The potential of iodinated contrast reduction in dual-energy CT thoracic angiography; an evaluation of image quality

被引:14
|
作者
Johansen, C. B. [1 ,2 ]
Martinsen, A. C. T. [2 ,3 ]
Enden, T. R. [1 ]
Svanteson, M. [1 ,4 ]
机构
[1] Oslo Univ Hosp, Dept Radiol & Nucl Med, Oslo, Norway
[2] Oslo Metropolitan Univ, Fac Hlth Sci, Oslo, Norway
[3] Sunnaas Rehabil Hosp, Alvaern, Norway
[4] Oslo Univ Hosp, Dept Diagnost Phys, ImTECH, Oslo, Norway
关键词
Computer tomography; Contrast media; Spectral imaging; Iodine; Monoenergetic images; TO-NOISE RATIO; COMPUTED-TOMOGRAPHY; RESOLUTION; PHANTOM;
D O I
10.1016/j.radi.2021.07.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: The purpose of this study was to compare a dual energy CT (DECT) protocol with 50% reduction of iodinated contrast to a single energy CT (SECT) protocol using standard contrast dose in imaging of the thoracic aorta. Methods: DECT with a 50% reduction in iodinated contrast was compared with SECT. For DECT, mono-energetic images at 50, 55, 60, 65, 68, 70, and 74 keV were reconstructed with adaptive statistical iterative reconstruction (ASiR-V) of 50% and 80%. Objective image quality parameters included intravascular attenuation (HU), image noise (SD), contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR). Two independent radiologists subjectively assessed the image quality for the 55 and 68 keV DECT reconstructions and SECT on a five-point Likert scale. Results: Across 14 patients, the intravascular attenuation at 50-55 keV was comparable to SECT (p > 0.05). The CNRs were significantly lower for DECT with ASIR-V 50% compared to SECT for all keV-values (p < 0.05 for all). For ASIR-V 80%, CNR was comparable to SECT at energies below 60 keV (p > 0.05). The subjective image quality was comparable between DECT and SECT independent of keV level. Conclusion: This study indicates that a 50% reduction in iodinated contrast may result in adequate image quality using DECT with monoenergetic reconstructions at lower energy levels for the imaging of the thoracic aorta. The best image quality was obtained for ASiR-V 80% image reconstructions at 55 keV. Implications of practice: Dual energy CT with a reduction in iodinated contrast may result in adequate image quality in imaging of the thoracic aorta. However, increased radiation dose may limit the use to patients in which a reduction in fluid and iodinated contrast volume may outweigh this risk. (C) 2021 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:2 / 7
页数:6
相关论文
共 50 条
  • [1] Impact of iodinated contrast media concentration on image quality for dual-energy CT and single-energy CT with low tube voltage settings
    Sookpeng, Supawitoo
    Martin, Colin J.
    ACTA RADIOLOGICA, 2023, 64 (03) : 1047 - 1055
  • [2] Evaluation of Dual-Energy CT for Differentiating Intracerebral Hemorrhage from Iodinated Contrast Material Staining
    Gupta, Rajiv
    Phan, Catherine M.
    Leidecker, Christianne
    Brady, Thomas J.
    Hirsch, Joshua A.
    Nogueira, Raul G.
    Yoo, Albert J.
    RADIOLOGY, 2010, 257 (01) : 205 - 211
  • [3] Dual-energy CT enables dose calculation on scans with iodinated contrast agent
    Moehler, C.
    Wohlfahrt, P.
    Nicolay, N. H.
    Richter, C.
    Greilich, S.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1147 - S1148
  • [4] Evaluation of image quality and radiation dose of abdominal dual-energy CT
    Schmidt, David
    Soderberg, Marcus
    Nilsson, Mats
    Lindvall, Hakan
    Christoffersen, Christina
    Leander, Peter
    ACTA RADIOLOGICA, 2018, 59 (07) : 845 - 852
  • [5] Dose Savings and Image Quality in Dual-Energy Non-Contrast CT Scans
    Anthony, G.
    Liang, Y.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [6] Neuroimaging Highlight Dual-Energy CT Differentiation of Iodinated Contrast Staining versus Hemorrhage
    Alves, Timothy
    Srinivasan, Ashok
    CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES, 2014, 41 (05) : 648 - 649
  • [7] Image quality improvement in head and neck angiography based on dual-energy CT and deep learning
    He Zhang
    Lulu Zhang
    Juan Long
    He Zhang
    Xiaonan Sun
    Shuai Zhang
    Aiyun Sun
    Shenman Qiu
    Yankai Meng
    Tao Ding
    Chunfeng Hu
    Kai Xu
    BMC Medical Imaging, 25 (1)
  • [8] Aortic dual-energy CT angiography with low contrast medium injection rate
    Liu, Jie
    Lv, Pei-Jie
    Wu, Runze
    Zhang, Yong-Gao
    Hu, Li-Li
    Hou, Ping
    Gao, Jian-Bo
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2014, 22 (05) : 689 - 696
  • [9] Deep learning image reconstruction for improving image quality of contrast-enhanced dual-energy CT in abdomen
    Sato, Mineka
    Ichikawa, Yasutaka
    Domae, Kensuke
    Yoshikawa, Kazuya
    Kanii, Yoshinori
    Yamazaki, Akio
    Nagasawa, Naoki
    Nagata, Motonori
    Ishida, Masaki
    Sakuma, Hajime
    EUROPEAN RADIOLOGY, 2022, 32 (08) : 5499 - 5507
  • [10] Deep learning image reconstruction for improving image quality of contrast-enhanced dual-energy CT in abdomen
    Mineka Sato
    Yasutaka Ichikawa
    Kensuke Domae
    Kazuya Yoshikawa
    Yoshinori Kanii
    Akio Yamazaki
    Naoki Nagasawa
    Motonori Nagata
    Masaki Ishida
    Hajime Sakuma
    European Radiology, 2022, 32 : 5499 - 5507