THE COMPARISON OF INTRAOCULAR PRESSURE MEASUREMENT BY GOLDMANN APPLANATION TONOMETER AND NON-CONTACT AIR PUFF TONOMETER: A CROSS-SECTIONAL RESEARCH

被引:0
|
作者
Arooj, Bushra [1 ]
Nadeem, Asmarah [1 ]
Ali, Sobia [1 ]
机构
[1] Lahore Gen Hosp, Lahore, Pakistan
来源
关键词
Tonometry; Glaucoma; Goldmann Applanation Tonometer and Air Puff Tonometer;
D O I
10.5281/zenodo.2526307
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Objective: The aim of this particular research was to determine the accuracy and frequency of intraocular pressure which measured with the help of an Air Puff (non-contact tonometer); moreover, we also confirmed the same by Goldmann applanation tonometer. Material and methods: Our research design was cross-sectional and it was carried out at Ophthalmology Department of Mayo Hospital, Lahore (February to July 2017) on a total of 240 patients. All the patients were in the age bracket of (10 - 70) years including males and females. The selection process included those patients who visited Eye OPD for regular intraocular pressure, refraction, glaucoma, cataract surgery and suspected glaucoma. A complete ocular assessment was mandatory for every individual participating in the research. Results: In the age bracket of (10 - 70) years the mean age was (43.844 +/- 15.434) years and the values of mean IOP was for Goldmann Applanation Tonometer as (18.92 +/- 8.852) mmHg and for Air Puff Tonometer as (21.463 +/- 9.456) mmHg. The different measurement ranges for Air-Puff Tonometer and Goldmann Applanation Tonometer was respectively (10 - 54) mmHg and (11 - 58) mmHg. Conclusion: In order to measure intraocular pressure, the method of Air puff tonometer is non-contact and quick. Air Puff tonometer is effective for screening purposes; whereas, the intraocular pressure measurements are accurately measured through Goldmann applanation tonometer.
引用
收藏
页码:16875 / 16879
页数:5
相关论文
共 50 条
  • [31] Influence of punctate superficial keratitis on intraocular pressure measured with Goldmann applanation tonometer and noncontact tonometer
    Shimizu, Daisuke
    Yamamoto, Shuichi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [32] Comparison of the Proview pressure phosphene tonometer performed by the patient and examiner with the Goldmann applanation tonometer
    Danesh-Meyer, HV
    Niederer, R
    Gaskin, BJ
    Gamble, G
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2004, 32 (01): : 29 - 32
  • [33] Comparison of three methods of tonometry in normal subjects: Goldmann applanation tonometer, non-contact airpuff tonometer, and Tono-Pen XL
    Yilmaz, Ihsan
    Altan, Cigdem
    Aygit, Ebru Demet
    Alagoz, Cengiz
    Baz, Okkes
    Ahmet, Sibel
    Urvasizoglu, Semih
    Yasa, Dilek
    Demirok, Ahmet
    CLINICAL OPHTHALMOLOGY, 2014, 8 : 1069 - 1073
  • [34] Dynamic Contour Tonometer and Goldmann Applanation Tonometer Performance in a Developing World Setting: Intraocular Pressure Measurement Acquisition and Precision
    Cheng, Jason
    Salam, Tahrina
    Russell, Paul J.
    Heath, David G.
    Kotecha, Aachal
    JOURNAL OF GLAUCOMA, 2013, 22 (09) : 736 - 739
  • [35] Comparison of intraocular pressure measurements with the tono-pen, goldmann applanation tonometer, and noncontact tonometer in nonglaucomatous pseudophakic children
    Yalcin, Sibel Oskan
    Kaplan, Aysin Tuba
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [36] Comparison of Disposable Goldmann Applanation Tonometer, ICare ic100, and Tonopen XL to Standards of Care Goldmann Nondisposable Applanation Tonometer for Measuring Intraocular Pressure
    Wong, Benny
    Parikh, Deep
    Rosen, Lisa
    Gorski, Matthew
    Angelilli, Allison
    Shih, Carolyn
    JOURNAL OF GLAUCOMA, 2018, 27 (12) : 1119 - 1124
  • [37] Comparison of air puff tonometer with goldman applanation tonometer in different corneal thickness measurements
    Kousar, Rubina
    Rahat-ul-Ain
    Kalsoom, Tahira
    BIOSCIENCE RESEARCH, 2022, 19 (01): : 706 - 712
  • [38] Evaluation of the New Digital Goldmann Applanation Tonometer for Measuring Intraocular Pressure
    Sakaue, Yuta
    Ueda, Jun
    Seki, Masaaki
    Tanaka, Takayuki
    Togano, Tetsuya
    Yoshino, Takaiko
    Fukuchi, Takeo
    JOURNAL OF OPHTHALMOLOGY, 2014, 2014
  • [39] Comparison of IOP-measurements obtained by the non-contact tonometer AT555 and Goldmann applanation tonometry
    Mueller-Holz, M
    Schmidt, E
    Boehm, AG
    Pillunat, LE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [40] Clinical comparison of ocular blood flow tonometer, tonopen, and Goldmann applanation tonometer for measuring intraocular pressure in postkeratoplasty eyes
    Rao, VJ
    Gnanaraj, L
    Mitchell, KW
    Figueiredo, FC
    CORNEA, 2001, 20 (08) : 834 - 838