SUBSAMPLE VOLUME PROCESSING OF DOPPLER ULTRASOUND SIGNALS

被引:20
|
作者
HOEKS, APG [1 ]
BRANDS, PJ [1 ]
ARTS, TGJ [1 ]
RENEMAN, RS [1 ]
机构
[1] UNIV LIMBURG,CARDIOVASC RES INST MAASTRICHT,DEPT PHYSIOL,6200 MD MAASTRICHT,NETHERLANDS
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 1994年 / 20卷 / 09期
关键词
ACCURACY; PULSED DOPPLER; RF PROCESSING; SIGNAL SIMULATION; SUBSAMPLE VOLUMES; ULTRASOUND; VELOCITY ESTIMATION; VARIANCE;
D O I
10.1016/0301-5629(94)90054-X
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Processing of Doppler signals produced by pulsed Doppler systems is based on the assumption that the phase of the received high frequency ultrasound signals changes linearly with depth. However, the random spatial distribution of scatterers is not in accordance with this basic assumption. Consequently, averaging af the demodulated signal over an observation window, covering a few periods of the received signal, does not improve the estimate for the instantaneous quadrature components of the Doppler signal originating from a given depth. Hence, the accuracy of the Doppler velocity estimate is independent of the length of the observation window employed. However, splitting the observation window in subsample volumes, each with a length of one period at the emission frequency, and combining the Doppler signals of the subsample volumes at the last stage of signal processing, i.e., mean Doppler frequency estimation using the autocorrelation technique, results in a consideration reduction of the variance of the velocity estimate. Using a computer simulation of the signal processing involved, it is demonstrated that with subsample volume processing the variance of the velocity estimate attains the same variance as is expected for the RF cross correlation technique.
引用
收藏
页码:953 / 965
页数:13
相关论文
共 50 条
  • [21] COMPUTER-PROCESSING OF CARDIAC DOPPLER SIGNALS
    HERINGA, A
    ALSTERS, J
    HOPMAN, J
    VANDAM, I
    DANIELS, O
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1988, 26 (02) : 147 - 152
  • [22] STFT or CWT for the detection of Doppler ultrasound embolic signals
    Goncalves, Ivo B.
    Leiria, Ana
    Moura, M. M. M.
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2013, 29 (09) : 964 - 976
  • [23] Spectral composition of ultrasound Doppler blood flow signals
    Wen, Yu
    Wan, Mingxi
    Wang, Supin
    Qian, Ming
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 1997, 31 (01): : 69 - 75
  • [24] Analytic approximation of Doppler ultrasound blood flow signals
    Moura, MMM
    Leiria, A
    Ruano, MG
    2005 IEEE International Workshop on Intelligent Signal Processing (WISP), 2005, : 387 - 391
  • [25] DETECTION OF ASYMPTOMATIC CEREBRAL EMBOLIC SIGNALS WITH DOPPLER ULTRASOUND
    MARKUS, HS
    DROSTE, DW
    BROWN, MM
    LANCET, 1994, 343 (8904): : 1011 - 1012
  • [26] MP3 compression of Doppler ultrasound signals
    Poepping, TL
    Gill, J
    Fenster, A
    Holdsworth, DW
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (01): : 65 - 76
  • [27] DIGITAL PROCESSING CHAIN FOR A DOPPLER ULTRASOUND SUBSYSTEM
    HUNT, BF
    LEAVITT, SC
    HEMPSTEAD, DC
    HEWLETT-PACKARD JOURNAL, 1986, 37 (06): : 45 - 48
  • [28] Hilbert transform for processing of laser Doppler vibrometer signals
    Grechikhin, VA
    Rinkevichius, BS
    OPTICS AND LASERS IN ENGINEERING, 1998, 30 (02) : 151 - 161
  • [29] Modelling and processing of laser Doppler reactive hyperaemia signals
    Humeau, A
    Saumet, JL
    L'Huillier, JP
    25TH INTERNATIONAL CONGRESS ON HIGH-SPEED PHOTOGRAPHY AND PHOTONICS, 2003, 4948 : 257 - 262
  • [30] A New Wavelet Transform Method for Processing Doppler Signals
    Serbes, Goerkem
    Aydin, Nizamettin
    BIYOMUT: 2009 14TH NATIONAL BIOMEDICAL ENGINEERING MEETING, 2009, : 120 - +