Design of a chilled-water storage unit for solar air-conditioning

被引:1
|
作者
Serag-Eldin, M. A. [1 ]
机构
[1] Amer Univ, Sch Sci & Engn, Mech Engn Dept, AUC Ave,New Cairo,POB 74, New Cairo, Egypt
关键词
chilled-water storage; thermal energy storage; solar air-conditioning; green-buildings; heat infiltration;
D O I
10.1080/14786451.2013.774399
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Solar powered air-conditioning requires some form of thermal energy storage in order to continuously balance energy supply and demand. The current paper is concerned with energy storage in the form of stored chilled water produced by a chiller during times when supply is more than demand. A new multi-tank storage unit design is presented and evaluated employing a specially developed mathematical model and computational code that predicts the various modes of heat transfer occurring within the storage unit. The computational code is both efficient and accurate; it is presented and employed to investigate the effect of various operating parameters and design options on performance. It is revealed that employing only modest insulation, the daily heat penetration is around 2% of the daily stored cooling-capacity. This loss is much lower than the losses involved in other forms of energy storage, such as battery storage, and expected to be cheaper and more environmentally friendly.
引用
收藏
页码:385 / 405
页数:21
相关论文
共 50 条
  • [1] A New Air-conditioning System with Chilled Water Storage
    Lin, Hu
    Li, Xinhong
    Cheng, Pengsheng
    Xu, Bugong
    [J]. PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING II, PTS 1-4, 2013, 405-408 : 2964 - +
  • [2] Experimental investigation on the performance of chilled-water air conditioning unit using alumina nanofluids
    Ahmed, M. Salem
    Hady, Mohamed R. Abdel
    Abdallah, G.
    [J]. THERMAL SCIENCE AND ENGINEERING PROGRESS, 2018, 5 : 589 - 596
  • [3] Performance evaluation of solar-assisted air-conditioning system with chilled water storage (CIESOL building)
    Rosiek, Sabina
    Batlles Garrido, Francisco Javier
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2012, 55 : 81 - 92
  • [4] Energy Consumption Comparison of Large-scale Air-conditioning System With Different Temperature of Chilled-Water
    Jiang, Xiaojiang
    Xiao, Jianren
    Li, Xingyou
    [J]. 10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 2100 - 2104
  • [5] Chilled energy storage for air-conditioning system of buildings
    Shu, Xiaojian
    [J]. FRONTIERS OF MANUFACTURING AND DESIGN SCIENCE IV, PTS 1-5, 2014, 496-500 : 1020 - 1023
  • [6] ECOMOMIC ASSESSMENT OF CHILLED WATER THERMAL STORAGE AND CONVENTIONAL AIR-CONDITIONING SYSTEMS
    Sebzali, M. J.
    Ameer, B.
    Hussain, H. J.
    [J]. TERRAGREEN 2012: CLEAN ENERGY SOLUTIONS FOR SUSTAINABLE ENVIRONMENT (CESSE), 2012, 18 : 1485 - 1495
  • [7] Study on a new optimum design method for the air-conditioning chilled water system
    Yin, P
    Jiang, CX
    [J]. PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 1547 - 1554
  • [8] Comparison of energy performance and economics of chilled water thermal storage and conventional air-conditioning systems
    Sebzali, M. J.
    Ameer, B.
    Hussain, H. J.
    [J]. ENERGY AND BUILDINGS, 2014, 69 : 237 - 250
  • [9] Study on chilled energy storage of air-conditioning system with energy saving
    Lin, Hu
    Li, Xin-hong
    Cheng, Peng-sheng
    Xu, Bu-gong
    [J]. ENERGY AND BUILDINGS, 2014, 79 : 41 - 46
  • [10] A Virtual Chilled-Water Flow Meter Development at Air Handling Unit Level
    Swamy, Atul
    Song, Li
    Wang, Gang
    [J]. ASHRAE TRANSACTIONS 2012, VOL 118, PT 1, 2012, 118 : 1013 - 1020