Aortic dual-energy CT angiography with low contrast medium injection rate

被引:12
|
作者
Liu, Jie [1 ]
Lv, Pei-Jie [1 ]
Wu, Runze [1 ]
Zhang, Yong-Gao [1 ]
Hu, Li-Li [1 ]
Hou, Ping [1 ]
Gao, Jian-Bo [1 ]
机构
[1] Zhengzhou Univ, Hosp 1, Dept Radiol, Zhengzhou 450052, Henan, Peoples R China
关键词
Dual-energy CT; contrast medium; aortic angiography; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; IMAGE QUALITY; ABDOMINAL CT; BONE REMOVAL; ENHANCEMENT; IODINE;
D O I
10.3233/XST-140454
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The contrast medium (CM) induced nephropathy required new CT imaging protocol. This study evaluated the feasibility of low contrast medium (CM) volume and injection flow using aortic dual-energy CT (DECT) angiography with non-linear blending technique. Sixty patients were randomly assigned to two groups: control group (n = 30), single-energy CT 70 ml CM at injection rate of 5 ml/s; study group (n = 30), DECT mode, 0.5 ml per kg of patient weight CM at injection rate = (weight x 0.5 ml/kg)/(4 + scan time). Non-linear blending technique was used for dual-energy images. Mean attention, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of aorta were compared. The level of visible renal artery branches was scored. There was no significant difference between the two groups in the mean aortic attention, SNR and CNR (all P > 0.05). Significant difference was showed in CM injection rate (p < 0.001) and volume (P < 0.001). The renal artery score had no statistically significant difference (P = 0.771). Compared conventional scan and CM injection protocol, DECT with non-linear blending technique maintained the image quality of aortic CT angiography with reduced CM volume and flow rate, which could reduce the risks associated with CM injection.
引用
收藏
页码:689 / 696
页数:8
相关论文
共 50 条
  • [1] Utility of dual-energy spectral CT and low-iodine contrast medium in DIEP angiography
    Gao, Zhipeng
    Meng, Donghua
    Lu, Hong
    Yao, Bingyu
    Huang, Ning
    Ye, Zhaoxiang
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2016, 70 (9B) : B64 - B71
  • [2] Optimal Monochromatic Energy Levels in Dual-Energy Spectral CT Pulmonary Angiography with Low Contrast Medium Dosage
    Han, Dong
    Shi, Weihua
    Chen, Xiaoxia
    Zhou, Jieli
    Yu, Yong
    Tian, Xin
    Chen, Jing
    Liu, Mengting
    He, Taiping
    IRANIAN JOURNAL OF RADIOLOGY, 2020, 17 (02)
  • [3] Iterative reconstruction in single-source dual-energy CT angiography: feasibility of low and ultra-low volume contrast medium protocols
    Hou, Ping
    Feng, Xiangnan
    Liu, Jie
    Zhou, Yue
    Jiang, Yaojun
    Jiang, Xiaochen
    Gao, Jianbo
    BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1075):
  • [4] Contrast media injection protocol optimization for dual-energy coronary CT angiography: results from a circulation phantom
    De Santis, Domenico
    Caruso, Damiano
    Schoepf, U. Joseph
    Eid, Marwen
    Albrecht, Moritz H.
    Duguay, Taylor M.
    Varga-Szemes, Akos
    Laghi, Andrea
    De Cecco, Carlo N.
    EUROPEAN RADIOLOGY, 2018, 28 (08) : 3473 - 3481
  • [5] Contrast media injection protocol optimization for dual-energy coronary CT angiography: results from a circulation phantom
    Domenico De Santis
    Damiano Caruso
    U. Joseph Schoepf
    Marwen Eid
    Moritz H. Albrecht
    Taylor M. Duguay
    Akos Varga-Szemes
    Andrea Laghi
    Carlo N. De Cecco
    European Radiology, 2018, 28 : 3473 - 3481
  • [6] Reducing contrast medium dose with low photon energy images in renal dual-energy spectral CT angiography and adaptive statistical iterative reconstruction (ASIR)
    Zhang, Xirong
    Chen, Jing
    Yu, Nan
    Ren, Zhanli
    Tian, Qian
    Tian, Xin
    Jia, Yongjun
    He, Taiping
    Guo, Changyi
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1120):
  • [7] Low-Contrast Agent Dose Dual-Energy CT Monochromatic Imaging in Pulmonary Angiography Versus Routine CT
    Dong, Jian
    Wang, Xiaoying
    Jiang, Xuexiang
    Gao, Li
    Li, Feiyu
    Qiu, Jianxing
    Xu, Yufeng
    Wang, He
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (04) : 618 - 625
  • [8] Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography
    Fleischmann, D
    Rubin, GD
    Bankier, AA
    Hittmair, K
    RADIOLOGY, 2000, 214 (02) : 363 - 371
  • [9] Advanced virtual monoenergetic images: improving the contrast of dual-energy CT pulmonary angiography
    Meier, A.
    Wurnig, M.
    Desbiolles, L.
    Leschka, S.
    Frauenfelder, T.
    Alkadhi, H.
    CLINICAL RADIOLOGY, 2015, 70 (11) : 1244 - 1251
  • [10] The potential of iodinated contrast reduction in dual-energy CT thoracic angiography; an evaluation of image quality
    Johansen, C. B.
    Martinsen, A. C. T.
    Enden, T. R.
    Svanteson, M.
    RADIOGRAPHY, 2022, 28 (01) : 2 - 7