A Homogeneous Water-Equivalent Anthropomorphic Phantom for Dosimetric Verification of Radiotherapy Plans

被引:11
|
作者
Arjunan, Manikandan [1 ,2 ]
Sekaran, Sureka Chandra [1 ]
Sarkar, Biplab [3 ]
Manikandan, Sujatha [4 ]
机构
[1] Bharathiar Univ, Dept Med Phys, Coimbatore 641046, Tamil Nadu, India
[2] Nagarjuna Hosp, Dept Radiat Oncol, Vijayawada, Andhra Pradesh, India
[3] Fortis Hosp, Dept Radiat Oncol, New Delhi, India
[4] Govt Gen Hosp, Dept Radiotherapy, Guntur, Andhra Pradesh, India
关键词
Alent radiological depth; tissue equivalent phantom; water equivalent depth (WED) phantom;
D O I
10.4103/jmp.JMP_123_17
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Water is treated as radiological equivalent to human tissue. While this seems justified, there is neither mathematical proof nor sufficient experimental evidence that a water phantom can be treated as equivalent to human tissue. The aim of this work is to simulate and validate a water phantom that is tissue equivalent in terms of the dosimetric characteristics of both water and human tissue Dynamic, intensity-modulated radiotherapy plans for two head and neck, one brain, one pelvis, and three lung/mediastinum cases were chosen for this study. Using a treatment planning system (TPS) (Eclipse, Varian Medical System, Polo Alto, CA, USA) and Anisotropic Analytic Algorithm in a grid resolution of 5 mm x 5 mm, a patient-equivalent water phantom was calculated from all rays in the isocentric plane as an array of water equivalent depths (d(WE)). These rays were plotted versus isocentric separation and ray-tracing direction. Planar doses were compared between the isocentric plane in the patient computed tomography and the water equivalent phantom using gamma criteria of 2%-2 mm and 3%-3 mm. Except in one lung case, >95% gamma agreement was seen when using 3%-3 mm and >90% pass rate was seen when using 2%-2 mm. For head and neck cases, gamma-fail was restricted to the periphery. For mediastinum cases, gamma-fail was restricted to the lungs. This study demonstrates that a heterogeneous patient can be converted to a water phantom with comparable dosimetric characteristics and disagreements restricted to the lung area for both modulated and open beams. Potential sources of error include the d(WE) calculation and TPS dose computation.
引用
收藏
页码:100 / 105
页数:6
相关论文
共 50 条
  • [31] Effects of Interfractional Anatomical Changes on Water-Equivalent Pathlength in Charged-Particle Radiotherapy of Lung Cancer
    Mori, Shinichiro
    Lu, Hsiao-Ming
    Wolfgang, John A.
    Choi, Noah C.
    Chen, George T. Y.
    JOURNAL OF RADIATION RESEARCH, 2009, 50 (06) : 513 - 519
  • [32] Water-equivalent pathlength reproducibility due to respiratory pattern variation in charged-particle pancreatic radiotherapy
    Kumagai M.
    Mori S.
    Hara R.
    Asakura H.
    Kishimoto R.
    Kato H.
    Yamada S.
    Kandatsu S.
    Radiological Physics and Technology, 2009, 2 (1) : 112 - 118
  • [33] Verification of water-equivalent model for calculation of multiple scattering effects in simplified Monte Carlo dose calculation
    Kohno, R
    Takada, Y
    Sakae, T
    Terunuma, T
    Matsumoto, K
    Nohtomi, A
    Matsuda, H
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2003, 42 (6A): : 3728 - 3729
  • [34] Dosimetric verification of stereotactic treatment plans using 3D-printed phantom and GafchromicEBT3
    Kruszyna, M.
    Skrobala, A.
    Pawalowski, B.
    Szweda, H.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S966 - S966
  • [35] Optical observation of energy loss distribution and practical range of positrons from a 18F water solution in a water-equivalent phantom
    Hasegawa, Tomoyuki
    Yoshida, Eiji
    Shibuya, Kengo
    Murayama, Hideo
    MEDICAL PHYSICS, 2009, 36 (02) : 402 - 410
  • [36] A novel water-equivalent electronic portal imaging device for radiotherapy with improved detective quantum efficiency: Proof of concept
    Blake, Samuel J.
    Cheng, Zhangkai
    Atakaramians, Shaghik
    Meikle, Steven
    Lu, Minghui
    Vial, Philip
    Kuncic, Zdenka
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [37] Acuros(R)dose verification of ultrasmall lung lesions with EBT-XD film in a homogeneous and heterogeneous anthropomorphic phantom setup
    Ollers, Michel C.
    Swinnen, Ans C. C.
    Verhaegen, Frank
    MEDICAL PHYSICS, 2020, 47 (11) : 5829 - 5837
  • [38] A Novel Anthropomorphic Phantom Composed of Tissue-Equivalent Materials for Use in Experimental Radiotherapy: Design, Dosimetry and Biological Pilot Study
    Breslin, Thomas
    Paino, Jason
    Wegner, Marie
    Engels, Elette
    Fiedler, Stefan
    Forrester, Helen
    Rennau, Hannes
    Bustillo, John
    Cameron, Matthew
    Hausermann, Daniel
    Hall, Christopher
    Krause, Dieter
    Hildebrandt, Guido
    Lerch, Michael
    Schueltke, Elisabeth
    BIOMIMETICS, 2023, 8 (02)
  • [39] An in-house step-wedge phantom for the calibration of pixel values in CT localizer radiographs for water-equivalent diameter measurement
    Rif'ah, Sitti M.
    Anam, Choirul
    Sutanto, Heri
    Asiah, Rin H.
    Cholid, Heryani
    Dougherty, Geoff
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2023, 29 (01): : 50 - 57
  • [40] Comparing water equivalent phantom materials using CT scans and conformal prostate treatment plans
    Kirby, M.
    Bridge, P.
    Callender, J.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S915 - S915