Chilled energy storage for air-conditioning system of buildings

被引:1
|
作者
Shu, Xiaojian [1 ]
机构
[1] Ningbo City Coll Vocat Technol, Environm Fac, Ningbo 315100, Zhejiang, Peoples R China
关键词
air-conditioning system of buildings; chilled energy; storage;
D O I
10.4028/www.scientific.net/AMM.496-500.1020
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Due to higher energy consumption for air-condition system and higher energy cost for building, the combination between peak-valley power price and chilled energy storage is provided and paid more and more attention. This paper introduced main chilled energy storage technologies and analyzed their economic performance, chilled water storage and ice storage both have good performance, but they fit for difference conditions, for chilled water storage, it doesn't need to add chiller for below zero temperature and fits for energy saving reform, and ice storage can meet the need of new air-conditioning system, which supplies a new application direction for energy cost saving operation in building.
引用
收藏
页码:1020 / 1023
页数:4
相关论文
共 50 条
  • [1] Study on chilled energy storage of air-conditioning system with energy saving
    Lin, Hu
    Li, Xin-hong
    Cheng, Peng-sheng
    Xu, Bu-gong
    [J]. ENERGY AND BUILDINGS, 2014, 79 : 41 - 46
  • [2] A New Air-conditioning System with Chilled Water Storage
    Lin, Hu
    Li, Xinhong
    Cheng, Pengsheng
    Xu, Bugong
    [J]. PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING II, PTS 1-4, 2013, 405-408 : 2964 - +
  • [3] Comparison of energy performance and economics of chilled water thermal storage and conventional air-conditioning systems
    Sebzali, M. J.
    Ameer, B.
    Hussain, H. J.
    [J]. ENERGY AND BUILDINGS, 2014, 69 : 237 - 250
  • [4] Modeling of an air-conditioning system in smart buildings
    Khabthani, Abir
    Chaabane, Leila
    [J]. 2015 7th International Conference on Modelling, Identification and Control (ICMIC), 2014, : 34 - 37
  • [5] Design of a chilled-water storage unit for solar air-conditioning
    Serag-Eldin, M. A.
    [J]. INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2013, 32 (05) : 385 - 405
  • [6] Solar Air-conditioning of Buildings
    Hindenburg, Carsten
    [J]. WOHLFUHLEN DURCH RAUMLUFTTECHNIK, 2010, 2091 : 133 - 141
  • [7] Energy audit and analysis of chilled water system for air conditioning of commercial buildings in Shanghai
    Wang, CQ
    Long, WD
    Ding, WT
    [J]. INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 123 - 127
  • [8] Energy Consumption Analysis of a Liquid Desiccant Air-conditioning System for Industrial Buildings
    Tang, Yidan
    Liu, Xiaohua
    [J]. 6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 551 - 558
  • [9] AIR-CONDITIONING OF OFFICE BUILDINGS
    FITZNER, K
    [J]. KALTE UND KLIMATECHNIK, 1983, 36 (04): : 158 - &
  • [10] Energy Efficiency Analysis of All-Variable Chilled Water based Air-Conditioning System
    Beniwal, Ravi
    Srivastava, Prateek
    [J]. INTERNATIONAL CONFERENCE ON TRENDS IN MATERIAL SCIENCE AND INVENTIVE MATERIALS (ICTMIM 2020), 2020, 2259