiography (CTPA) is currently the gold standard for diagnosing Pulmonary Embolism (PE), with a high flowrate ( > 4.5ml/s) for contrast media (CM) administration recommended for sufficient pulmonary artery opacification. However, this may not be achievable for patients with challenging IV access. Aim: To determine if a low volume CM, low flowrate (LVLF) CTPA protocol produces images of similar image quality compared to a standard protocol in two aspects, in terms of peak arterial enhancement through the quantitative measurement of Hounsfield unit (HU) and based on subjective overall image quality. Methods: Retrospective collection of 151 patients who underwent CTPA via 320 slice multi-detector CT due to clinical suspicion of PE. 80 patients underwent the standard protocol, with a fixed flowrate of 4.5ml/s and 50ml of CM, while 71 patients underwent the LVLF protocol with up to a 37% and 30% reduction in flowrate and CM administered, respectively. Two independent radiographers measured the attenuation of multiple pulmonary arteries in HU, with >= 200HU being considered diagnostic. Overall image quality was also reviewed using a 5-point close-ended questionnaire by two independent radiologists. Results: There was no significant difference in terms of attenuation measured in HU for the seven regions of interest (main pulmonary trunk, right and left pulmonary arteries, right and left lobar arteries, and right and left subsegmental arteries (RSA and LSA)) between the LVLF and standard CTPA protocol. Similarly, there were no significant differences in the overall image quality score obtained from standard and LVLF protocols reported by both radiologists. Conclusion: The LVLF protocol can achieve similar enhancement and subjective image quality as the standard CTPA protocol, potentially allowing for further optimisation in the CM dosage.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Feasibility of low contrast media volume in CT angiography of the aorta
    Seehofnerova, Anna
    Kok, Madeleine
    Mihl, Casper
    Douwes, Dave
    Sailer, Anni
    Nijssen, Estelle
    Michiel, J. W. de Haan
    Wildberger, Joachim E.
    Das, Marco
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2015, 2 : 58 - 65
  • [2] Aortic dual-energy CT angiography with low contrast medium injection rate
    Liu, Jie
    Lv, Pei-Jie
    Wu, Runze
    Zhang, Yong-Gao
    Hu, Li-Li
    Hou, Ping
    Gao, Jian-Bo
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2014, 22 (05) : 689 - 696
  • [3] Low tube voltage and low contrast material volume cerebral CT angiography
    Song Luo
    Long Jiang Zhang
    Felix G. Meinel
    Chang Sheng Zhou
    Li Qi
    Andrew D. McQuiston
    U. Joseph Schoepf
    Guang Ming Lu
    European Radiology, 2014, 24 : 1677 - 1685
  • [4] Low tube voltage and low contrast material volume cerebral CT angiography
    Luo, Song
    Zhang, Long Jiang
    Meinel, Felix G.
    Zhou, Chang Sheng
    Qi, Li
    McQuiston, Andrew D.
    Schoepf, U. Joseph
    Lu, Guang Ming
    EUROPEAN RADIOLOGY, 2014, 24 (07) : 1677 - 1685
  • [5] Clinical value and feasibility of CT pulmonary angiography with personalized injection of contrast agent in pulmonary embolism
    Tang, Zhiming
    Fan, Kun
    Qiu, Lanyu
    Chen, Likang
    Qian, Qilin
    Zhang, Ting
    Wang, Yi
    Han, Menglong
    Deng, Chengjian
    He, Weihong
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2022, 14 (09): : 6774 - 6781
  • [6] Feasibility of Computed Tomography Pulmonary Angiography with Low Flow Rates
    Gossner, J.
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2012, 2
  • [7] Feasibility Assessment of Low Iodine Flow Rate Imaging in Abdominal Contrast-enhanced CT
    Li, Ye
    Zhang, Hui-mao
    Li, Hong-yan
    PROCEEDINGS OF THE 2016 INTERNATIONAL CONFERENCE ON BIOMEDICAL AND BIOLOGICAL ENGINEERING, 2016, : 478 - 481
  • [8] High-Pitch Coronary CT Angiography at 70 kVp Adopting a Protocol of Low Injection Speed and Low Volume of Contrast Medium
    Feng, Ruiqi
    Tong, Jiajie
    Liu, Xiaofei
    Zhao, Yu
    Zhang, Liang
    KOREAN JOURNAL OF RADIOLOGY, 2017, 18 (05) : 763 - 772
  • [9] Scan time adapted contrast agent injection protocols with low volume for low- tube voltage CT angiography: An in vitro study
    Benz, Matthias R.
    Szucs-Farkas, Zsolt
    Froehlich, Johannes M.
    Stadelmann, Geraldine
    Bongartz, Georg
    Bouwman, Luc
    Schindera, Sebastian T.
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 93 : 65 - 69
  • [10] Optimizing low contrast volume thoracic CT angiography: From the basics to the advanced
    Kaproth-Joslin, Katherine
    Hobbs, Susan
    Rajiah, Prabhakar
    Chaturvedi, Apeksha
    Chaturvedi, Abhishek
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2022, 12