Potentiometric biosensors for cholinesterase inhibitor analysis based on mediatorless bioelectrocatalysis

被引:38
|
作者
Ghindilis, AL [1 ]
Morzunova, TG [1 ]
Barmin, AV [1 ]
Kurochkin, IN [1 ]
机构
[1] RES CTR MOL DIAGNOST & THERAPY,DEPT BIOSENSORS,MOSCOW 113149,RUSSIA
来源
BIOSENSORS & BIOELECTRONICS | 1996年 / 11卷 / 09期
关键词
mediatorless bioelectrocatalysis; butyrylcholinesterase; choline oxidase; peroxidase; inhibitor cholinesterase; biosensor;
D O I
10.1016/0956-5663(96)89436-X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A potentiometric method for cholinesterase inhibitor analysis based on mediatorless bioelectrocatalysis has been developed. The method includes coimmobilization of three enzymes, butyrylcholinesterase, choline oxidase and peroxidase, on composite carbon electrodes. Catalytic hydrolysis of butyrylcholine and subsequent catalytic oxidation of choline result in the formation of hydrogen peroxide leads to a shift in the electrode potential. The detection limit for trichlorfon analysis is 2 x 10(-13) M. Electrodes remain stable for at least 4 weeks when stored at 277 K. (C) 1996 Elsevier Science Limited.
引用
收藏
页码:873 / 880
页数:8
相关论文
共 50 条
  • [1] Potentiometric biosensors for cholinesterase inhibitor analysis based on mediatorless bioelectrocatalysis
    Ghindilis, Andrey L.
    Morzunova, Tatyana G.
    Barmin, Anatoly V.
    Kurochkin, IIya N.
    Biosensors and Bioelectronics, 1996, 11 (09): : 873 - 880
  • [2] Environmental biosensors based on mediatorless bioelectrocatalysis
    Atanasov, P
    Espinosa, M
    Wilkins, E
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1999, 217 : U790 - U790
  • [3] GLUCOSE POTENTIOMETRIC ELECTRODES BASED ON MEDIATORLESS BIOELECTROCATALYSIS - A NEW APPROACH
    GHINDILIS, AL
    KUROCHKIN, IN
    BIOSENSORS & BIOELECTRONICS, 1994, 9 (4-5): : 353 - 357
  • [4] POTENTIOMETRIC ENZYME ELECTRODES BASED ON SUBSTRATE RECYCLING AND MEDIATORLESS BIOELECTROCATALYSIS
    GHINDILIS, AL
    MAKOWER, A
    SCHELLER, FW
    SENSORS AND ACTUATORS B-CHEMICAL, 1995, 28 (02) : 109 - 112
  • [5] The use of polyethyleneimine for fabrication of potentiometric cholinesterase biosensors
    Reybier, K
    Zairi, S
    Jaffrezic-Renault, N
    Fahys, B
    TALANTA, 2002, 56 (06) : 1015 - 1020
  • [6] Development Perspective of Bioelectrocatalysis-Based Biosensors
    Adachi, Taiki
    Kitazumi, Yuki
    Shirai, Osamu
    Kano, Kenji
    SENSORS, 2020, 20 (17) : 1 - 21
  • [7] EQCN based cholinesterase biosensors
    Halamek, J.
    Teller, C.
    Makower, A.
    Fournier, D.
    Scheller, F. W.
    ELECTROCHIMICA ACTA, 2006, 51 (24) : 5174 - 5181
  • [8] Cholinesterase-based biosensors
    Stepankova, Sarka
    Vorcakova, Katarina
    JOURNAL OF ENZYME INHIBITION AND MEDICINAL CHEMISTRY, 2016, 31 : 180 - 193
  • [9] Progress of Biosensors Based on Cholinesterase Inhibition
    Pohanka, Miroslav
    Musilek, Kamil
    Kuca, Kamil
    CURRENT MEDICINAL CHEMISTRY, 2009, 16 (14) : 1790 - 1798
  • [10] Biosensors based on cholinesterase for detection of pesticides
    Skladal, P