SUBSAMPLE VOLUME PROCESSING OF DOPPLER ULTRASOUND SIGNALS

被引:20
|
作者
HOEKS, APG [1 ]
BRANDS, PJ [1 ]
ARTS, TGJ [1 ]
RENEMAN, RS [1 ]
机构
[1] UNIV LIMBURG,CARDIOVASC RES INST MAASTRICHT,DEPT PHYSIOL,6200 MD MAASTRICHT,NETHERLANDS
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 1994年 / 20卷 / 09期
关键词
ACCURACY; PULSED DOPPLER; RF PROCESSING; SIGNAL SIMULATION; SUBSAMPLE VOLUMES; ULTRASOUND; VELOCITY ESTIMATION; VARIANCE;
D O I
10.1016/0301-5629(94)90054-X
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Processing of Doppler signals produced by pulsed Doppler systems is based on the assumption that the phase of the received high frequency ultrasound signals changes linearly with depth. However, the random spatial distribution of scatterers is not in accordance with this basic assumption. Consequently, averaging af the demodulated signal over an observation window, covering a few periods of the received signal, does not improve the estimate for the instantaneous quadrature components of the Doppler signal originating from a given depth. Hence, the accuracy of the Doppler velocity estimate is independent of the length of the observation window employed. However, splitting the observation window in subsample volumes, each with a length of one period at the emission frequency, and combining the Doppler signals of the subsample volumes at the last stage of signal processing, i.e., mean Doppler frequency estimation using the autocorrelation technique, results in a consideration reduction of the variance of the velocity estimate. Using a computer simulation of the signal processing involved, it is demonstrated that with subsample volume processing the variance of the velocity estimate attains the same variance as is expected for the RF cross correlation technique.
引用
收藏
页码:953 / 965
页数:13
相关论文
共 50 条
  • [32] Digital processing of complex modulated ultrasound signals
    Hans, V
    ISMTII'2001: PROCEEDINGS OF THE FIFTH INTERNATIONAL SYMPOSIUM ON MEASUREMENT TECHNOLOGY AND INTELLIGENT INSTRUMENTS, 2001, : 291 - 296
  • [33] Acceleration effects in Doppler ultrasound signals from pulsatile flow
    Bastos, CAC
    Fish, PJ
    Vaz, F
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 238 - 241
  • [34] Spectrum convolution theorem and spectra composition for Doppler ultrasound signals
    Xi'an Jiaotong Univ, Xi'an, China
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 1998, 32 (07): : 15 - 20
  • [35] Grading of ultrasound Doppler signals in synovitis: does it need an update?
    Schmidt, Wolfgang A.
    Schoenau, Verena
    Reiche, Britta E.
    Oberdorfer, Philipp D.
    Ohrndorf, Sarah
    Backhaus, Marina
    RHEUMATOLOGY, 2015, 54 (10) : 1897 - 1903
  • [36] CORRELATION OF DOPPLER ULTRASOUND TUMOR SIGNALS WITH NEOVASCULAR MORPHOLOGIC FEATURES
    TAYLOR, KJW
    RAMOS, I
    CARTER, D
    MORSE, SS
    SNOWER, D
    FORTUNE, K
    RADIOLOGY, 1988, 166 (01) : 57 - 62
  • [37] A SIMULATION OF TRANSIT-TIME EFFECTS IN DOPPLER ULTRASOUND SIGNALS
    JONES, SA
    GIDDENS, DP
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (06): : 607 - 619
  • [38] FRACTAL CONCEPT AND ITS ANALYSIS METHOD FOR DOPPLER ULTRASOUND SIGNALS
    WANG, YY
    WANG, WQ
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (08): : 661 - 666
  • [39] The information content of Doppler ultrasound signals from the fetal heart
    Shakespeare, SA
    Crowe, JA
    Hayes-Gill, BR
    Bhogal, K
    James, DK
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2001, 39 (06) : 619 - 626
  • [40] Spectrum of Doppler ultrasound signals from nonstationary blood flow
    Bastos, CAC
    Fish, PJ
    Vaz, F
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (05) : 1201 - 1217