THE COMPARISON OF INTRAOCULAR PRESSURE MEASUREMENT BY GOLDMANN APPLANATION TONOMETER AND NON-CONTACT AIR PUFF TONOMETER: A CROSS-SECTIONAL RESEARCH

被引:0
|
作者
Arooj, Bushra [1 ]
Nadeem, Asmarah [1 ]
Ali, Sobia [1 ]
机构
[1] Lahore Gen Hosp, Lahore, Pakistan
来源
关键词
Tonometry; Glaucoma; Goldmann Applanation Tonometer and Air Puff Tonometer;
D O I
10.5281/zenodo.2526307
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Objective: The aim of this particular research was to determine the accuracy and frequency of intraocular pressure which measured with the help of an Air Puff (non-contact tonometer); moreover, we also confirmed the same by Goldmann applanation tonometer. Material and methods: Our research design was cross-sectional and it was carried out at Ophthalmology Department of Mayo Hospital, Lahore (February to July 2017) on a total of 240 patients. All the patients were in the age bracket of (10 - 70) years including males and females. The selection process included those patients who visited Eye OPD for regular intraocular pressure, refraction, glaucoma, cataract surgery and suspected glaucoma. A complete ocular assessment was mandatory for every individual participating in the research. Results: In the age bracket of (10 - 70) years the mean age was (43.844 +/- 15.434) years and the values of mean IOP was for Goldmann Applanation Tonometer as (18.92 +/- 8.852) mmHg and for Air Puff Tonometer as (21.463 +/- 9.456) mmHg. The different measurement ranges for Air-Puff Tonometer and Goldmann Applanation Tonometer was respectively (10 - 54) mmHg and (11 - 58) mmHg. Conclusion: In order to measure intraocular pressure, the method of Air puff tonometer is non-contact and quick. Air Puff tonometer is effective for screening purposes; whereas, the intraocular pressure measurements are accurately measured through Goldmann applanation tonometer.
引用
收藏
页码:16875 / 16879
页数:5
相关论文
共 50 条
  • [1] COMPARISON OF INTRAOCULAR PRESSURE MEASURED WITH GOLDMANN APPLANATION TONOMETER AND NON-CONTACT AIR-PUFF TONOMETER
    Mahsud, Hidayatullah
    Saleem, Muhammad Wali
    Muhammad, Rafiq
    Saleem, Muhammad
    Ayaz, Mirqad
    GOMAL JOURNAL OF MEDICAL SCIENCES, 2016, 14 (02): : 63 - 66
  • [2] Study of Accuracy of Intraocular Pressure measured by non-contact (air puff) Tonometer confirmed by Goldmann Applanation Tonometer
    Dibaji, Mohammad
    Shaikh, Rehan Moinuddin
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2016, 10 (03): : 972 - 974
  • [3] COMPARATIVE MEASUREMENTS OF INTRAOCULAR-PRESSURE WITH THE NON-CONTACT TONOMETER AND THE GOLDMANN APPLANATION TONOMETER
    LANGMANN, G
    SCHUHMANN, G
    SCHWAIGER, W
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1985, 187 (05) : 345 - 347
  • [4] Comparison of intraocular pressure measurements obtained by icare pro tonometer, non-contact tonometer and Goldmann applanation tonometer in healthy individuals
    Duran, M.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2023, 46 (10): : 1195 - 1203
  • [5] Comparative evaluation of intraocular pressure with an air-puff tonometer versus a Goldmann applanation tonometer
    Farhood, Qasim K.
    CLINICAL OPHTHALMOLOGY, 2013, 7 : 23 - 27
  • [6] COMPARISON OF A NEW NON-CONTACT TONOMETER WITH GOLDMANN APPLANATION
    MOSELEY, MJ
    EVANS, NM
    FIELDER, AR
    EYE, 1989, 3 : 332 - 337
  • [7] Agreement of intraocular pressure measurement with Corvis ST, non-contact tonometer, and Goldmann applanation tonometer in children with ocular hypertension and related factors
    Li, Hou-Gang
    Chen, Yan-Hui
    Lin, Fang
    Li, Si-Yu
    Liu, Qing-Hua
    Yin, Chun-Ge
    Chen, Xi-Yue
    Zhang, Xin-Jie
    Qu, Yue
    Hui, Yan-Nian
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2023, 16 (10) : 1601 - 1607
  • [8] Influence of Corneal Biomechanical Properties on Intraocular Pressure Differences Between an Air-Puff Tonometer and the Goldmann Applanation Tonometer
    Tranchina, Laura
    Lombardo, Marco
    Oddone, Francesco
    Serrao, Sebastiano
    Lomoriello, Domenico Schiano
    Ducoli, Pietro
    JOURNAL OF GLAUCOMA, 2013, 22 (05) : 416 - 421
  • [9] A clinical comparison of the Xpert non-contact tonometer with the Goldmann applanation tonometer after penetrating keratoplasty
    Lisle, C
    Ehlers, N
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2000, 78 (02): : 211 - 215
  • [10] A Comparative Study Between the Goldmann Applanation Tonometer and the Non-Contact Air-Puff Tonometer (Huvitz HNT 7000) in Normal Eyes
    Stock, Ricardo Alexandre
    Stroher, Carine
    Sampaio, Rodrigo Rosa
    Mergener, Rafael Andre
    Bonamigo, Elcio Luiz
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 445 - 451