Potentiometric Biosensing of Glucose by Fullerene-Based Silver Selective Electrodes

被引:12
|
作者
Kumar, Anish [1 ]
Patel, Bhargav [1 ]
Patel, Gaurang [1 ]
Menon, Shobhana K. [1 ]
机构
[1] Gujarat Univ, Sch Sci, Dept Chem, Ahmadabad 380009, Gujarat, India
关键词
Ag plus - selective electrode; fullerenes; glucose; sensors; silver nanoparticle; CATION-PI INTERACTIONS; PERFORMANCE; IONOPHORES; AG+;
D O I
10.1080/15363831003782890
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A novel methanofullerene containing pyridine pendants has been synthesized and used to fabricate a silver selective electrode. The selectivity coefficient was found to be 6.9 x10-5 and 6.2 x 10-5, respectively, for Cu2+ and Hg2+, while for other cations it was less than 10-5. It has a Nernstian behavior over a wide concentration range of Ag+ ion (5 x 10-7 to 1 x 10-1 mol L-1). The slope and linear range from the calibration graph was found to be 58.8 mV decade-1 and 5.0 x 10-7 to 1.0 x 10-1 mol L-1, respectively. The limit of detection was found to be 1 x 10-7 mol L-1. The fabricated electrodes can be used in a wide pH range (pH 4-7.5) with a response time less than 10 s. The fabricated electrodes were used for bioanalysis of glucose with silver nanoparticle as the potential redox marker. The working linear range for glucose detection was found to be 1 x 10-5 to 1 x 10-3 in phosphate buffer (pH 6.6). Parameters affecting the reaction rate such as pH and the amount of GOx and AgNPs were analyzed. The lower detection limit was 1.0 x 10-6 M. The sensors exhibited very good repeatability with %R.S.D. 6 and high sensor-to-sensor reproducibility. Application in analysis of glucose in real life sample (blood plasma) has also been demonstrated.
引用
收藏
页码:186 / 197
页数:12
相关论文
共 50 条
  • [1] Fullerene-based electrochemical buffer layer for ion-selective electrodes
    Fouskaki, Maria
    Chaniotakis, Nikos
    ANALYST, 2008, 133 (08) : 1072 - 1075
  • [2] CALIXARENE-BASED POTENTIOMETRIC ION-SELECTIVE ELECTRODES FOR SILVER
    OCONNOR, KM
    SVEHLA, G
    HARRIS, SJ
    MCKERVEY, MA
    TALANTA, 1992, 39 (11) : 1549 - 1554
  • [3] POTENTIOMETRIC TITRATION OF SILVER WITH ION-SELECTIVE ELECTRODES
    GEISSLER, M
    ANALYTICA CHIMICA ACTA, 1977, 90 (MAY) : 249 - 252
  • [4] Copper and silver electrodes for the potentiometric and voltammetric determination of glucose and other carbohydrates
    Abdullin, IF
    Budnikov, GK
    Bakanina, YN
    Kukushkina, NN
    JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 53 (10) : 935 - 939
  • [5] Nanoparticle-induced potentiometric biosensing of NADH at copper ion-selective electrodes
    Chumbimuni-Torres, Karin Y.
    Wang, Joseph
    ANALYST, 2009, 134 (08) : 1614 - 1617
  • [6] Fullerene-based delivery systems
    Kazemzadeh, Houman
    Mozafari, Masoud
    DRUG DISCOVERY TODAY, 2019, 24 (03) : 898 - 905
  • [7] STABILITY OF FULLERENE-BASED SYSTEMS
    TOMANEK, D
    WANG, Y
    RUOFF, RS
    JOURNAL OF PHYSICS AND CHEMISTRY OF SOLIDS, 1993, 54 (12) : 1679 - 1684
  • [8] Overview of fullerene-based superconductors
    Saito, S
    Buntar, V
    PROCEEDINGS OF THE SYMPOSIUM ON RECENT ADVANCES IN THE CHEMISTRY AND PHYSICS OF FULLERENES AND RELATED MATERIALS, VOL 3, 1996, 96 (10): : 420 - 422
  • [9] Potentiometric Performance of Silver Ion-Selective Electrodes Based on Tridentate Schiff Base Derivatives
    Masato Ueda
    Takahiro Saito
    Keiichi Fujimori
    Takayo Moriuchi
    Yasuhiko Shibutani
    Analytical Sciences, 2004, 20 : 1649 - 1653
  • [10] Potentiometric performance of silver ion-selective electrodes based on tridentate Schiff base derivatives
    Ueda, M
    Saito, T
    Fujimori, K
    Moriuchi, T
    Shibutani, Y
    ANALYTICAL SCIENCES, 2004, 20 (12) : 1649 - 1653