GLUCOSE POTENTIOMETRIC ELECTRODES BASED ON MEDIATORLESS BIOELECTROCATALYSIS - A NEW APPROACH

被引:23
|
作者
GHINDILIS, AL
KUROCHKIN, IN
机构
[1] Dept. of Biosensors, Research Centre for Molecular Diagnostics, 113149 Moscow
来源
BIOSENSORS & BIOELECTRONICS | 1994年 / 9卷 / 4-5期
关键词
GLUCOSE; GLUCOSE OXIDASE; PEROXIDASE; BIOSENSOR;
D O I
10.1016/0956-5663(94)80035-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A potentiometric method has been developed for analysis of glucose on the basis of glucose oxidase and peroxidase co-immobilized on the surface of an electrode made of composite carbonic material. Catalytic oxidation of glucose results in the formation of hydrogen peroxide. Mediatorless peroxidase catalysis of electroreduction of hydrogen peroxide leads to a shift in the electrode potential. The rate of the increase of the electrode potential is proportional to glucose concentration and calibration curve is linear at 0.025-2.0 mM. Electrodes permit at least 100 measurements without any loss in the activity. Electrodes remain stable for 90 days when stored at 277 K.
引用
收藏
页码:353 / 357
页数:5
相关论文
共 50 条
  • [1] POTENTIOMETRIC ENZYME ELECTRODES BASED ON SUBSTRATE RECYCLING AND MEDIATORLESS BIOELECTROCATALYSIS
    GHINDILIS, AL
    MAKOWER, A
    SCHELLER, FW
    SENSORS AND ACTUATORS B-CHEMICAL, 1995, 28 (02) : 109 - 112
  • [2] Potentiometric biosensors for cholinesterase inhibitor analysis based on mediatorless bioelectrocatalysis
    Ghindilis, AL
    Morzunova, TG
    Barmin, AV
    Kurochkin, IN
    BIOSENSORS & BIOELECTRONICS, 1996, 11 (09): : 873 - 880
  • [3] Potentiometric biosensors for cholinesterase inhibitor analysis based on mediatorless bioelectrocatalysis
    Ghindilis, Andrey L.
    Morzunova, Tatyana G.
    Barmin, Anatoly V.
    Kurochkin, IIya N.
    Biosensors and Bioelectronics, 1996, 11 (09): : 873 - 880
  • [4] Environmental biosensors based on mediatorless bioelectrocatalysis
    Atanasov, P
    Espinosa, M
    Wilkins, E
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1999, 217 : U790 - U790
  • [5] A LACCASE-GLUCOSE DEHYDROGENASE RECYCLING-ENZYME ELECTRODE BASED ON POTENTIOMETRIC MEDIATORLESS ELECTROCATALYTIC DETECTION
    GHINDILIS, AL
    MAKOWER, A
    SCHELLER, FW
    ANALYTICAL METHODS AND INSTRUMENTATION, 1995, 2 (03): : 129 - 132
  • [6] Mediatorless bioelectrocatalysis of dioxygen reduction at indium-doped tin oxide (ITO) and ITO nanoparticulate film electrodes
    Rozniecka, Ewa
    Jonsson-Niedziolka, Martin
    Sobczak, Janusz W.
    Opallo, Marcin
    ELECTROCHIMICA ACTA, 2011, 56 (24) : 8739 - 8745
  • [7] AMPEROMETRIC BIOSENSORS BASED ON BIOCATALYST ELECTRODES. MEDIATED AND MEDIATORLESS ENZYME ELECTRODES
    Ikeda, Tokuji
    Miyaoka, Syuji
    Ozawa, Shyogo
    Matsushita, Fumio
    Kobayashi, Daisuke
    Senda, Mitsugi
    ANALYTICAL SCIENCES, 1991, 7 : 1443 - 1446
  • [8] Potentiometric Biosensing of Glucose by Fullerene-Based Silver Selective Electrodes
    Kumar, Anish
    Patel, Bhargav
    Patel, Gaurang
    Menon, Shobhana K.
    FULLERENES NANOTUBES AND CARBON NANOSTRUCTURES, 2010, 18 (03) : 186 - 197
  • [9] Mediatorless high-power glucose biofuel cells based on compressed carbon nanotube-enzyme electrodes
    Zebda, Abdelkader
    Gondran, Chantal
    Le Goff, Alan
    Holzinger, Michael
    Cinquin, Philippe
    Cosnier, Serge
    NATURE COMMUNICATIONS, 2011, 2
  • [10] Mediatorless high-power glucose biofuel cells based on compressed carbon nanotube-enzyme electrodes
    Abdelkader Zebda
    Chantal Gondran
    Alan Le Goff
    Michael Holzinger
    Philippe Cinquin
    Serge Cosnier
    Nature Communications, 2