Feasibility of low contrast volume and low injection flow rate in CT pulmonary angiography

被引:0
|
作者
Lee, Wan Chin [1 ]
Poon, Jun Kai [2 ]
Siah, Jacqueline Jin Hui [2 ]
Chong, Mei Choo [1 ]
Lai, Christopher [2 ]
机构
[1] Changi Gen Hosp, Radiog, Singapore, Singapore
[2] Singapore Inst Technol, Hlth & Social Sci Cluster, Singapore, Singapore
关键词
Computed tomography pulmonary angiography; Radiation dose; Contrast; Injection rate; COMPUTED-TOMOGRAPHY; EMBOLISM; OPTIMIZATION;
D O I
10.1016/j.jmir.2023.11.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Computed Tomography Pulmonary Angiography (CTPA) is currently the gold standard for diagnosing Pulmonary Embolism (PE), with a high flowrate ( > 4.5ml/s) for contrast media (CM) administration recommended for sufficient pulmonary artery opacification. However, this may not be achievable for patients with challenging IV access. Aim: To determine if a low volume CM, low flowrate (LVLF) CTPA protocol produces images of similar image quality compared to a standard protocol in two aspects, in terms of peak arterial enhancement through the quantitative measurement of Hounsfield unit (HU) and based on subjective overall image quality. Methods: Retrospective collection of 151 patients who underwent CTPA via 320 slice multi-detector CT due to clinical suspicion of PE. 80 patients underwent the standard protocol, with a fixed flowrate of 4.5ml/s and 50ml of CM, while 71 patients underwent the LVLF protocol with up to a 37% and 30% reduction in flowrate and CM administered, respectively. Two independent radiographers measured the attenuation of multiple pulmonary arteries in HU, with >= 200HU being considered diagnostic. Overall image quality was also reviewed using a 5-point close-ended questionnaire by two independent radiologists. Results: There was no significant difference in terms of attenuation measured in HU for the seven regions of interest (main pulmonary trunk, right and left pulmonary arteries, right and left lobar arteries, and right and left subsegmental arteries (RSA and LSA)) between the LVLF and standard CTPA protocol. Similarly, there were no significant differences in the overall image quality score obtained from standard and LVLF protocols reported by both radiologists. Conclusion: The LVLF protocol can achieve similar enhancement and subjective image quality as the standard CTPA protocol, potentially allowing for further optimisation in the CM dosage.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Investigating the Use and Optimization of Low Dose kV and Contrast Media in CT Pulmonary Angiography Examination
    Kara, Mustafa
    Kayan, Mustafa
    Cetinkaya, Gursel
    Turkoglu, Sefa
    Kayan, Fatma
    IRANIAN JOURNAL OF RADIOLOGY, 2018, 15 (03)
  • [42] Validation of renal perfusion with multidetector CT scanner and low rate contrast medium injection
    Lemoine, S.
    Papillard, M.
    Belloi, A.
    Rognant, N.
    Fouque, D.
    Laville, M.
    Rouviere, O.
    Juillard, L.
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2011, 25 : 4 - 4
  • [43] Low-dose CT pulmonary angiography on a 15-year-old CT scanner: a feasibility study
    Kaup, Moritz
    Gruber-Rouh, Tatjana
    Scholtz, Jan E.
    Albrecht, Moritz H.
    Bucher, Andreas
    Frellesen, Claudia
    Vogl, Thomas J.
    Beeres, Martin
    ACTA RADIOLOGICA OPEN, 2016, 5 (12):
  • [44] Feasibility of spectral imaging with low-concentration contrast medium in abdominal CT angiography of obese patients
    Liu, Yijun
    Liu, Ailian
    Liu, Lei
    Tian, Shifeng
    Liu, Jinghong
    Pu, Renwang
    Fang, Xin
    Liu, Xiaofeng
    Yuan, Gang
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2016, 70 (9B) : B37 - B43
  • [45] Low rate of contrast-induced Nephropathy after CT perfusion and CT angiography in acute stroke patients
    Dittrich, R.
    Akdeniz, S.
    Kloska, S. P.
    Fischer, T.
    Ritter, M. A.
    Seidensticker, P.
    Heindel, W.
    Ringelstein, E. B.
    Nabavi, D. G.
    JOURNAL OF NEUROLOGY, 2007, 254 (11) : 1491 - 1497
  • [46] Low rate of contrast-induced Nephropathy after CT perfusion and CT angiography in acute stroke patients
    R. Dittrich
    S. Akdeniz
    S. P. Kloska
    T. Fischer
    M. A. Ritter
    P. Seidensticker
    W. Heindel
    E. B. Ringelstein
    D. G. Nabavi
    Journal of Neurology, 2007, 254 : 1491 - 1497
  • [47] Author Correction: Use of pulmonary CT angiography with low tube voltage and low-iodine-concentration contrast agent to diagnose pulmonary embolism
    Xuemei Hu
    Liya Ma
    Jinhua Zhang
    Zhen Li
    Yaqi Shen
    Daoyu Hu
    Scientific Reports, 8
  • [48] CT-angiography protocol with low dose radiation and low volume contrast medium for non-cardiac chest pain
    Cakmakci, Emin
    Ozkurt, Huseyin
    Tokgoz, Safiye
    Karabay, Esra
    Ucan, Berna
    Akdogan, Melek Pala
    Basak, Muzaffer
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2014, 4 (05) : 307 - 312
  • [49] Individually Optimized Contrast Injection in CT Angiography for the Diagnosis of Pulmonary Thromboembolic Disease
    Xue, M.
    Zhang, H.
    Kligerman, S.
    D'Souza, W.
    Klahr, P.
    Lu, W.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [50] A Vessel Segmentation Method for Low Contrast CT Angiography Image
    Zhu, Rong
    Mao, Yun
    Guo, Ying
    2016 14TH ANNUAL CONFERENCE ON PRIVACY, SECURITY AND TRUST (PST), 2016,