Aortic dual-energy CT angiography with low contrast medium injection rate

被引:12
|
作者
Liu, Jie [1 ]
Lv, Pei-Jie [1 ]
Wu, Runze [1 ]
Zhang, Yong-Gao [1 ]
Hu, Li-Li [1 ]
Hou, Ping [1 ]
Gao, Jian-Bo [1 ]
机构
[1] Zhengzhou Univ, Hosp 1, Dept Radiol, Zhengzhou 450052, Henan, Peoples R China
关键词
Dual-energy CT; contrast medium; aortic angiography; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; IMAGE QUALITY; ABDOMINAL CT; BONE REMOVAL; ENHANCEMENT; IODINE;
D O I
10.3233/XST-140454
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The contrast medium (CM) induced nephropathy required new CT imaging protocol. This study evaluated the feasibility of low contrast medium (CM) volume and injection flow using aortic dual-energy CT (DECT) angiography with non-linear blending technique. Sixty patients were randomly assigned to two groups: control group (n = 30), single-energy CT 70 ml CM at injection rate of 5 ml/s; study group (n = 30), DECT mode, 0.5 ml per kg of patient weight CM at injection rate = (weight x 0.5 ml/kg)/(4 + scan time). Non-linear blending technique was used for dual-energy images. Mean attention, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of aorta were compared. The level of visible renal artery branches was scored. There was no significant difference between the two groups in the mean aortic attention, SNR and CNR (all P > 0.05). Significant difference was showed in CM injection rate (p < 0.001) and volume (P < 0.001). The renal artery score had no statistically significant difference (P = 0.771). Compared conventional scan and CM injection protocol, DECT with non-linear blending technique maintained the image quality of aortic CT angiography with reduced CM volume and flow rate, which could reduce the risks associated with CM injection.
引用
收藏
页码:689 / 696
页数:8
相关论文
共 50 条
  • [41] Application of dual-energy CT with prospective ECG-gating in cardiac CT angiography for children: Radiation and contrast agent dose
    Xie, Mingye
    Wang, Haoru
    Tang, Shilong
    Chen, Mingjing
    Li, Ting
    He, Ling
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 170
  • [42] Low-Dose CT Angiography: Which Contrast Medium?
    Iezzi, Roberto
    Bonomo, Lorenzo
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (04) : W660 - W660
  • [43] Assessment of Calcified Carotid Plaque Volume: Comparison of Contrast-Enhanced Dual-Energy CT Angiography and Native Single-Energy CT
    Watanabe, Yoshiyuki
    Nakazawa, Tetsuro
    Higashi, Masahiro
    Itoh, Toshihide
    Naito, Hiroaki
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) : W796 - W799
  • [44] Bowel Peristalsis Artifact on Dual-Energy CT: In Vitro Study on the Influence of Different Dual-Energy CT Platforms and Enteric Contrast Agents
    Obmann, Markus M.
    Sun, Yuxin
    An, Chansik
    Ohliger, Michael A.
    Wang, Zhen J.
    Yeh, Benjamin M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (02) : 290 - 299
  • [45] Value of dual-energy CT angiography in patients with treated intracranial aneurysms
    Iulia Mocanu
    Morgane Van Wettere
    Julie Absil
    Michaël Bruneau
    Boris Lubicz
    Niloufar Sadeghi
    Neuroradiology, 2018, 60 : 1287 - 1295
  • [46] Grading of Carotid Artery Stenosis in the Presence of Extensive Calcifications: Dual-Energy CT Angiography in Comparison with Contrast-Enhanced MR Angiography
    Korn, A.
    Bender, B.
    Brodoefel, H.
    Hauser, T. -K.
    Danz, S.
    Ernemann, U.
    Thomas, C.
    CLINICAL NEURORADIOLOGY, 2015, 25 (01) : 33 - 40
  • [47] Dual-energy CT angiography for the diagnosis of intracranial dural arteriovenous fistula
    Guo, Yuanxing
    Ou, Shan-Xing
    Qian, Min
    Zeng, Xiaotao
    Li, Bin
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (05): : 7802 - 7808
  • [48] Value of dual-energy CT angiography in patients with treated intracranial aneurysms
    Mocanu, Iulia
    Van Wettere, Morgane
    Absil, Julie
    Bruneau, Michael
    Lubicz, Boris
    Sadeghi, Niloufar
    NEURORADIOLOGY, 2018, 60 (12) : 1287 - 1295
  • [49] Grading of Carotid Artery Stenosis in the Presence of Extensive Calcifications: Dual-Energy CT Angiography in Comparison with Contrast-Enhanced MR Angiography
    A. Korn
    B. Bender
    H. Brodoefel
    T.-K. Hauser
    S. Danz
    U. Ernemann
    C. Thomas
    Clinical Neuroradiology, 2015, 25 : 33 - 40
  • [50] Dual-Energy Heart CT: Beyond Better Angiography-Review
    Tarkowski, Piotr
    Czekajska-Chehab, Elzbieta
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (21)